Recovers over 70% of the energy from the exhaust air — pre-cooling and dehumidifying in summer, pre-heating and humidifying in winter; primary plus high-efficiency dual filtration removes over 95% of PM2.5; brushless DC motor runs quietly.

Dezhou DeLeng Air Conditioning Co., Ltd. is a professional total heat exchange ventilator manufacturer integrating design, R&D, manufacturing and sales. The DeLeng total heat exchange ventilator adopts an advanced heat exchange core with heat recovery efficiency above 70%: pre-cooling and dehumidifying in summer, pre-heating and humidifying in winter, significantly reducing energy consumption while bringing in fresh air.
Each unit is equipped with primary plus high-efficiency dual filtration, with PM2.5 removal efficiency above 95%. A brushless DC motor and an optimised air path deliver low-noise operation. The total heat exchange core is washable and reusable, filters are quick to replace and the interior is easy to clean and service — an ideal choice for commercial and residential ventilation systems.
Service hotline: +86 534 2555668
High-efficiency heat recovery · Dual-stage filtration · Brushless low noise · Easy maintenance
The total heat exchange core recovers more than 70% of the energy in the exhaust air — far more economical than ventilating with open windows.
Primary plus high-efficiency two-stage filtration; PM2.5 removal efficiency reaches 95% or more and indoor pollutants are effectively removed.
Centrifugal fan with sound-absorbing lining; about 30 dB(A) at low speed — bedroom-quiet operation.
Washable and reusable exchange core, quick filter replacement, interior easy to clean and inspect.
| Airflow | Overall size (mm) | Static pressure | Connection size | Power | Voltage | Heat recovery efficiency | Noise |
|---|---|---|---|---|---|---|---|
| 150m³/h | 1060×750×260 | 80Pa | Φ150 | 25W×2 | 220V | 75% | 39db |
| 300m³/h | 1060×750×260 | 80Pa | Φ150 | 35W×2 | 220V | 75% | 40db |
| 500m³/h | 1060×750×260 | 120Pa | Φ150 | 40W×2 | 220V | 75% | 42db |
| 800m³/h | 1200×850×350 | 120Pa | Φ200 | 80W×2 | 220V | 75% | 43db |
| 1000m³/h | 1200×850×350 | 120Pa | Φ200 | 80W×2 | 220V | 75% | 43db |
| 1500m³/h | 1360×900×400 | 245Pa | Φ250 | 150W×2 | 220V | 75% | 45db |
| 2000m³/h | 1360×1120×470 | 280Pa | Φ300/300×200 | 250W×2 | 220V | 75% | 48db |
| 2500m³/h | 1460×1280×480 | 340Pa | 350×250 | 0.37KW×2 | 380V | 75% | 58db |
| 3000m³/h | 1460×1300×480 | 300Pa | 350×250 | 0.55KW×2 | 380V | 75% | 60db |
| 4000m³/h | 1430×1300×510 | 400Pa | 400×250 | 0.8KW×2 | 380V | 75% | 60db |
| 5000m³/h | 1620×1300×560 | 500Pa | 450×300 | 1.3KW×2 | 380V | 75% | 63db |
| 6000m³/h | 1690×1660×560 | 550Pa | 450×350 | 1.5KW×2 | 380V | 75% | 65db |
| 7000m³/h | 1915×1720×645 | 340Pa | 500×400 | 1.5KW×2 | 380V | 75% | 61db |
| 8000m³/h | 1960×1720×645 | 300Pa | 500×400 | 1.8KW×2 | 380V | 75% | 63db |
| 10000m³/h | 2140×1720×745 | 800Pa | 600×450 | 3KW×2 | 380V | 75% | 75db |

Sizes in mm. Overall size, connection size and mounting position are all shown in the drawing above; dimensions vary with the airflow class selected in the table.
Total heat exchanger · four connection arrangements A / B / C / D

Note: A and B are straight-through arrangements, C and D are cross-flow; see the diagram for fresh air, supply air, return air and exhaust air positions. Site installation shall follow the unit labels and the supplied manual.
Ventilation and energy saving for offices and commercial buildings
Clean fresh air for hospitals and clinics
Fresh air systems for schools and classrooms
Fresh air for apartments, villas and homes
A standard ventilator brings outdoor air straight in, so the full heat load of summer air enters the room. A total heat exchanger recovers the cooling or heating energy of the exhaust air through its core and pre-cools or pre-heats the incoming fresh air; recovery efficiency is above 70%, cutting air-conditioning energy use roughly in half.
G4 primary filtration is enough for ordinary offices. Hospitals, laboratories and clean workshops add H11/H13 high-efficiency filters, with PM2.5 removal above 95%. DeLENG can configure the filtration stage to suit the project.
The total heat exchange core is washable and reusable, cleaned every 6-12 months. Primary filters are replaced every 1-3 months and high-efficiency filters every 6-12 months, depending on on-site dust levels.
With a centrifugal fan and sound-absorbing duct lining, the 150-500 m3/h models run at about 30-35 dB(A) on low speed, as quiet as a library. Larger units are best mounted in a plant room or corridor ceiling.
For price, drawings or selection help, call +86 534 2555668, WeChat +86 534 2555668 or email sales@deleng.com.

Product display
View details →

Product display
View details →

Product display
View details →

Product display
View details →
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.