Home›Products ›Exposed Horizontal FCU ›European Style Exposed Horizontal Fan Coil Unit

European Style Exposed Horizontal Fan Coil Unit

DELENG HVAC · Direct from our Dezhou factory  

European Style Exposed Horizontal Fan Coil Unit

DeLENG European style exposed horizontal fan coil unit: rounded cabinet design, simple installation with no ceiling work, electrostatically powder-coated casing, low-noise energy-saving operation — ideal for old-building retrofits and already-decorated spaces.

Rounded cabinetNo ceiling neededPowder-coated casingCopper-core quiet motorRetrofit ready  
European style exposed horizontal fan coil unit - DeLENG HVAC

Product introduction

The DeLENG European style exposed horizontal fan coil unit combines aesthetic design with practical function. Its distinctive rounded outline blends smoothly with modern interior styles. It can be hung anywhere beneath the ceiling and takes up no floor area, making it especially suitable for rooms with limited space.

The casing is electrostatically powder-coated: colour-fast, corrosion-resistant and easy to clean. No complicated ceiling work is needed — hang it, connect the pipes and it is ready to run, so the installation period is short. A copper-core motor runs quietly and the hydrophilic coil delivers high heat exchange, making it an ideal choice for air-conditioning retrofit of old buildings.

Service hotline:0534-2555668

Key features · Why choose the European style exposed unit

Rounded design · Flexible hanging · Powder-coated casing · Copper-core quiet motor

R

Rounded cabinet design

The distinctive rounded outline blends smoothly with modern interior decoration.

F

Flexible hanging, space-saving

It can be hung anywhere under the ceiling, uses no floor area and needs no ceiling work.

P

Powder-coated casing

Electrostatic powder coating keeps the colour, resists corrosion and cleans easily, extending service life.

C

Copper-core quiet motor

A copper-core quiet motor with a hydrophilic coil gives high heat exchange and low-noise operation.

Exposed horizontal fan coil unit performance data

High-purity copper tubes with W-shaped aluminium fins, mechanically expanded · working pressure 1.6 MPa

Performance Model FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Airflow
m³/h
High 340 510 680 850 1020 1360 1700 2040 2380
Medium 255 383 510 638 765 1020 1275 1530 1785
Low 170 255 340 425 510 680 850 1020 1190
Cooling capacity W High 1800 2700 3600 4500 5400 7200 9000 10800 12600
Medium 1440 2160 2880 3600 4320 5760 7200 8640 10080
Low 1170 1755 2340 2925 3510 4680 5850 7020 8190
Heating capacity W High 2700 4050 5400 6750 8100 10800 13500 16200 18900
Medium 2160 3240 4320 5400 6480 8640 10800 12960 15120
Low 1755 2633 3510 4388 5265 7020 8775 10530 12285
Input power W 12Pa 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 12Pa 37 39 41 43 45 46 48 50 52
30Pa 40 42 44 46 47 48 50 52 54
50Pa 42 44 46 47 49 50 52 54 56
Water flow m³/h — 0.39 0.55 0.70 0.82 0.91 1.34 1.59 1.80 2.07
Water resistance kPa — 12 16 20 23 26 28 32 38 42
Weight kg (FP-WM) — 23 27 29 30 33 46 52 55 64
Water pipe connection DN20 female thread
Condensate pipe DN20 male thread
Power supply Single phase 220V / 50Hz

Exposed horizontal fan coil unit overall dimensions

Exposed horizontal fan coil unit overall dimensions - A unit length, B hanger hole spacing, C unit height, water outlet / inlet / condensate
Model FP-34WM FP-51WM FP-68WM FP-85WM FP-102WM FP-136WM FP-170WM FP-204WM FP-238WM
A Unit length (mm) 790 940 980 1100 1250 1450 1680 1880 2080
B Hanger hole spacing (mm) 490 610 680 810 930 1130 1380 1580 1780
C Unit height (mm) 470 620 660 780 930 1130 1360 1560 1760

Note: four 4-Φ10 hanger holes; unit height 235 mm, depth 550 mm. Water outlet, water inlet and condensate pipes are on the side of the unit.

Applications · Retrofit of decorated spaces

O

Old-building retrofit

Fewer pipe runs, lower retrofit cost

D

Decorated homes

Hang and connect directly without disturbing the decoration

O

Office spaces

Low-noise operation, suitable for offices

H

Hotel rooms

Neat appearance that matches the interior

FAQ

Q: What is the difference between exposed and concealed horizontal units?

A: The difference is the casing. The exposed unit has a finished cabinet that stays visible, while the concealed unit has no casing and is hidden in the ceiling. The heat-exchange core is identical; the exposed version adds a cabinet and mounting brackets, so it costs slightly more.

Q: Is the exposed horizontal unit noisy?

A: The DeLENG exposed horizontal unit uses a copper-core quiet motor: 38 dB(A) at low speed and 48 dB(A) at high speed, which is fully adequate for offices and hotels.

Q: Does it need a ceiling?

A: No complicated ceiling work is required. It is suspended horizontally below the wall or ceiling, pipes are connected and it is ready to use, so the installation period is short.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need a european Style Exposed Horizontal Fan Coil Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top