DeLENG Vertical Upward-discharge AHU (2,000-20,000 m³/h, Commercial)

Vertical air handling units are floor-standing cabinets for larger air volumes, with configurable coil, fan, filter and mixing sections.

Airflow 3,000-40,000 m³/hUpward discharge, duct-readyAluminium alloy frameCopper-tube coilMulti-stage filtration
DeLENG Vertical Upward-discharge AHU (2,000-20,000 m³/h, Commercial)

DeLENG Vertical Upward-discharge AHU (2,000-20,000 m³/h, Commercial)

Product introduction

The DeLENG KTL series vertical upward-discharge air handling unit is a floor-standing air treatment unit made up of a mixing section, a filter section, a cooling coil section and a fan section. The unit exchanges heat between chilled/hot water and the indoor return air to provide cooling, heating, dehumidification and filtration; the treated air leaves through the square outlet on top, connects directly to the ductwork and is distributed to each conditioned zone.

The casing uses an aluminium alloy profile frame with double-skin insulated panels and plug-in joints for a firm structure. The coil is a Φ16 copper tube with corrugated aluminium fins, available in 4-row, 6-row and 8-row versions, giving high heat-transfer efficiency and corrosion resistance. A primary filter (multi-layer aluminium mesh, nylon mesh or non-woven fabric) is fitted for effective air cleaning. The fan is a high-efficiency double-inlet centrifugal fan that runs smoothly and quietly.

Airflow covers 3,000–40,000 m³/h with cooling capacity 24.5–635.4 kW, suitable for large and medium air-conditioning applications such as industrial workshops, commercial buildings, shopping malls, hotels, hospitals and gymnasiums. No ceiling void is required, floor installation is straightforward, and variable-frequency or pole-changing speed control is supported.

Service hotline: 0534-2555668

Key features · Vertical Upward-discharge Air Handling Unit

Upward discharge

Square top outlet connects straight to ductwork

Floor installation

No ceiling void needed, saves space

Multi-function

Cooling, heating and dehumidification in one unit

Wide application

Suits both industrial and commercial projects

Selling points

Vertical AHU high efficiency
Vertical AHU copper-tube cooling coil
Vertical AHU aluminium alloy frame
Vertical AHU air purification filter

Technical parameters

Model Rated air volume (m³/h) External static pressure (Pa) Motor (kW) Rows Cooling capacity (kW) Chilled water (m³/h) Water resistance (kPa) Air resistance (Pa) Heating capacity (kW) Hot water (m³/h) Inlet/outlet pipe (in) Condensate pipe (in) Weight (kg) Noise dB(A)
KTL-03 3000 80 0.55 4 24.5 4.21 4.2 123 32.5 2.8 1.5 1 235 55
150 0.75 6 33.6 5.78 5.8 180 44.1 3.8 61
300 0.75 8 43.6 7.5 7.5 221 57.9 4.98 68
KTL-04 4000 80 0.75 4 32.4 5.57 9.2 121 42.8 3.68 1.5 1 280 57
150 0.75 6 43.7 7.51 13.4 171 58.7 5.05 64
300 1.1 8 57.6 9.9 18.2 217 76.3 6.6 72
KTL-05 5000 100 0.8 4 40.8 7.02 9.8 126 53.6 4.61 1.5 1 320 59
200 1.1 6 55.7 9.58 13.9 175 73.4 6.31 66
350 1.8 8 72.7 12.5 19.9 223 95.4 8.2 74
KTL-06 6000 150 1.1 4 49 8.43 10.5 118 63.5 5.46 2 1 350 62
300 1.5 6 66.9 11.5 26.3 180 87.9 7.56 68
400 1.8 8 87.2 15 23.3 221 113.3 9.74 75
KTL-07 7000 150 1.5 4 57.2 9.84 10.9 116 74.5 6.41 2 1 400 63
300 2.2 6 78.4 13.5 18.1 171 117.3 10.1 70
400 3 8 102 17.5 25.9 210 152.3 13.1 76
KTL-08 8000 150 2*0.8 4 65.4 11.2 12.9 130 85.6 7.4 2 1 440 64
300 2*1.5 6 90.9 15.6 20.4 191 117.3 10.1 66
400 3 8 116.3 20.0 29.1 235 152.3 13.1 73
KTL-09 9000 150 2*1.1 4 77.1 13.3 15 127 95.4 8.2 2 1 480 65
350 2*1.5 6 103.8 17.8 21.2 183 131.4 11.3 67
450 4 8 137.1 23.6 30.3 230 169.8 14.6 75
KTL-10 10000 150 2*1.1 4 88.2 15.2 15.4 133 107.2 9.2 2 1 525 65
350 2*1.8 6 112.2 19.3 21.7 175 146.7 12.6 71
450 4 8 156.9 27.0 30.8 235 190.7 16.4 78
KTL-15 15000 150 2*1.5 4 134.2 23.1 17.2 135 160.7 13.8 2 1 585 71
350 2*2.2 6 170.9 29.4 25.5 185 220.1 18.9 73
450 7.5 8 238.7 41.0 34.8 230 286 24.6 77
KTL-20 20000 200 2*3 4 180.4 31.0 19.3 135 211.7 18.2 2 1 820 71
400 2*4 6 244.2 42.0 23.8 191 293.1 25.2 76
450 11 8 320.9 55.2 29.9 240 376.7 32.4 78
KTL-25 25000 250 2*3 4 226.8 39.0 23 130 264.7 22.8 2 1 910 78
450 2*4 6 304.7 52.4 26.2 186 366.3 31.5 80
550 15 8 403.5 69.4 32.6 235 470.9 40.5 83
KTL-30 30000 250 2*4 4 262.9 45.2 23.2 133 318.3 27.4 2 1 1020 79
450 2*5.5 6 366.3 63.0 28.6 181 438.3 37.7 81
550 18.5 8 476.7 82.0 34.4 235 566.3 48.7 83
KTL-40 40000 300 2*5.5 4 357.1 61.4 26.5 140 423.5 36.4 2.5 1 1260 78
400 2*7.5 6 487.3 83.8 31.2 185 584 50.2 80
600 18.5 8 635.4 109.3 38.4 237 753.5 64.8 84

