A built-in motorised actuator adjusts the blade angle remotely, giving automatic switching between the three seasons. Designed for tall spaces above 3.8 m — airports, stations, exhibition centres, stadiums and industrial plants. Full range from φ200 to φ630.

The DELENG DL-D motorised swirl diffuser is based on the adjustable swirl diffuser but with a built-in motorised actuator, so the blade angle no longer needs to be set by hand on site: it can be switched remotely from a building management system or a thermostat. It is designed for tall spaces with a floor-to-ceiling height above 3.8 m, and is widely used in airports, station waiting halls, exhibition centres, theatres, stadiums and industrial plants.
Adjustable blades and a diffuser ring sit on the face of the diffuser; the blades are designed on aerodynamic principles so that the air leaves as a vortex with a defined initial velocity, giving a long throw and wide coverage. The motorised actuator adjusts the blade angle remotely: in summer the cooling mode spreads cold air as a divergent swirl; in spring and autumn the fresh-air mode supplies fresh air over a large area; in winter the heating mode sends the warm jet vertically into the occupied zone.
The outer frame is spun from quality aluminium sheet, giving high strength and good appearance; the surface can be electrostatic powder coated to match the decor. It can be used with a volume control damper and a plenum box, in sizes from φ200 to φ630 in 8 steps.
Service hotline: 0534-2555668
A built-in motorised actuator controls the blade angle remotely, so no manual adjustment at height is needed.
Ceilings above 3.8 m: airports, stations, exhibition centres, stadiums, plants.
Adjustable blades plus diffuser ring discharge a swirling jet at initial velocity, with long throw and wide coverage.
Spun from quality aluminium sheet: high strength, good appearance, electrostatic powder coating available.
The actuator sets the blades to the cooling angle; cold air leaves as a divergent swirl and sinks evenly without draughts.
Motorised setting to the normal-temperature angle so fresh air is supplied over a large area, diluting the room air with a high airflow rate.
Motorised setting to the heating angle so the warm jet is concentrated vertically into the occupied zone instead of floating at the ceiling.
Unit mm · A outer diameter / B cut-out size / C duct connection
| Model | A outer dia (mm) | B cut-out (mm) | C duct (mm) | H1(mm) | H2(mm) |
|---|---|---|---|---|---|
| φ200 | 300 | 255 | 200 | 135 | 110 |
| φ250 | 360 | 315 | 250 | 145 | 110 |
| φ315 | 455 | 410 | 320 | 150 | 110 |
| φ350 | 500 | 449 | 350 | 155 | 110 |
| φ400 | 570 | 510 | 400 | 180 | 180 |
| φ450 | 640 | 570 | 450 | 215 | 145 |
| φ500 | 760 | 700 | 500 | 245 | 180 |
| φ630 | 865 | 800 | 630 | 295 | 200 |
Cooling throw measured at a 45° supply angle; heating throw at a 75° supply angle
| Model | Airflow (m³/h) | Pressure loss (Pa) | Noise dB(A) | Cooling throw (m) Δt=-8℃ |
Heating throw (m) Δt=+15℃ |
|---|---|---|---|---|---|
| φ200 | 300 | 10 | 23 | 1.7 | 1.4 |
| 500 | 28 | 35 | 3.0 | 2.6 | |
| 600 | 40 | 46 | 3.7 | 3.3 | |
| 800 | 82 | 51 | 5.0 | 4.5 | |
| 1000 | 99 | 56 | 6.0 | 5.3 | |
| φ250 | 300 | 10 | 23 | 1.7 | 1.4 |
| 500 | 28 | 35 | 3.0 | 2.6 | |
| 600 | 40 | 46 | 3.7 | 3.3 | |
| 800 | 82 | 51 | 5.0 | 4.5 | |
| 1000 | 99 | 56 | 6.0 | 5.3 | |
| φ315 | 500 | 23 | 25 | 1.8 | 1.5 |
| 800 | 60 | 36 | 3.1 | 2.7 | |
| 1100 | 100 | 45 | 3.5 | 3.1 | |
| 1300 | 142 | 52 | 4.7 | 4.2 | |
| 1600 | 205 | 57 | 6.0 | 5.3 | |
| φ350 | 500 | 23 | 25 | 1.8 | 1.5 |
| 800 | 60 | 36 | 3.1 | 2.7 | |
| 1100 | 100 | 45 | 3.5 | 3.1 | |
| 1300 | 142 | 52 | 4.7 | 4.2 | |
| 1600 | 205 | 57 | 6.0 | 5.3 | |
| φ400 | 800 | 11 | 27 | 2.7 | 2.2 |
| 1200 | 25 | 38 | 3.8 | 3.2 | |
| 1600 | 43 | 47 | 5.2 | 4.3 | |
| 2000 | 68 | 53 | 6.5 | 5.3 | |
| 2400 | 102 | 58 | 7.7 | 6.5 | |
| φ500 | 1200 | 12 | 28 | 2.1 | 1.7 |
| 1600 | 23 | 39 | 3.2 | 2.8 | |
| 2000 | 29 | 45 | 3.6 | 3.2 | |
| 3000 | 82 | 52 | 5.3 | 4.6 | |
| 3500 | 96 | 58 | 6.2 | 5.5 | |
| φ630 | 1900 | 19 | 30 | 3.4 | 3.0 |
| 2600 | 33 | 40 | 4.2 | 3.8 | |
| 3300 | 50 | 46 | 5.7 | 5.3 | |
| 4000 | 86 | 55 | 6.9 | 6.4 | |
| 4800 | 128 | 59 | 8.4 | 7.7 |
Can be installed together with a volume control damper or a plenum box, with suspended fixing; the motorised actuator provides a 24 V / 220 V control cable for connection to the building management system.
A: The dimensions, airflow, pressure loss, noise and other performance data are exactly the same. The difference is the blade adjustment: the manual version has to be set by hand at height, while the motorised version has a built-in actuator that switches automatically between summer, spring/autumn and winter modes from a thermostat or building management system — ideal for high spaces where access for maintenance is difficult.
A: The actuator accepts 24 V or 220 V supply with on/off or analogue control. It can be connected to a BA building management system or controlled on site with a separate thermostat. Please state the supply voltage and control signal type when ordering.
A: Select the model from the space volume and the required airflow, using the airflow – pressure loss – throw data in the table above. Send us the project drawings and DELENG technical staff will help with selection, tel. +86 534 2555668.
DELENG factory photo · DL-D motorised swirl diffuser
Remote motorised supply
Centralised control for large areas
Smart temperature control for venues
Ventilation for tall workshops
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.