The DeLENG DTK series external rotor air conditioning fan uses an external-rotor motor with a direct-drive double-inlet design and a forward-curved multi-blade impeller for high efficiency and low noise. Compact build saves installation space; suitable for central air conditioning, purifying equipment and pressure supply systems.

The DeLENG DTK series external rotor air conditioning fan is a high-efficiency, low-noise centrifugal fan for supply and exhaust. It uses an external-rotor motor with a direct-drive double-inlet design and is widely used in central air conditioning systems, purifying equipment packages and general pressure supply duties.
The unit has a compact build and is easy to install: it saves space while delivering outstanding running efficiency and quiet operation. The forward-curved multi-blade impeller keeps the airflow smooth and the efficiency high, making it an ideal choice for modern ventilation systems.
Service hotline: +86 534 2555668
High efficiency · low-noise running · easy installation · wide application
Forward-curved multi-blade impeller: high efficiency, low energy consumption and low long-term running cost.
Optimised impeller structure plus direct-drive motor keeps running noise very low for a quiet environment.
Compact structure, quick and simple installation, saves installation space and suits many environments.
Central air conditioning systems, purifying equipment packages and general pressure supply duties.
Quality details you can see — built for your satisfaction
XDW 200S∼450L · 27 sizes · 380V three-phase · external rotor direct-drive double-inlet · full factory performance data
| Frame size (No.) | Airflow (m³/h) | Airflow range (m³/h) | Total pressure (Pa) | Noise dB(A) | Power (kW) | Current (A) | Voltage (V) |
|---|---|---|---|---|---|---|---|
| XDW 200S-4 | 1400 | 600-1500 | 300 | 61 | 0.18 | 0.53 | 380V |
| XDW 200L-4 | 2000 | 1300-2100 | 300 | 63 | 2.5 | 0.7 | 380V |
| XDW 250AS-4 | 2100 | 1800-2300 | 380 | 64 | 0.25 | 0.7 | 380V |
| XDW 250AM-4 | 3000 | 2400-3300 | 390 | 64 | 0.37 | 1.23 | 380V |
| XDW 250AL-4 | 4000 | 3300-4100 | 480 | 64 | 0.55 | 1.46 | 380V |
| XDW 250S-4 | 2200 | 1900-2400 | 380 | 64 | 0.32 | 1.1 | 380V |
| XDW 250S-4 | 2400 | 1900-2500 | 390 | 65 | 0.37 | 1.23 | 380V |
| XDW 250M-4 | 3000 | 2500-3100 | 390 | 66 | 0.45 | 1.39 | 380V |
| XDW 250M-4 | 3200 | 2500-3300 | 420 | 67 | 0.55 | 1.46 | 380V |
| XDW 250L-4 | 4100 | 3300-4300 | 480 | 67 | 0.75 | 1.75 | 380V |
| XDW 250L-4 | 4300 | 3300-4400 | 500 | 68 | 1.1 | 2.4 | 380V |
| XDW 280S-4 | 4300 | 3300-4600 | 520 | 68 | 1.1 | 2.5 | 380V |
| XDW 280M-4 | 5000 | 4000-5200 | 500 | 67 | 1.1 | 2.5 | 380V |
| XDW 280M-4 | 5800 | 4500-6000 | 500 | 69 | 1.1 | 2.6 | 380V |
| XDW 280L-4 | 6300 | 5000-6500 | 520 | 71 | 1.5 | 3.2 | 380V |
| XDW 315S-4 | 5400 | 4500-6000 | 600 | 75 | 1.8 | 3.6 | 380V |
| XDW 315M-4 | 7100 | 5500-7900 | 580 | 76 | 1.8 | 3.7 | 380V |
| XDW 315L-4 | 8500 | 7000-8800 | 600 | 76 | 2.2 | 4.4 | 380V |
| XDW 355S-4 | 7500 | 5500-8000 | 800 | 77 | 3.0 | 6.0 | 380V |
| XDW 355M-4 | 11000 | 8000-12000 | 800 | 79 | 3.0 | 6.1 | 380V |
| XDW 355L-4 | 13500 | 9500-14800 | 800 | 80 | 4.0 | 8.1 | 380V |
| XDW 400S-6 | 6000 | 4500-6500 | 600 | 70 | 1.5 | 4.1 | 380V |
| XDW 400M-6 | 7000 | 5400-7600 | 600 | 71 | 1.5 | 4.9 | 380V |
| XDW 400L-6 | 8800 | 6500-9000 | 600 | 75 | 2.2 | 5.8 | 380V |
| XDW 450S-6 | 11000 | 8000-12500 | 800 | 79 | 3.0 | 7.6 | 380V |
| XDW 450M-6 | 16000 | 14000-18000 | 800 | 81 | 5.5 | 12.5 | 380V |
| XDW 450L-6 | 21000 | 17000-23000 | 800 | 82 | 7.5 | 17 | 380V |
Note: the figures above are standard-condition factory data. For selection, contact a DeLENG engineer on +86 534 2555668.
