Home›Products ›Concealed Horizontal FCU ›DeLENG Concealed Horizontal Fan Coil Unit with Condensate Lift Pump

DeLENG Concealed Horizontal Fan Coil Unit with Condensate Lift Pump

DELENG HVAC · Direct from our Dezhou factory

DeLENG Concealed Horizontal Fan Coil Unit with Condensate Lift Pump

Concealed horizontal unit with a condensate lift pump and float switch — condensate is pumped away automatically, so drainage is never a problem. Hydrophilic fins with pure copper tubes for efficient heat exchange, all-copper motor windings, and nine models from 34WA to 238WA covering 5–60 m².

Condensate lift pumpFloat switchHydrophilic copper tubesAll-copper motor34WA–238WA
DeLENG concealed horizontal fan coil unit with condensate lift pump

Product overview

The DeLENG concealed horizontal fan coil unit with lift pump is built around a condensate lift pump plus a float-type water level switch, which starts the pump automatically to discharge condensate. It uses a hydrophilic-fin coil with pure copper tubes for high heat-exchange efficiency; the motor windings are all copper for stable, powerful running; and the casing is made of quality galvanised steel sheet for corrosion resistance.

Models run from 34WA (750×455×250 mm, 5–10 m²) and 51WA (850×455×250 mm, 10–15 m²) up to 238WA (2050×455×250 mm, 55–60 m²), with motor power from 10 W to 60 W; left-hand and right-hand installation are both supported.

Service hotline: +86 534 2555668

Key features · why choose the DeLENG lift-pump fan coil unit

Condensate lift pump · hydrophilic copper coil · all-copper motor · left / right hand

C

Condensate lift pump

Lift pump plus float switch discharges condensate automatically — no drainage problem.

H

Hydrophilic copper coil

Hydrophilic fins with a pure copper tube coil for efficient heat exchange.

A

All-copper motor

All-copper windings for stable, powerful running.

L

Left / right hand

Left-hand and right-hand installation both supported.

Product structure · the lift-pump design

Concealed horizontal lift-pump fan coil unit — overall view and condensate lift pump
Linked control board — fan and lift pump run together, automatic interlock
Condensate lift pump detail — high head, easy condensate discharge
Float-type water level switch — trips the pump, automatic drainage control

Concealed horizontal fan coil unit technical data (GB/T 19232-2003)

Lift-pump version — same ratings as the standard concealed horizontal range

Cooling condition: entering air dry bulb 27 °C / wet bulb 19.5 °C, entering water 7 °C with 5 °C temperature difference. Heating condition: entering air dry bulb 21 °C, entering water 60 °C, hot-water flow as per the cooling condition. Every unit is pressure tested at 2.0 MPa; maximum working pressure 1.6 MPa.
Performance Model FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Rated air volume
m³/h
High 340 510 680 850 1020 1360 1700 2040 2380
Medium 260 390 510 640 770 1020 1280 1530 1790
Low 170 260 340 430 510 680 850 1020 1190
Rated cooling capacity kW High 1.98 2.8 3.87 4.58 5.42 7.38 9.08 11.1 12.9
Rated heating capacity kW High 3.39 4.5 6.35 7.45 9.22 12.4 16.3 19.5 20.2
Input power W 12Pa 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 12Pa 37 39 41 43 45 46 48 50 52
30Pa 40 42 44 46 47 48 50 52 54
50Pa 42 44 46 47 49 50 52 54 56
Water flow kg/h — 350 510 660 800 980 1280 1600 1920 2230
Water resistance kPa — 30 30 30 30 40 40 40 40 50
Weight kg WA 17 18 19 22 26 39 43 49 52
With return-air box 20 22 23 27 30 44 48 54 58
Water connection 3/4" female thread (forged brass header)
Condensate connection 3/4" male thread
Power supply Single phase 220V / 50Hz
Selection notes: water connections are available left-hand or right-hand (facing the supply outlet, left-hand means the connections sit on the left). The lift-pump version suits long drainage runs or sites where gravity drainage is not possible. For selection please give us the space conditions — DeLENG, +86 534 2555668.

Dimensions

Concealed horizontal, rear return series (FP-WA)

Dimension drawing — concealed horizontal fan coil unit, rear return
Dimensions (mm) FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
A (unit length) 750 850 950 1050 1150 1350 1650 1850 2050
B (supply outlet length) 460 580 650 780 900 1100 1350 1550 1750
C (hanger hole spacing) 490 610 680 810 930 1130 1380 1580 1780

2. Concealed horizontal, bottom return series (FP-WA bottom return)

Dimension drawing — concealed horizontal fan coil unit, bottom return
Dimensions (mm) FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
A (unit length) 750 850 950 1050 1150 1350 1650 1850 2050
B (supply outlet length) 460 580 650 780 900 1100 1350 1550 1750
C (hanger hole spacing) 490 610 680 810 930 1130 1380 1580 1780

Applications · concealed heating and cooling with a lift pump

A

Automatic drainage

Solves condensate drainage problems

C

Concealed installation

Recessed into the ceiling void

C

Commercial

Terminal units for commercial premises

R

Residential

Heating and cooling for homes

FAQ

Q: What does the lift pump do?

A: A float-type water level switch trips the pump to discharge condensate automatically, so drainage works even where the pipe cannot be given a fall.

Q: What is the model range?

A: 34WA to 238WA, from 750×455×250 mm to 2050×455×250 mm, covering 5–60 m².

Q: Which side can the water connections be on?

A: Left-hand or right-hand installation is supported, with the connections on the corresponding side of the supply outlet.

Third-party test reports for this range (CMA / CNAS)
Nine models from FP-34WA to FP-238WA, tested by Guangdong Junxin Testing and the Jiangsu Provincial Institute of Product Quality Supervision and Inspection against GB/T 19232-2019 and related standards; the conclusion is “all tested items passed”. Ready to use for project submission and tender documentation.

Download test reports →

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need Concealed Horizontal Fan Coil Unit with Condensate Lift Pump?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668