Multi-layer composite structure with 25-35 dB(A) noise reduction: galvanised steel sheet + micro-perforated mesh / fire-retardant non-woven fabric / acoustic wool. Sizes 800×400×300 to 2000×1000×800 mm, airflow 1000-20000 m³/h.

The silencer and plenum box use a multi-layer composite structure: an outer corrosion-resistant, pressure-resistant galvanised steel sheet with a smooth inner wall that lowers airflow resistance; the core layer combines micro-perforated punched mesh, environmentally friendly fire-retardant non-woven fabric and thickened acoustic wool, cancelling airflow noise across a wide band with 25-35 dB(A) attenuation.
Non-standard sizes are customisable, from 800×400×300 mm to 2000×1000×800 mm, matching airflow of 1000-20000 m³/h, working temperature of -20 ℃ to 80 ℃ and static pressure ≤ 3000 Pa. Flange joints are well sealed; heat-resistant, oil-proof and Class A fire rated.
Service hotline:0534-2555668
High-efficiency noise reduction · micro-perforated panel · galvanised steel · Class A fire rating
Acoustic wool lining with a micro-perforated panel composite: strong attenuation at mid and high frequencies, made for fan rooms and AHU rooms.
Perforated galvanised facing keeps the acoustic wool in place and widens the absorption band.
Quality galvanised steel sheet, folded and welded: corrosion-resistant, durable, pressure-tight and leak-free.
Class A non-combustible acoustic wool meets fire-code requirements, so project acceptance is straightforward.




Noise control for ventilation systems
Wide-band cancellation of airflow noise
Class A fire rating, heat resistant
Well-sealed flange joints
A: A multi-layer composite (micro-perforated punched mesh + fire-retardant non-woven fabric + thickened acoustic wool) gives wide-band attenuation, measured at 25-35 dB(A). Selection can follow the fan’s noise spectrum.
A: Yes. Standard range 800×400×300 mm to 2000×1000×800 mm, airflow 1000-20000 m³/h; built to drawing dimensions and connection orientation.
A: Working temperature -20 ℃ to 80 ℃, static pressure ≤ 3000 Pa, Class A fire rated. The galvanised outer sheet is corrosion- and pressure-resistant, suitable for AHU and duct silencer sections.
A: The silencer reduces airflow noise, while the plenum box stabilises airflow and distributes it evenly. At AHU outlets the two are often used together.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.