Home›Products ›Exposed Vertical FCU ›DeLENG Exposed Vertical Fan Coil Unit with Angled Discharge (Cooling and Heating)

DeLENG Exposed Vertical Fan Coil Unit with Angled Discharge (Cooling and Heating)

DELENG HVAC · Direct from our Dezhou factory  

DeLENG Exposed Vertical Fan Coil Unit
with Angled Discharge (Cooling & Heating)

DeLENG exposed vertical fan coil unit with angled discharge (cooling and heating), supplied direct from our Dezhou factory: reliable quality, non-standard customisation supported, widely used in hotels and other HVAC ventilation projects.

Cooling & heatingQuietEnergy savingCopperDirect from factory
DeLENG exposed vertical fan coil unit with angled discharge

Product introduction

The exposed angled-discharge fan coil unit (cooling and heating) is a common terminal device in central air-conditioning systems. Working with a chilled and hot water loop, it provides cooling in summer and heating in winter. Units can be specified in horizontal, vertical or cassette configurations to suit the available space, and are widely used in hotels, office buildings, shopping malls, residences and commercial premises.

The DeLENG exposed angled-discharge fan coil unit is compact and flexible to install. Paired with a thermostat it delivers independent temperature control and on-demand start/stop, balancing comfort with energy savings. Non-standard customisation is supported, with fabrication and selection made to project drawings.

Service hotline:0534-2555668

Key features · Why choose the DeLENG exposed vertical angled-discharge fan coil unit

Cooling and heating · Quiet running · Energy saving · Durable copper

C

Cooling & heating

One unit for both seasons: cooling in summer and heating in winter from a chilled and hot water source.

Q

Quiet running

Stable, low-noise operation that suits bedrooms, offices and hotels where quietness matters.

E

Energy saving

Efficient running that reduces long-term operating costs.

C

Copper

Copper key components: good heat transfer, durable and long service life.

FP-LM exposed vertical (angled discharge) fan coil unit technical parameters

1. Performance parameters

Parameter Condition FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Airflow m³/h High 340 510 680 890 1020 1360 1700 2040 2380
Medium 260 390 510 640 770 1020 1280 1530 1790
Low 170 260 340 430 510 680 850 1020 1190
Cooling capacity kW 1.98 2.80 3.87 4.58 5.42 7.38 9.08 11.1 12.9
kcal/h 1702 2408 3328 3938 4661 6346 7808 9546 11094
Heating capacity kW 3.39 4.50 6.35 7.45 9.22 12.4 16.3 19.5 20.2
kcal/h 2915 3870 5460 6407 7930 10665 14020 16770 17370
Input power W 12 Pa 37 52 62 76 96 134 152 189 228
30 Pa 44 59 72 87 108 156 174 212 253
50 Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 12 Pa 37 39 41 43 45 46 48 50 52
30 Pa 40 42 44 46 47 48 50 52 54
50 Pa 42 44 46 47 49 50 52 54 56
Water flow kg/h   350 510 660 800 980 1280 1600 1920 2230
Water resistance kPa   30 30 30 30 40 40 40 40 50
Fan quantity   1 1 1 1 1 3 3 4 4
Water connections: 3/4″ female thread
Condensate drain: 3/4″ male thread
Power supply: 220V / 50Hz

2. Overall dimensions (mm)

Model Length A Outlet section
A-460
FP-34 920 460
FP-51 1040 580
FP-68 1110 650
FP-85 1240 780
FP-102 1360 900
FP-136 1560 1100
FP-170 1820 1360
FP-204 2020 1560
FP-238 2220 1760

All models: overall height 630 mm; body depth 230 mm; height of water and condensate pipes above the base 180 mm; angled-discharge section 120 mm.

Notes: (1) The outlet can be upward-discharge or angled-discharge, at the customer's choice; (2) the condensate outlet direction (rear or bottom) can be selected as required.

3. Installation drawing

DeLENG FP-LM exposed vertical fan coil unit installation and dimension drawing

4. Operating conditions and notes

  1. Cooling condition: entering air dry-bulb 27°C, wet-bulb 19.5°C; entering water 7°C with a 5°C water temperature difference;

  2. Heating condition: entering air dry-bulb 21°C, entering water 60°C, water flow as for the cooling condition;

  3. Pressure: each unit is pressure-tested at 2.0 MPa; maximum working pressure 1.6 MPa;

  4. Four-pipe: four-pipe units (1+1, 2+2, 3+1) are available as an option.

Selection / quotation / technical advice: 0534-2555668 (DeLENG technical department)

Applications

DeLENG exposed vertical angled-discharge fan coil unit · suited to multiple settings

H

Hotels

Guest rooms, corridors, fresh air and air conditioning

O

Offices

Floor-standing, ready to run

R

Renovation

Surface pipework, no ceiling void

C

Classrooms

Vertical airflow, even and comfortable

FAQ

Where is the DeLENG exposed vertical angled-discharge fan coil unit suitable for?

It suits hotels and other HVAC ventilation projects. Dezhou DeLENG, as the source factory, can provide a suitable selection based on the actual project requirements.

Can dimensions and specifications be customised?

Yes. The DeLENG exposed vertical angled-discharge fan coil unit supports non-standard customisation to project drawings: dimensions, materials and surface finish can all be specified as required. Send us your project parameters and we will work through them with you.

Are you the source manufacturer?

Yes. Dezhou DeLENG Air Conditioning Co., Ltd. is a source manufacturer of HVAC equipment, producing and selling directly with no middlemen, with in-house R&D and manufacturing capability and consistent quality.

How about stock and delivery?

DeLENG is a source factory in Dezhou, Shandong, with stock on hand and fast dispatch, and customisation to samples is supported. Call 0534-2555668 for selection advice.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need Exposed Vertical Fan Coil Unit with Angled Discharge?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668