70℃ / 280℃ fire dampers in galvanised steel or stainless steel, square or circular, manual or motorised, fire-certified.

70°C / 280°C fire dampers in galvanised or stainless steel, square or circular custom sizes, manual or motorised operation, fire-certified.

The DeLENG manual and motorised fire damper is made from quality galvanised steel, with a one-piece formed and welded body. It stays open in normal service and closes automatically when the smoke temperature in the duct reaches 70°C or 280°C, meeting smoke-leakage and fire-integrity requirements for the rated period and blocking smoke and fire.
It is used in the ventilation and smoke exhaust ducts of high-rise buildings, underground car parks, construction sites and metro systems. Manual or motorised control, square or circular custom sizes, galvanised or stainless steel.
70 / 280°C fusible · Manual or motorised · One-piece body · Custom sizes
Fire dampers close at 70°C and smoke fire dampers at 280°C, meeting smoke-leakage and fire-integrity requirements.
Can be opened and closed by hand, or fitted with an electric actuator for different control requirements.
One-piece formed and welded galvanised body: strong sealing and corrosion resistance.
Square or circular sizes can be customised, in galvanised or stainless steel, with a full size range.
| Product name | Fire damper series |
| Material | Galvanised steel, customised on request |
| Advantages | One-piece body, strong sealing, corrosion resistant |
| Application | Fire protection and smoke exhaust |
| Suitable for | High-rise buildings, underground car parks, construction sites, metro |
| Series | Name | Model | Function |
|---|---|---|---|
| Fire damper series (normally open) |
Fire damper | FHF-WSDc | Normally open; closes when the smoke temperature in the duct reaches 70°C in a fire, meeting smoke-leakage and fire-integrity requirements for the rated period. |
| Smoke fire damper | PFHF-WSDc | Normally open; closes when the smoke temperature reaches 280°C in a fire, meeting smoke-leakage and fire-integrity requirements for the rated period. | |
| Smoke exhaust damper series (normally closed) |
Fire damper | PYF-SDc | Normally open and meeting air-leakage limits; opened manually or by motor for smoke extraction in a fire. |
| Multi-blade smoke exhaust damper | PYF-SDc | Normally open and meeting air-leakage limits; opened manually or by motor for smoke extraction in a fire. |
Model code: W temperature control, K signal feedback, F volume control, D motorised, Y remote action, Z auto reset, S manual control.



High-rise buildings, car parks, sites, metro
Ventilation and smoke exhaust ducts
Smoke and fire protection
Temporary ventilation
Smoke exhaust systems
A: A standard fire damper closes at 70°C; a smoke fire damper at 280°C.
A: Yes. Square or circular sizes can be customised, in galvanised or stainless steel, with manual or motorised operation.
A: The product meets fire code requirements and is available with 3C certification; invoices can be issued.

Product display
View details →

Product display
View details →

Product display
View details →

Product display
View details →
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.