DeLENG fan coil motorised ball valves are driven by a bidirectional motor and work with the thermostat to control chilled and hot water flow precisely, adjusting the opening degree to keep HVAC system temperature in dynamic balance — energy-saving and comfortable.

The fan coil motorised ball valve is designed for precise flow control in chilled and hot water systems. Working closely with the thermostat, it responds to temperature changes in real time, controls the chilled or hot medium flow precisely and keeps room temperature constant.
A high-performance bidirectional motor delivers fast response and stable running. The thermostat samples site data continuously and sends control signals that precisely open and close the valve, setting the opening degree so that flow matches actual demand for efficient energy use.
The actuator drives the valve open and closed through metal transmission parts, for dependable quality. The product is mainly used for on/off control in HVAC, central heating and water supply systems. It consists of an actuator and a valve body; the actuator is driven by a synchronous motor — noiseless with consistent action — and has built-in travel limit switches that cut the power at fully open or fully closed positions.
The body is forged brass with a sand-blasted finish, driven by metal transmission parts, made from quality raw material with precise workmanship and thickened overall for reliable pressure resistance and durability.
Service hotline:0534-2555668
Precise regulation · bidirectional motor · thermostat interlock · energy saving
Controls chilled or hot medium flow to demand, avoiding sharp temperature swings.
A high-performance bidirectional motor gives fast response and stable running.
The thermostat sends control signals that keep the chilled or hot medium in dynamic balance.
Precise flow control keeps room temperature stable and saves energy.

| Control mode | Operating principle |
| Three-wire, single control Normally open / normally closed |
The actuator is driven by a bidirectional synchronous motor. One live wire (brown) and one neutral wire (blue) must be permanently powered; a second live wire (black) switches the normally open or normally closed circuit. Normally open type: the valve closes when the actuator is powered, and opens automatically when the power is removed. Normally closed type: the valve opens when the actuator is powered, and closes automatically when the power is removed. |
| Three-wire, two control | The actuator is driven by a bidirectional synchronous motor and uses three wires: a live wire for opening (black), a live wire for closing (brown) and a common neutral (blue). Switching between the two live wires operates a three-way or two-way switch; whichever wire is energised does the work, with 90° forward and reverse rotation. Energising the open wire opens the valve, switching to the close wire closes it, and the actuator cuts its own power when the valve reaches the end position. |
| Signal with feedback | The actuator is driven by a bidirectional synchronous motor; the open and close circuits are powered separately and the actuator cuts its own power at the end position. A voltage feedback signal is provided once the valve is fully open or closed. |
| Motor type | Synchronous motor | Nominal pressure | PN16 |
| Power cable length | 300mm | Medium temperature | 15~95℃ |
| Travel time | 15 s / 30 s | Actuator torque | 3N.M/4N.M/8N.M |
| Connection | G pipe thread | Power consumption | 6 W (only while the valve is opening) |
| Close-off differential pressure | ≤0.4MPa | Medium | Chilled or hot water, or 50% glycol solution |
| Electrical specification | (50/60Hz) 24VAC/110VAC/220VAC | ||

| Product specification | Size | Product dimensions (mm) | Kv value Mpa |
Net weight KG |
||
| H | L | L1 | ||||
| Two-way | DN15(1/2) | 127 | 51 | – | – | 0.48 |
| DN20(3/4) | 135 | 58 | – | – | 0.55 | |
| DN25(1) | 140 | 65 | – | – | 0.64 | |
| DN32(1-1/4) | 152 | 76 | – | – | 0.87 | |
| DN40(1-1/2) | 157 | 85 | – | – | 0.95 | |
| Three-way | DN15(1/2) | 127 | 56 | 43 | – | 0.54 |
| DN20(3/4) | 136 | 68 | 53 | – | 0.67 | |
| DN25(1) | 141 | 78 | 61 | – | 0.83 | |
| DN32(1-1/4) | 159 | 98 | 76 | – | 1.3 | |
| DN40(1-1/2) | 173 | 120 | 94 | – | 2.3 | |
Valve body parameters are for reference only and may change without notice; the company reserves the right of interpretation.


Quality raw material · thickened body · fine workmanship
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Motor type | Synchronous motor | Nominal pressure | PN16 |
| Power cable length | 300mm | Medium temperature | 15~95℃ |
| Travel time | 15 s / 30 s | Actuator torque | 3N.M / 4N.M / 8N.M |
| Connection | G pipe thread | Power consumption | 6 W (only while the valve is opening) |
| Close-off differential pressure | ≤0.4Mpa | Medium | Chilled or hot water, or 50% glycol solution |
| Electrical specification | (50/60Hz) 24VAC / 110VAC / 220VAC | ||
| Specification | Size | H(mm) | L(mm) | L1(mm) | Kv value (MPa) | Net weight (kg) |
|---|---|---|---|---|---|---|
| Two-way | DN15(1/2) | 127 | 51 | — | 0.48 | — |
| DN20(3/4) | 135 | 58 | — | 0.55 | — | |
| DN25(1) | 140 | 65 | — | 0.64 | — | |
| DN32(1-1/4) | 152 | 76 | — | 0.87 | — | |
| DN40(1-1/2) | 157 | 85 | — | 0.95 | — | |
| DN50(2) | 170 | 96 | — | 1.36 | — | |
| Three-way | DN15(1/2) | 127 | 56 | 43 | 0.54 | — |
| DN20(3/4) | 136 | 68 | 53 | 0.67 | — | |
| DN25(1) | 141 | 78 | 61 | 0.83 | — | |
| DN32(1-1/4) | 159 | 98 | 76 | 1.3 | — | |
| DN40(1-1/2) | 173 | 120 | 94 | 2.3 | — |
Note: dimensions and parameters are for reference only and may change without notice; the company reserves the right of interpretation.
DeLENG factory direct · photographed on site
Commercial and residential HVAC systems
Precise control of hot water flow
Offices in commercial buildings
Stable residential temperatures
A: The valve and actuator are opened and closed by the thermostat’s switching signal: two-wire control gives open/close states, three-wire control adds a common wire. Supply can be 24 VAC, 110 VAC or 220 VAC (50/60 Hz); connect to the terminals shown in the wiring diagram on this page. The control lead is a 300 mm power cable.
A: Travel time comes in 15 s and 30 s versions, and actuator torque in 3 N·m, 4 N·m or 8 N·m. Match them to valve size and the close-off differential pressure required (≤0.4 MPa): larger sizes and higher pressures call for higher torque.
A: Chilled or hot water, or 50% glycol solution, with medium temperature 15-95 ℃ and nominal pressure PN16. Widely used for on/off control of central air-conditioning water systems, heating supply/return and fan coil water circuits.
A: Two-way valves give on/off control of supply and return; three-way valves can combine or divert flow. Standard sizes include DN15 (1/2″) and DN20 (3/4″), with G pipe thread connections and power consumption of only 6 W while the valve is opening.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.