Dezhou DeLENG ZJZ Damped Spring Vibration Isolator (for AC units, fans and pumps) — direct from our Dezhou factory: reliable quality and non-standard customisation, widely used in commercial projects, HVAC systems, project-specific builds and factory or commercial spaces.

The ZJZ damped spring isolator combines a spring with rubber in a composite isolation structure. Installed under fans, pumps, AHU units, cooling towers and compressors, it uses low-frequency spring isolation plus the high damping of rubber to absorb and attenuate running vibration, reducing transmission and structural noise while protecting the equipment and the building structure.
The DeLENG ZJZ isolator uses a national-standard cast iron housing with a thickened rubber base, powder-coated and baked for corrosion resistance, slip resistance, stability and long service. Models run from ZJZ-1 to ZJZ-16 with loads from 30 kg to 1050 kg — a full range for flexible matching — and non-standard versions can be built to project requirements; call us for selection advice.
Service hotline:0534-2555668
Factory direct · customisable · reliable quality
A spring-and-rubber composite structure absorbs and attenuates vibration from fans, pumps and AHU units with high isolation efficiency.
The ZJZ series covers loads from 30 kg to 1050 kg with multiple models, matching different equipment weights with stable performance.
Low-frequency spring isolation combined with high rubber damping markedly cuts vibration transmission for better isolation and quieter operation.
A ductile iron housing with powder coating and a thickened rubber base resists corrosion and slipping, giving long service and dependable safety.
National-standard cast iron housing · thickened rubber base · powder-coated finish
ZJZ damped spring isolator dimension drawing (section and top view, mm)

ZJZ series isolator model dimension table (mm)
| Model | Load range (kg) | Vertical stiffness (N/mm) | Overall dimensions (mm) | |||||
|---|---|---|---|---|---|---|---|---|
| H | L | D | Li | M | O | |||
| ZJZ-0 | 0-30 | 25 | 70 | 158 | 94 | 128 | M12 | 012 |
| ZJZ-1 | 30-45 | 25 | 77 | 173 | 111 | 139 | M12 | 012 |
| ZJZ-2 | 45-80 | 44 | 77 | 173 | 111 | 139 | M12 | 012 |
| ZJZ-3 | 80-120 | 67 | 82 | 173 | 111 | 139 | M12 | 012 |
| ZJZ-4 | 120-160 | 107 | 97 | 177 | 125 | 144 | M12 | 012 |
| ZJZ-5 | 160-200 | 133 | 97 | 177 | 125 | 144 | M12 | 012 |
| ZJZ-6 | 200-260 | 173 | 97 | 177 | 125 | 144 | M12 | 012 |
| ZJZ-7 | 260-320 | 213 | 97 | 177 | 125 | 144 | M12 | 012 |
| ZJZ-8 | 320-360 | 240 | 100 | 223 | 155 | 189 | M12 | 015 |
| ZJZ-9 | 360-420 | 280 | 115 | 223 | 155 | 189 | M12 | 015 |
| ZJZ-10 | 420-480 | 320 | 115 | 223 | 155 | 189 | M12 | 015 |
| ZJZ-11 | 480-550 | 366 | 115 | 223 | 155 | 189 | M12 | 015 |
| ZJZ-12 | 550-630 | 420 | 115 | 223 | 155 | 189 | M12 | 015 |
| ZJZ-13 | 630-700 | 467 | 118 | 270 | 190 | 235 | M14 | 016 |
| ZJZ-14 | 700-800 | 533 | 118 | 270 | 190 | 235 | M14 | 016 |
| ZJZ-15 | 800-900 | 600 | 118 | 270 | 190 | 235 | M14 | 016 |
| ZJZ-16 | 900-1050 | 700 | 133 | 270 | 190 | 235 | M14 | 016 |
| ZJZ-17 | 1050-1200 | 800 | 133 | 270 | 190 | 235 | M14 | 016 |
| ZJZ-18 | 1200-1650 | 1100 | 143 | 352 | 245 | 305 | M16 | 016 |
| ZJZ-19 | 1650-2200 | 1467 | 153 | 352 | 245 | 305 | M16 | 016 |
| ZJZ-20 | 2200-2750 | 1833 | 153 | 352 | 245 | 305 | M16 | 016 |
| ZJZ-21 | 2750-3300 | 2200 | 153 | 352 | 245 | 305 | M16 | 016 |
Note: model selection should follow equipment weight and project conditions — call us for advice.
Ductile iron housing · quality rubber · powder-coated finish · ribbed anti-slip design

DeLENG factory · product photos
Dezhou DeLENG ZJZ Damped Spring Vibration Isolator (for AC units, fans and pumps) · suitable for many applications
Applications of the Dezhou DeLENG ZJZ Damped Spring Vibration Isolator (for AC units, fans and pumps)
Applications of the Dezhou DeLENG ZJZ Damped Spring Vibration Isolator (for AC units, fans and pumps)
Applications of the Dezhou DeLENG ZJZ Damped Spring Vibration Isolator (for AC units, fans and pumps)
Applications of the Dezhou DeLENG ZJZ Damped Spring Vibration Isolator (for AC units, fans and pumps)
A: Take the total equipment weight (unit, pipework and accessories), apply a 1.2 safety factor, divide evenly between support points, then select the model from the load range in the dimension table on this page. The ZJZ series runs from ZJZ-0 to ZJZ-21, covering 30 kg to 3300 kg.
A: The spring-and-rubber composite isolates at low frequency with high damping, absorbing the running vibration of fans, pumps and AHU units, blocking its path to the floor slab and foundation and reducing structural noise.
A: Use the same model at every support point of one unit, load them evenly and leave none eccentric or unsupported. Seat the base flat on the foundation and tighten the anchor bolts only after the equipment is levelled.
A: Yes. Load, stiffness, connection type and dimensions can be built to project drawings — provide equipment weight, number of support points and installation method.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.