Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator

Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator — direct from our Dezhou factory: reliable quality and non-standard customisation, widely used in commercial projects, HVAC systems, project-specific builds and factory or commercial spaces.

High dampingLow natural frequencyEasy installationStops structure-borne noiseDirect from the factory
DeLENG DJZ series hanger spring vibration isolator

Product overview

The DJZ series hanger spring isolator is a spring mount made for suspended equipment. Built around a quality helical spring and damping structure, it offers high damping, a low natural frequency and easy installation. It absorbs and attenuates vibration from running equipment and is notably effective against structure-borne noise, so it is widely used for suspended ceiling air conditioners, supply and exhaust fans, axial fans, fresh-air units and pipework.

The DeLENG DJZ series covers a wide load range (5-1000 kg) with a full set of sizes, so a suitable model can be matched to equipment weight and site conditions, reducing vibration transmission and structural noise while protecting both equipment and building structure. Non-standard versions are available, built to project drawings — call us for selection advice.

Service hotline:0534-2555668

Key features · hanger spring vibration isolator

High damping · low natural frequency · easy installation · wide load range

H

High damping

A quality helical spring with damping structure gives high damping and good isolation, absorbing vibration from running equipment.

L

Low natural frequency

A low natural frequency gives clear vibration and noise isolation, with a marked effect on structure-borne noise.

E

Easy installation

Compact and easy to install, suited to suspended ceiling air conditioners, fans, fresh-air units and pipework.

W

Wide load range

Loads from 5 kg to 1000 kg with a full size range, matching different equipment weights and installation conditions.

Dimension drawing

DJZ series hanger spring isolator dimension drawing (unit photo with engineering dimensions)

DeLENG DJZ series hanger spring vibration isolator

Dimension table

DJZ series hanger spring isolator model dimension table (mm)

Model Load range (kg) Overall dimensions (mm) Screw
H Upper A Lower A
DJZ-0 0-10 80 40 40 M8*100
DJZ-1 5-20 80 60 60 M8*100
DJZ-2 15-30 100 50 50 M10*100
DJZ-3 30-50 100 50 50 M10*120
DJZ-4 50-80 120 60 60 M12*120
DJZ-5 80-120 120 60 60 M12*120
DJZ-6 120-160 140 80 80 M14*140
DJZ-7 160-200 140 80 80 M14*140

Product photos

Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator · photographed at our factory

DeLENG DJZ series hanger spring vibration isolator
DeLENG DJZ series hanger spring vibration isolator
DeLENG DJZ series hanger spring vibration isolator

Note: the dimensions above are for reference; the actual product and project selection take precedence.

Applications

Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator · suitable for many applications

C

Commercial projects

Applications of the Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator

H

HVAC systems

Applications of the Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator

P

Project-specific builds

Applications of the Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator

F

Factories / commercial spaces

Applications of the Dezhou DeLENG DJZ Series Hanger Spring Vibration Isolator

FAQ

Q: How do I choose the number of hanger points and the load rating?

A: First work out the total equipment weight (including ductwork, pipework and accessories), distribute it evenly across the hanger points with a 1.2 safety factor, then select the model from the XHS series dimension table on this page according to the load per point.

Q: How effective is the vibration isolation?

A: A quality helical spring with damping structure gives a low natural frequency and high damping, clearly isolating running vibration and structure-borne noise from suspended fans and AHU units, so floor resonance and noise drop markedly.

Q: What should I watch during installation?

A: Keep the hanger rods vertical and the load even between points; the spring must not be eccentrically or laterally loaded. Level the equipment after installation, then release the limit bolts gradually.

Q: Can it be customised to equipment parameters?

A: Yes. Spring stiffness and overall dimensions are tailored to equipment weight, number of hanger points, installation height and available space — just send us the equipment parameters.

Related products

Central AC Unit Filter (Custom / Standard / Folded)

Central AC Unit Filter (Custom / Standard / Folded)

Product showcase

View details →

Silicone Canvas Duct Connector (Multi-flange)

Silicone Canvas Duct Connector (Multi-flange)

Product showcase

View details →

TDF Flange Duct Flexible Connector (Multi-type, Custom)

TDF Flange Duct Flexible Connector (Multi-type, Custom)

Product showcase

View details →

AHU Drain Pan (Galvanised / Stainless, Custom)

AHU Drain Pan (Galvanised / Stainless, Custom)

Product showcase

View details →

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need XHS Series Hanger Spring Vibration Isolator?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668