DeLENG FP-WA concealed horizontal fan coil units, factory direct: pure copper motor, copper-tube coil, ultra-slim chassis for concealed ceiling installation, models FP-34 to FP-238, low noise and energy saving.

The DeLENG concealed horizontal fan coil unit consists of a high-performance centrifugal fan and a precision coil heat exchanger. As terminal equipment of central air-conditioning systems it is widely used in hotels, restaurants, factories, hospitals, exhibition halls, shopping centres and office buildings, delivering cooling, dehumidification and heating to create a comfortable indoor environment. Its low-profile contour fits seamlessly into the ceiling and blends with the interior finish; the customised supply outlet is neat in appearance and improves the use of space.
The DeLENG FP-WA series uses an ultra-thin design with a chassis height of only 230 mm, concealed inside the ceiling without taking up room space. Core configuration: pure copper fan motor, seamless copper-tube coil (hydrophilic aluminium fins) and an optimised galvanised-steel scroll housing blower wheel with dynamic balance correction, giving three advantages: low noise, high efficiency and easy maintenance. The range covers all models from FP-34 to FP-238.
Service hotline: +86 534 2555668
Ultra-thin concealed installation · Pure copper motor · Copper-tube coil · Low-noise operation
Chassis height only 230 mm; concealed inside the ceiling, no room space taken, and blends with the interior finish.
Pure copper fan motor for stable running, fitted with a dynamically balanced blower wheel: low noise, energy saving.
Seamless copper-tube coil with hydrophilic aluminium fins: high heat-exchange efficiency, durable and leak-free.
Pure copper motor plus an optimised balanced blower wheel: minimum noise down to 35 dB(A) for a quiet room.
| Performance | Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| Rated air volume m³/h |
High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
| Medium | 260 | 390 | 510 | 640 | 770 | 1020 | 1280 | 1530 | 1790 | |
| Low | 170 | 260 | 340 | 430 | 510 | 680 | 850 | 1020 | 1190 | |
| Rated cooling capacity | High | 1.98 | 2.8 | 3.87 | 4.58 | 5.42 | 7.38 | 9.08 | 11.1 | 12.9 |
| Rated heating capacity | High | 3.39 | 4.5 | 6.35 | 7.45 | 9.22 | 12.4 | 16.3 | 19.5 | 20.2 |
| Input power | 12Pa | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 |
| 30Pa | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | |
| 50Pa | 49 | 66 | 84 | 100 | 118 | 174 | 210 | 250 | 300 | |
| Noise | 12Pa | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 |
| 30Pa | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | |
| 50Pa | 42 | 44 | 46 | 47 | 49 | 50 | 52 | 54 | 56 | |
| Water flow | — | 350 | 510 | 660 | 800 | 980 | 1280 | 1600 | 1920 | 2230 |
| Water resistance | — | 30 | 30 | 30 | 30 | 40 | 40 | 40 | 40 | 50 |
| Weight | WA | 17 | 18 | 19 | 22 | 26 | 39 | 43 | 49 | 52 |
| With return box | 20 | 22 | 23 | 27 | 30 | 44 | 48 | 54 | 58 | |
| Water connection | ||||||||||
| Condensate connection | ||||||||||
| Power supply | ||||||||||

| Size | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A (unit length) | 750 | 850 | 950 | 1050 | 1150 | 1350 | 1650 | 1850 | 2050 |
| B (supply outlet length) | 460 | 580 | 650 | 780 | 900 | 1100 | 1350 | 1550 | 1750 |
| C (hanger hole spacing) | 490 | 610 | 680 | 810 | 930 | 1130 | 1380 | 1580 | 1780 |

| Size | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A (unit length) | 750 | 850 | 950 | 1050 | 1150 | 1350 | 1650 | 1850 | 2050 |
| B (supply outlet length) | 460 | 580 | 650 | 780 | 900 | 1100 | 1350 | 1550 | 1750 |
| C (hanger hole spacing) | 490 | 610 | 680 | 810 | 930 | 1130 | 1380 | 1580 | 1780 |
Concealed in the ceiling; quiet and comfortable for guests
Cooling, dehumidification and heating in a pleasant environment
Terminal equipment for office-building central air conditioning
Cooling and heating for commercial spaces
A: DeLENG gives a 3-year warranty on the complete unit, 5 years on the motor and 5 years leak-free on the coil. We are a source factory in Dezhou, Shandong, and customisation is supported.
A: Leaks are usually caused by a blocked condensate drain or damaged insulation. Check that the drain pan drains freely and that the insulation fully covers the pipes and joints; during installation keep the drain pan sloping towards the outlet.
A: DeLENG uses pure copper motors with dynamically balanced blower wheels, and the minimum noise is only 35 dB(A). If noise is higher than expected, check the blower wheel for dust, the anti-vibration hangers for looseness, and whether the fan speed is set too high.
A: The concealed horizontal unit is hidden in the ceiling: neat in appearance but needs ceiling space. The floor-standing exposed unit stands directly on the floor and needs no ceiling, which suits renovation projects. Heat-exchange performance is the same; only the installation method and appearance differ.
Selection and quotation: +86 534 2555668 | WeChat 0534-2555668 | sales@deleng.com




Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.