Home›Products ›FCU Accessories ›ABS Scroll and Fan Wheel for Fan Coil Units

ABS Scroll and Fan Wheel for Fan Coil Units

DEZHOU DELENG HVAC · Factory direct supply  

ABS Scroll and Impeller for Fan Coil Units

Fan coil scroll and impeller with multi-size selection (impeller length 163/180/190 mm etc.), thickened ABS or galvanised steel housing, 12/14 mm shaft options, quiet design with no rubbing and low noise.

Thickened ABS / galvanised steelImpeller length 163/180/190 mm12 / 14 mm shaftQuiet, no rubbingMulti-size selection  
ABS Scroll and Impeller for Fan Coil Units — DeLENG, central AC terminal equipment

Product overview

The DeLENG ABS / galvanised steel scroll and impeller is a core component of the fan coil air path, offered in multiple sizes (impeller length 163/180/190 mm etc.) to suit different fan coil installations.

Two housing materials are available: thickened ABS, corrosion and wear resistant and suited to damp, dusty HVAC environments, and galvanised steel for greater structural stability. The impeller is a quiet type: balanced blade angles give rubbing-free running with low noise and high efficiency. Shaft diameter is available in 12 or 14 mm, and the outlet size matches the corresponding fan coil opening for easy installation.

Service hotline: 0534-2555668

Key features · ABS scroll and impeller

Two materials · Multi-size matching · Dynamic balancing · Quiet and efficient

A

ABS injection moulding

Thickened ABS moulded in one piece: light, non-rusting and corrosion resistant, made for long service in damp environments.

T

Two housing materials

ABS plastic or galvanised steel sheet, selected to suit economy or durability needs.

M

Multi-size matching

Impeller lengths 163/180/190 mm with 12 or 14 mm shafts, matching the various fan coil models.

B

Balanced and quiet

Each unit is dynamically balanced: smooth running with no rubbing noise, low sound level and high airflow efficiency.

Selling points

ABS scroll and impeller · three core selling points

Quiet impeller with balanced blade angles and no rubbing — DeLENG
ABS scroll and impeller: thickened ABS, quiet running, easy installation — DeLENG
Thickened ABS: corrosion and wear resistant — DeLENG

Product dimensions

Impeller length / diameter / shaft dia. / outlet size · multiple sizes

Scroll and impeller dimensions, impeller length 190 mm — DeLENG
Scroll and impeller dimensions, impeller length 180 mm — DeLENG
Scroll and impeller dimensions, impeller length 163 mm — DeLENG

ABS scroll and impeller specifications

Dedicated fan coil ventilation accessory

Parameter Value
Model FP-ABSYL
Housing material Thickened ABS / galvanised steel (optional)
Impeller length 163 / 180 / 190 mm etc.
Shaft diameter 12 / 14 mm shaft (optional)
Features Quiet type, rubbing-free running
Selection note: The above are available size ranges; select according to the fan coil model and opening size. Call 0534-2555668 for advice.

Product photos

Real photos · thickened ABS / galvanised steel

Scroll and impeller product photo — DeLENG
Scroll and impeller product photo — DeLENG
Scroll and impeller product photo — DeLENG

Applications · fan coil ventilation

H

HVAC engineering

Impeller replacement for HVAC fan coil units

C

Commercial AC systems

Air path component for commercial air-conditioning systems

S

Service replacement

Repair and replacement of fan coil impellers

E

Equipment matching

Matching component for fan coil equipment

FAQ

Q: Which housing materials are available?

A: Thickened ABS or galvanised steel. ABS is corrosion and wear resistant and suits damp, dusty HVAC environments; galvanised steel is structurally stable and handles load better. Select by the working environment.

Q: What sizes are available and how is the shaft chosen?

A: Impeller lengths cover 163/180/190 mm and more, with 12 or 14 mm shafts. The outlet size matches the corresponding fan coil opening, so select by the fan coil model and opening.

Q: Why is this impeller quieter?

A: Balanced blade angles and individual dynamic balancing give rubbing-free running with low noise and high efficiency, suited to noise-sensitive places such as offices and hospital wards.

Q: How do I know the impeller needs replacing, and what matters when fitting it?

A: Falling airflow, rising noise or a wobbling, rubbing sound usually means dust imbalance or a worn shaft bore: replace with the same size. When fitting, align the shaft and outlet size and keep the gap between impeller face and housing even.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need ABS Scroll and Fan Wheel for Fan Coil Units?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top