Home›Products ›Concealed Vertical FCU ›DeLENG 4-Pipe Concealed Vertical Fan Coil Unit (Dual In / Dual Out, Independent Heating & Cooling)

DeLENG 4-Pipe Concealed Vertical Fan Coil Unit (Dual In / Dual Out, Independent Heating & Cooling)

DELENG HVAC · Direct from our Dezhou factory

DeLENG 4-Pipe Concealed Vertical Fan Coil Unit
(Dual Inlet / Dual Outlet, Independent Heating & Cooling)

Three rows of chilled water coil plus one row of hot water coil, dual water inlets and outlets with fully independent heating and cooling, three discharge styles (angled, flat, direct), models FP-34 to FP-238, pure copper hydrophilic fin coil and copper-core motor, galvanised steel casing for concealed floor installation.

3+1 four-pipeIndependent heating / cooling3 discharge styles3 cold + 1 hot rowConcealed vertical
DeLENG 4-pipe concealed vertical fan coil unit, dual inlet and outlet

Product introduction

The DeLENG 4-pipe (3+1) concealed vertical fan coil unit is equipped with three rows of chilled water coil plus one row of hot water coil. Through dual water inlets and outlets, the chilled and hot water circulate completely independently — at any moment the unit can cool only, heat only, or deliver chilled and hot water to different zones at the same time, which removes the waiting and changeover of a conventional two-pipe system.

The unit is floor-standing for concealed installation, with a uniform body width of 225 mm and height of 600 mm; length runs from 620 mm (FP-34) to 1920 mm (FP-238) and the recommended floor area covers 5–60 m². Three discharge forms are available — angled, flat and direct — to suit different ceiling and floor-supply arrangements.

Core configuration: pure copper tubes with hydrophilic aluminium fins for efficient heat exchange, three-speed copper-core motor for stable low-noise running, galvanised steel casing for durability, standard Rc 3/4 water connections, maximum working pressure 1.6 MPa, power supply AC220V/50Hz, built to GB/T 19232-2019.

Service hotline: 0534-2555668

Product photos · dual inlets and outlets, independent heating and cooling

DeLENG 4-pipe concealed vertical fan coil unit, dual water circuits

Complete unit · separate inlet and outlet for each water circuit

Angled, flat and direct discharge versions of the concealed vertical unit

Angled / flat / direct discharge — three styles available

Why choose the 4-pipe concealed vertical fan coil unit

Independent heating and cooling · dual inlets and outlets · concealed vertical · efficient heat exchange

F

Four-pipe, independent

Three rows of chilled water coil plus one row of hot water coil; cooling and heating run on separate water circuits, so both are available at the same time with no seasonal changeover.

D

Dual inlet / dual outlet

Four DN20 brass connections are grouped together: chilled water in/out and hot water in/out form two independent circuits that do not interfere.

C

Concealed vertical

Floor-standing and hidden under a window sill or in a corner wall niche, it takes no ceiling space and suits building refurbishment and rooms without a ceiling void.

P

Pure copper coil

Copper tubes with hydrophilic aluminium fins, fin-collar mechanical tube expansion: high heat exchange efficiency, durable and leak-free.

4-pipe (3+1) fan coil unit technical performance parameters

Standard GB/T 19232-2019 · measured without return-air box

Parameter Item FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Airflow m³/h High 340 510 680 850 1020 1360 1700 2040 2380
Medium 255 383 510 638 765 1020 1275 1530 1785
Low 170 255 340 425 510 680 850 1020 1190
Cooling capacity W High 1800 2700 3600 4500 5400 7200 9000 10800 12600
Medium 1440 2160 2880 3600 4320 5760 7200 8640 10080
Low 1170 1755 2340 2925 3510 4680 5850 7020 8190
Heating capacity W High 2700 4050 5400 6750 8100 10800 13500 16200 18900
Medium 2160 3240 4320 5400 6480 8640 10800 12960 15120
Low 1755 2633 3510 4388 5265 7020 8775 10530 12285
Input power W 12 Pa 37 52 62 76 96 134 152 189 228
30 Pa 44 59 72 87 108 156 174 212 253
50 Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 12 Pa 37 39 41 43 45 46 48 50 52
30 Pa 40 42 44 46 47 48 50 52 54
50 Pa 42 44 46 47 49 50 52 54 56
Water flow t/h — 0.39 0.55 0.70 0.82 0.91 1.34 1.59 1.80 2.07
Water resistance kPa — 12 16 20 23 26 28 32 38 42
Weight kg (FP-LA) 18 21 23 24 26 39 44 47 56
Test conditions: 1) Cooling capacity: entering air dry bulb 27°C / wet bulb 19.5°C, entering water 7°C, water temperature difference 5°C. 2) Heating capacity: entering air dry bulb 21°C, entering water 60°C. 3) The unit has three rows of chilled water coil and one row of hot water coil. 4) Power supply AC220V/50Hz, water connections Rc 3/4, condensate R2 3/4, maximum working pressure 1.6 MPa.

Overall dimensions and recommended floor area

Width 225 mm and height 600 mm are common to all models; length increases with model

Model L (mm) W (mm) H (mm) Area (m²)
34LA 620 225 600 5—10
51LA 740 225 600 10—15
68LA 810 225 600 15—20
85LA 940 225 600 20—25
102LA 1060 225 600 25—30
136LA 1260 225 600 30—40
170LA 1520 225 600 40—50
204LA 1720 225 600 50—55
238LA 1920 225 600 55—60
Overall dimensions of the concealed vertical fan coil unit

Selection and customisation

This is a standardised 4-pipe (3+1) concealed vertical fan coil unit with nine standard models from FP-34 to FP-238. Non-standard versions can be built to project requirements: special lengths, other discharge directions, an added filter, a motorised two-way valve or thermostat, a longer condensate pipe and other options.

Selection advice: estimate the cooling load from the room area (about 150–200 W/m²) and pick one size up from the table above; for ceilings higher than 3.5 m, west-facing rooms or large glazed facades, go one size further. Send us your project drawings and DeLENG technical staff will check the selection — call 0534-2555668.

Applications

O

Office buildings

Independent cooling and heating by zone

H

Hotels

Concealed installation leaves the fit-out untouched

H

Hospital wards

Clean, quiet, cooling and heating at the same time

M

Malls and clubs

Large cooling capacity across many models

FAQ

Q: What is the difference between a 3+1 four-pipe unit and a normal two-pipe fan coil unit?

A: A normal two-pipe unit has only one supply and one return line, so it can only heat or cool, one at a time. The 3+1 unit has three rows of chilled water coil plus one row of hot water coil with separate water circuits, so it can cool and heat at the same moment without a seasonal changeover — ideal for projects that need air conditioning in spring and autumn as well.

Q: How do I choose between angled, flat and direct discharge?

A: Angled discharge suits a short duct feeding air upwards; flat discharge feeds horizontally straight from a top outlet; direct discharge suits floor-level supply or a vertical duct. The choice follows the ceiling type and outlet position; DeLENG technical staff can help you decide.

Q: What about price and warranty?

A: We supply direct from the factory, so the price depends on model and options. Call 0534-2555668 for a quotation. The complete unit carries a three-year warranty and the pure copper motor five years.

Third-party test report for this series (CMA / CNAS)
Nine models, FP-34WA to FP-238WA, tested by Guangdong Junxin Testing and the Jiangsu Institute of Product Quality Supervision and Inspection to GB/T 19232-2019 and related standards — all tested items pass. Ready for project approval and tender submissions.

Download test report →

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need 4-Pipe Concealed Vertical Fan Coil Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top