A thermostatic actuator in the neck senses the supply-air temperature and changes the discharge angle automatically. Horizontal discharge in summer, angled-down discharge in winter — no power supply, energy-saving. Sizes φ200~φ630, aluminium sheet.

The DeLENG DL-W thermostatic spherical jet nozzle has a thermostatic actuator in the neck, which senses the supply-air temperature and drives the inner nozzle to change the discharge angle. When the summer supply air is 17°C or below the jet leaves horizontally; when the winter supply air is 27°C or above the jet is directed downwards. This covers the supply requirements of different winter conditions.
The thermostatic actuator needs no manual adjustment, power supply or electrical controls: energy-saving, environmentally friendly, stable in performance, easy to install and maintenance-free. Material: aluminium sheet. Widely used for air supply in large open spaces.
Sales line: 0534-2555668
Self-adjusting angle · No wiring, no power · Stable performance · Maintenance-free
The thermostatic actuator needs no power: it senses the air temperature and sets the discharge direction automatically.
Horizontal discharge in summer, angled-down discharge in winter, switched automatically with the temperature.
Standard ceiling installation with no wiring or commissioning: saves labour and time.
A purely mechanical thermostatic element with no motor and no power supply — maintenance-free in long-term use.

v>
| Model | Nozzle velocity (m/s) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| φ200 | Air volume (m³/h) | 111 | 222 | 333 | 433 | 554 | 665 | 776 | 887 | 998 | 1108 |
| Outlet velocity (m/s) | 4 | 8 | 12 | 16 | 20 | 24 | 29 | 33 | 37 | 41 | |
| Total pressure loss (Pa) | 7 | 28 | 59 | 105 | 163 | 235 | 323 | 425 | 543 | 675 | |
| Throw (m) | 4.2 | 6.8 | 9.1 | 11.3 | 12.7 | 14.1 | 17 | 19.1 | 21.2 | 24 | |
| Noise dB(A) | – | – | 22 | 26 | 31 | 35 | 40 | 46 | 52 | 59 | |
| φ250 | Air volume (m³/h) | 174 | 348 | 522 | 696 | 869 | 1043 | 1217 | 1391 | 1565 | 1739 |
| Outlet velocity (m/s) | 3 | 7 | 10 | 13 | 17 | 20 | 23 | 27 | 30 | 33 | |
| Total pressure loss (Pa) | 7 | 28 | 59 | 105 | 163 | 235 | 323 | 425 | 543 | 675 | |
| Throw (m) | 5.1 | 8.5 | 11.5 | 14.2 | 16 | 17.8 | 20.5 | 24 | 26.7 | 29.3 | |
| Noise dB(A) | – | – | 23 | 27 | 32 | 37 | 42 | 48 | 53 | 61 | |
| φ315 | Air volume (m³/h) | 277 | 554 | 831 | 1108 | 1385 | 1662 | 1939 | 2216 | 2493 | 2770 |
| Outlet velocity (m/s) | 3 | 6 | 10 | 13 | 16 | 19 | 23 | 26 | 29 | 32 | |
| Total pressure loss (Pa) | 6 | 24 | 51 | 90 | 145 | 208 | 280 | 366 | 478 | 576 | |
| Throw (m) | 5 | 8.5 | 13.4 | 16.4 | 18.7 | 21.1 | 25.5 | 28.9 | 42.2 | 35.5 | |
| Noise dB(A) | – | 21 | 25 | 29 | 33 | 38 | 43 | 50 | 55 | 63 | |
| φ350 | Air volume (m³/h) | 277 | 554 | 831 | 1108 | 1385 | 1662 | 1939 | 2216 | 2493 | 2770 |
| Outlet velocity (m/s) | 3 | 6 | 10 | 13 | 16 | 19 | 23 | 26 | 29 | 32 | |
| Total pressure loss (Pa) | 6 | 24 | 51 | 90 | 145 | 208 | 280 | 366 | 478 | 576 | |
| Throw (m) | 5 | 8.5 | 13.4 | 16.4 | 18.7 | 21.1 | 25.5 | 28.9 | 32.2 | 35.5 | |
| Noise dB(A) | – | 21 | 25 | 29 | 33 | 38 | 43 | 50 | 55 | 63 | |
| φ400 | Air volume (m³/h) | 448 | 896 | 1344 | 1791 | 2239 | 2687 | 3135 | 3583 | 4031 | 4479 |
| Outlet velocity (m/s) | 3 | 6 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 | |
| Total pressure loss (Pa) | 6 | 24 | 51 | 90 | 145 | 208 | 280 | 366 | 478 | 576 | |
| Throw (m) | 6.6 | 11.3 | 16 | 20 | 23.2 | 26.4 | 30.8 | 35.2 | 39.6 | 44 | |
| Noise dB(A) | – | 23 | 28 | 33 | 36 | 41 | 45 | 52 | 58 | 66 | |
| φ500 | Air volume (m³/h) | 700 | 1400 | 2100 | 2800 | 3500 | 4200 | 4900 | 5600 | 6300 | 7000 |
| Outlet velocity (m/s) | 3 | 6 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 | |
| Total pressure loss (Pa) | 6 | 25 | 55 | 95 | 150 | 218 | 300 | 380 | 495 | 605 | |
| Throw (m) | 7.2 | 12 | 18.5 | 35 | 39 | 44 | 49 | 55 | 65 | 72 | |
| Noise dB(A) | 21 | 24 | 29 | 34 | 39 | 44 | 50 | 56 | 62 | 70 | |
| φ630 | Air volume (m³/h) | 900 | 1500 | 2200 | 2900 | 3700 | 4300 | 5100 | 5800 | 6500 | 7300 |
| Outlet velocity (m/s) | 3 | 6 | 9 | 12 | 15 | 18 | 21 | 24 | 27 | 30 | |
| Total pressure loss (Pa) | 6 | 25 | 55 | 95 | 150 | 218 | 300 | 380 | 495 | 605 | |
| Throw (m) | 7.2 | 12 | 18.5 | 35 | 39 | 44 | 49 | 55 | 65 | 72 | |
| Noise dB(A) | 21 | 24 | 29 | 34 | 39 | 44 | 50 | 56 | 62 | 70 |
* Throw is measured where the terminal velocity falls to 0.5 m/s. Selection advice: 0534-2555668
Spot supply with automatic angle change for summer and winter
Self-adjusting for comfort and energy saving
Air supply for large spaces, long throw, low noise
No power, no wiring, easy installation
A: The thermostatic type has its own temperature-sensing actuator: horizontal discharge in summer and angled-down discharge in winter, with no power supply and no electrical controls; the standard type needs manual or motorised adjustment.
A: No. It is a purely mechanical thermostatic element that adjusts the angle by thermal expansion — energy-saving and maintenance-free.
A: For air supply in large open spaces such as factory floors, shopping malls, convention centres, airports and stations, where a long throw and low noise are needed.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.