XDW 200S∼450L · 23 frame sizes · double-inlet centrifugal structure · outline and installation dimensions
| Frame size | A | B | C | D | E | F | G | H | I |
|---|---|---|---|---|---|---|---|---|---|
| XDW 200L | 311 | 360 | 200 | 240 | 320 | 270 | 340 | 120 | 170 |
| XDW 250AS | 373 | 390 | 230 | 270 | 270 | 220 | 280 | 125 | 175 |
| XDW 250AM | 373 | 390 | 230 | 270 | 350 | 300 | 360 | 125 | 175 |
| XDW 250AL | 373 | 390 | 230 | 270 | 430 | 380 | 440 | 125 | 175 |
| XDW 250S | 373 | 426 | 230 | 270 | 270 | 220 | 280 | 150 | 200 |
| XDW 250M | 373 | 426 | 230 | 270 | 350 | 300 | 360 | 150 | 200 |
| XDW 250L | 373 | 426 | 230 | 270 | 430 | 380 | 440 | 150 | 200 |
| XDW 280S | 437 | 481 | 280 | 321 | 320 | 270 | 340 | 200 | 250 |
| XDW 280M | 437 | 481 | 280 | 321 | 400 | 350 | 420 | 200 | 250 |
| XDW 280L | 437 | 481 | 280 | 321 | 480 | 430 | 500 | 200 | 250 |
| XDW 315S | 519 | 542 | 280 | 321 | 320 | 270 | 340 | 240 | 290 |
| XDW 315M | 519 | 542 | 280 | 321 | 400 | 350 | 420 | 240 | 290 |
| XDW 315L | 519 | 542 | 280 | 321 | 480 | 430 | 500 | 240 | 290 |
| XDW 355S | 600 | 640 | 350 | 550 | 400 | 350 | 420 | 320 | 370 |
| XDW 355M | 600 | 640 | 350 | 550 | 490 | 440 | 520 | 320 | 370 |
| XDW 355L | 600 | 640 | 350 | 550 | 560 | 510 | 590 | 320 | 370 |
| XDW 400S | 669 | 725 | 400 | 620 | 400 | 350 | 430 | 320 | 370 |
| XDW 400M | 669 | 725 | 400 | 620 | 490 | 440 | 520 | 320 | 370 |
| XDW 400L | 669 | 725 | 400 | 620 | 560 | 510 | 590 | 320 | 370 |
| XDW 450S | 732 | 775 | 450 | 685 | 515 | 455 | 535 | 360 | 410 |
| XDW 450M | 732 | 775 | 450 | 685 | 595 | 545 | 625 | 360 | 410 |
| XDW 450L | 732 | 775 | 450 | 685 | 685 | 635 | 715 | 360 | 410 |
Custom sizes available — contact us for your project
Matching fans for central air conditioning systems
Supply and exhaust for purifying equipment packages
General pressure supply duty
Ventilation for many building types
A: It uses an external-rotor motor with direct drive and an optimised impeller, so running noise is low; a silencer can be added to reduce it further, which suits noise-sensitive installations.
A: Yes. Units are selected and built to the system airflow, resistance and installation space, and non-standard builds are supported. Send us the project data and DeLENG will help with the selection.
A: The external-rotor direct-drive double-inlet design is smaller, more efficient and quieter: there is no belt drive and no transmission loss, so maintenance is simpler.
A: Central air conditioning units, purifying equipment, clean-air supply, pressure supply systems and general ventilation and air exchange — an ideal fan for ventilation packages.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.