Factory testing, production processes, project deliveries and the practical issues customers ask us about most.

Four custom cooling coils left our Dezhou workshop in late October for a HVAC contractor in Suzhou, Jiangsu. The coils are used as two stacked pairs, four units in total, each with its own length, height a…

A batch of 337 floor-ceiling (four-pipe) fan coil units left our Dezhou workshop for a government office building in Dawukou District, Shizuishan, Ningxia. The order followed a comparison of three supplier…

An industrial warm-air heater is a simple machine until something goes wrong on site — then it is the machine that stopped a production line in winter. Our rule is that every unit is run before it is packe…

Two cooling coils can use identical copper tube, identical aluminium fin and identical face area and still transfer noticeably different amounts of heat. The difference is almost always the joint between t…

A fan coil unit that leaks rarely leaks on the day it is installed. It leaks in the first heating season, above a ceiling, in a room where nobody is watching. That is why the pressure test is a production …

Paper mills, dyeing plants and electroplating shops ask the same two questions: how long will a standard coil last in this air, and do we really need the anti-corrosion treatment? Both have a straight answ…

Two or three years after installation the complaint is always the same: airflow has dropped, the rooms feel stuffy, the machine must be broken. Eight calls out of ten it is the filter, not the machine.Airf…

Water on a ceiling is almost never a manufacturing fault. In our experience it comes from one of five installation issues, and four of them can be fixed before the ceiling is closed.1. Condensate drain wit…

Short answer: for a while, yes. As a permanent arrangement with the outlet aimed at a workstation, no — and the reason is not the heater, it is the person standing in front of it.What a long exposure actua…

A frozen coil is one of the more expensive failures in an air handling system: the tube can split, and the repair usually means removing the coil from the unit. Frost appears for a small number of reasons,…

The instinct at selection time is that more fresh air must mean better air. In practice an oversized ventilator costs more to buy, more to run, and can make the room less comfortable than a correctly sized…

Most fan coil selection questions that arrive by e-mail are missing the same three numbers. Fill those in and the answer comes back in one round instead of five.1. Sensible and latent load, or the room dat…

Noise is the complaint we hear most often on fan coil projects, and the first assumption is always that the unit is at fault. After twenty years of factory and site work, the split is roughly twenty percen…