Dimensions (unit: mm)

Dimension drawing

Model L(mm) W(mm) H(mm) a(mm) b(mm) F(mm) G(mm) M(mm) N(mm) D(in)
KTL3 650 780 1530 320 320 610 760 680 1.5
KTL4 750 910 1530 320 400 610 760 810 1.5
KTL5 750 1050 1630 400 400 610 760 950 1.5
KTL6 750 1210 1630 400 500 610 760 1110 1.5
KTL7 850 1350 1630 400 630 610 760 1250 2
KTL8 850 1430 1750 320 400 675 280 840 1330 2
KTL9 850 1580 1750 400 400 675 280 840 1480 2
KTL10 850 1730 1750 400 500 675 320 840 1630 2
KTL12 1000 1950 1750 400 500 675 320 840 1850 2
KTL15 1000 1950 2080 400 630 870 320 1060 1850 2
KTL20 1150 2090 2260 500 630 1000 350 1220 1990 2
KTL25 1150 2450 2260 630 630 1000 400 1220 2350 2.5
KTL30 1150 2570 2480 630 800 1130 450 1370 2470 2.5
KTL40 1160 3180 2650 630 1000 1180 450 1440 3080 3

Note: E dimension – 4-row 83 mm, 6-row 138 mm, 8-row 193 mm.

Applications

I

Industrial workshop

Air supply for workshops and warehouses

C

Commercial building

Air conditioning for malls and offices

H

Hospital clean area

Purified air and fresh-air systems

S

Sports arena

Long-distance air supply for tall spaces

FAQ

Q: Can the top outlet be connected directly to ductwork?

A: Yes. The square top outlet is designed for duct connection, and the treated air goes straight from the outlet into the supply duct. Connect with flanges to the outlet size; for long ducts with high resistance, check the available external static pressure first.

Q: How are the airflow and cooling capacity selected?

A: The KTL series covers 3,000–40,000 m³/h with 24.5–635.4 kW cooling capacity, sized from the room cooling load and the supply-air temperature difference. Coils are available in 4, 6 and 8 rows — more rows give more heat transfer, and the row count is fixed together with the selection.

Q: How are the filter and coil maintained?

A: The primary filter (aluminium mesh, nylon mesh or non-woven fabric) can be taken out for cleaning or replacement. Clean dust off the coil fins regularly, fit a strainer at the water inlet, and drain the coil in winter to prevent freezing.

Q: Can the unit be customised?

A: Yes. Airflow, external static pressure, coil rows, filter section, variable-frequency or pole-changing control, and left/right water connections can all be adjusted to the project. Send the drawing or parameters and we will quote.

Selection and quotation: +86 534 2555668  |  WeChat: +86 534 2555668  |  Email: sales@deleng.com

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need Vertical Upward-discharge AHU?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.