Fresh-air Total Heat Exchanger

Recovers over 70% of the energy from the exhaust air — pre-cooling and dehumidifying in summer, pre-heating and humidifying in winter; primary plus high-efficiency dual filtration removes over 95% of PM2.5; brushless DC motor runs quietly.

Fresh-air Total Heat Exchanger

Fresh-air Total Heat Exchanger

Dezhou DeLeng Air Conditioning Co., Ltd. is a professional total heat exchange ventilator manufacturer integrating design, R&D, manufacturing and sales. The DeLeng total heat exchange ventilator adopts an advanced heat exchange core with heat recovery efficiency above 70%: pre-cooling and dehumidifying in summer, pre-heating and humidifying in winter, significantly reducing energy consumption while bringing in fresh air.

Each unit is equipped with primary plus high-efficiency dual filtration, with PM2.5 removal efficiency above 95%. A brushless DC motor and an optimised air path deliver low-noise operation. The total heat exchange core is washable and reusable, filters are quick to replace and the interior is easy to clean and service — an ideal choice for commercial and residential ventilation systems.

Service hotline: +86 534 2555668

Features · Total Heat Exchange Ventilator

High-efficiency heat recovery · Dual-stage filtration · Brushless low noise · Easy maintenance

H

High-efficiency heat recovery

The total heat exchange core recovers more than 70% of the energy in the exhaust air — far more economical than ventilating with open windows.

D

Dual-stage filtration

Primary plus high-efficiency two-stage filtration; PM2.5 removal efficiency reaches 95% or more and indoor pollutants are effectively removed.

B

Brushless low noise

Centrifugal fan with sound-absorbing lining; about 30 dB(A) at low speed — bedroom-quiet operation.

E

Easy maintenance

Washable and reusable exchange core, quick filter replacement, interior easy to clean and inspect.

Technical parameters

X Series · Fresh-air Total Heat Exchanger — Detailed Specifications

Airflow Overall size (mm) Static pressure Connection size Power Voltage Heat recovery efficiency Noise
150m³/h 1060×750×260 80Pa Φ150 25W×2 220V 75% 39db
300m³/h 1060×750×260 80Pa Φ150 35W×2 220V 75% 40db
500m³/h 1060×750×260 120Pa Φ150 40W×2 220V 75% 42db
800m³/h 1200×850×350 120Pa Φ200 80W×2 220V 75% 43db
1000m³/h 1200×850×350 120Pa Φ200 80W×2 220V 75% 43db
1500m³/h 1360×900×400 245Pa Φ250 150W×2 220V 75% 45db
2000m³/h 1360×1120×470 280Pa Φ300/300×200 250W×2 220V 75% 48db
2500m³/h 1460×1280×480 340Pa 350×250 0.37KW×2 380V 75% 58db
3000m³/h 1460×1300×480 300Pa 350×250 0.55KW×2 380V 75% 60db
4000m³/h 1430×1300×510 400Pa 400×250 0.8KW×2 380V 75% 60db
5000m³/h 1620×1300×560 500Pa 450×300 1.3KW×2 380V 75% 63db
6000m³/h 1690×1660×560 550Pa 450×350 1.5KW×2 380V 75% 65db
7000m³/h 1915×1720×645 340Pa 500×400 1.5KW×2 380V 75% 61db
8000m³/h 1960×1720×645 300Pa 500×400 1.8KW×2 380V 75% 63db
10000m³/h 2140×1720×745 800Pa 600×450 3KW×2 380V 75% 75db

Overall dimensions

Total heat exchange ventilator overall dimensions: width, length, height

Sizes in mm. Overall size, connection size and mounting position are all shown in the drawing above; dimensions vary with the airflow class selected in the table.

Duct Layout

Total heat exchanger · four connection arrangements A / B / C / D

Total heat exchanger duct layout, four connection arrangements A B C D

Note: A and B are straight-through arrangements, C and D are cross-flow; see the diagram for fresh air, supply air, return air and exhaust air positions. Site installation shall follow the unit labels and the supplied manual.

Applications · Fresh air for enclosed spaces

C

Commercial buildings

Ventilation and energy saving for offices and commercial buildings

H

Healthcare

Clean fresh air for hospitals and clinics

E

Education

Fresh air systems for schools and classrooms

R

Residential

Fresh air for apartments, villas and homes

FAQ

What is the difference between a total heat exchanger and a standard fresh-air ventilator?

A standard ventilator brings outdoor air straight in, so the full heat load of summer air enters the room. A total heat exchanger recovers the cooling or heating energy of the exhaust air through its core and pre-cools or pre-heats the incoming fresh air; recovery efficiency is above 70%, cutting air-conditioning energy use roughly in half.

How do I choose the filtration grade?

G4 primary filtration is enough for ordinary offices. Hospitals, laboratories and clean workshops add H11/H13 high-efficiency filters, with PM2.5 removal above 95%. DeLENG can configure the filtration stage to suit the project.

How often are the core and filters replaced?

The total heat exchange core is washable and reusable, cleaned every 6-12 months. Primary filters are replaced every 1-3 months and high-efficiency filters every 6-12 months, depending on on-site dust levels.

How noisy is it – can it be used in a bedroom?

With a centrifugal fan and sound-absorbing duct lining, the 150-500 m3/h models run at about 30-35 dB(A) on low speed, as quiet as a library. Larger units are best mounted in a plant room or corridor ceiling.

For price, drawings or selection help, call +86 534 2555668, WeChat +86 534 2555668 or email sales@deleng.com.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need a fresh-air Total Heat Exchanger?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top