Home›Products ›Heat Recovery Ventilators ›DeLENG Single-flow Quiet Fresh-air Unit (High-efficiency Purification)
DeLENG · factory direct supply

DeLENG Single-flow Quiet Fresh-air Unit (High-efficiency Purification)

Heat recovery ventilators supply fresh air while recovering energy from the exhaust stream through a total heat exchange core, with multi-stage filtration options for hospitals, offices and schools.

DeLENG Single-flow Quiet Fresh-air Unit (High-efficiency Purification)

DeLENG Single-flow Quiet Fresh-air Unit (High-efficiency Purification)

DeLENG single-flow quiet fresh-air unit works on “forced extract, natural supply”: indoor negative pressure draws fresh air in through bedroom and living-room inlets, the air then travels through corridors and door gaps to the kitchen and bathroom and is discharged, renewing the whole home without extra ductwork.

Three filter configurations are available: standard (basic supply and extract), primary filtration (G4 panel filter trapping hair, pollen and coarse dust) and full purification (G4 + coconut-shell activated carbon + HEPA H11, removing PM2.5, formaldehyde, TVOC and decoration odour).

The fan housing contains sound-absorbing foam and a damping layer, and the outlet is fitted with an ABS flexible connector, so operating noise is as low as 35 dB(A). The external-rotor low-noise motor is efficient and long-lived, rated for 24-hour continuous running. A service hatch at the bottom of the housing lets the filter be pulled out for cleaning or replacement.

Service hotline: +86 534 2555668

Key features · Single-flow Quiet Fresh-air Unit (High-efficiency Purification)

Three-stage filtration · High airflow · 38 dB · Metal volute

T

Three-stage filtration

Primary + coconut-shell carbon + HEPA, removal rate 95.2%.

H

High airflow

CADR > 500 m³/h, airflow 300–3000 m³/h.

3

38 dB

Library-quiet operation, 0.5 kWh of electricity per day.

M

Metal volute

One-piece pressed galvanised steel, high static pressure for long duct runs.

Product display

Side view

Top outlet

Inlet and outlet view

Pull-out filter structure

DXFJ Series · Performance Data

Model Airflow (m³/h) External static pressure (Pa) Power (W) Voltage (V) Overall size L×W×H (mm)
DXFJ-03 350 60 60 220 450×385×220
DXFJ-05 500 80 90 220 450×385×220
DXFJ-08 800 100 110 220 560×430×285
DXFJ-10 1000 110 120 220 560×430×285
DXFJ-12 1200 120 150 220 560×430×285
DXFJ-15 1500 150 200 220 570×450×380
DXFJ-20 2000 200 200 220 570×450×380
DXFJ-25 2500 320 300 380 600×550×450
DXFJ-30 3000 550 300 380 600×550×450

Note: figures are for the full-purification version (primary + activated carbon + HEPA); the standard and primary-filtration versions share the same dimensions.

Applications · Single-flow fresh-air purification

H

Hotels

38 dB quiet air renewal

O

Office buildings

High airflow, efficient purification

H

Homes

0.5 kWh per day, energy saving

P

Purification

Three-stage filtration protects breathing

FAQ

Q: How loud is it? Will it disturb sleep when fitted in a bedroom ceiling?
A: Overall noise is as low as 35 dB(A); the high-efficiency purification version measures about 38 dB(A). Sound-absorbing foam and a damping layer sit inside the fan housing and the outlet has an ABS flexible connector, while the external-rotor low-noise centrifugal fan runs 24 hours continuously — installation in a bedroom ceiling does not disturb sleep.

Q: Which version should I choose — standard, primary filtration or full purification?
A: Standard only supplies and extracts air. The primary-filtration version (G4 panel filter) traps hair, pollen and coarse dust. Full purification is G4 + coconut-shell activated carbon + HEPA H11, removing PM2.5, formaldehyde, TVOC and decoration odour.

Q: How are the filters maintained, and how often are they replaced?
A: A service hatch at the bottom of the housing lets the filter be pulled out for cleaning or replacement. The G4 primary filter is washed every 3–6 months (water-washable), activated carbon every 6–12 months and HEPA H11 about once a year, adjusted to outdoor dust levels and running hours.

Q: How do I select a model — airflow, power and size?
A: Size airflow by room volume and occupancy: 350–500 m³/h (DXFJ-03/05, 60–90 W) suits a single room or small apartment; 800–1200 m³/h (DXFJ-08/10/12, 110–150 W) suits larger homes; 1500–3000 m³/h (DXFJ-15 to DXFJ-30) suits whole-house or commercial projects. Send the project parameters and we will confirm the model.

Selection and quotation: +86 534 2555668  |  WeChat +86 534 2555668  |  sales@deleng.com

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need Single-flow Quiet Fresh-air Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top