Heat recovery ventilators supply fresh air while recovering energy from the exhaust stream through a total heat exchange core, with multi-stage filtration options for hospitals, offices and schools.

DeLENG vertical fresh-air heat recovery unit (total heat exchange, energy-saving type) is built around an external-rotor centrifugal fan, covering 2,000 to 15,000 m³/h. Cabinet sizes run from 900×450×1250 mm to 2200×950×2400 mm, with motor power 1,100–8,000 W at 380 V.
The core is a total heat exchange element: inlet duct 400×300 mm up to 800×630 mm, outlet duct 300×250 mm up to 700×500 mm, both ready for duct connection. The housing uses 1.2 mm thickened galvanised steel and pull-out filters for easy maintenance.
Service hotline: +86 534 2555668
Total heat exchange · High airflow · Thickened steel plate · Pull-out filter
Total heat exchange element recovers energy from exhaust air.
External-rotor centrifugal fan, 2,000–15,000 m³/h.
1.2 mm thickened galvanised steel housing.
Pull-out filters, easy to clean and service.
Total heat exchange energy-saving type · fast air change · healthy and eco-friendly, custom sizes available for projects.
| Airflow (m³/h) | Dimensions L×W×H (mm) | Power (W) | Inlet W×H (mm) | Outlet W×H (mm) | Voltage |
|---|---|---|---|---|---|
| 2000 | 900×450×1250 | 1100 | 400×300 | 300×250 | 380V |
| 2500 | 1000×500×1250 | 1500 | 400×300 | 300×250 | 380V |
| 3000 | 1200×550×1400 | 1600 | 500×400 | 350×300 | 380V |
| 4000 | 1400×600×1600 | 2200 | 500×400 | 400×300 | 380V |
| 5000 | 1500×700×1700 | 3000 | 600×400 | 450×300 | 380V |
| 6000 | 1600×700×1800 | 3600 | 630×400 | 500×400 | 380V |
| 8000 | 1700×750×1900 | 4400 | 650×500 | 500×400 | 380V |
| 10000 | 1900×750×2100 | 6000 | 650×600 | 600×500 | 380V |
| 15000 | 2200×950×2400 | 8000 | 800×630 | 700×500 | 380V |
Note: power figures are unit input power; cabinet sizes and filter grade can be customised to project requirements.

DeLENG vertical fresh-air heat recovery unit — length / width / height and inlet / outlet duct dimensions (unit: mm)
Total heat exchange energy-saving fresh air
Pull-out filter purification
High-airflow ventilation
380 V commercial power
Q: How do I choose between vertical and horizontal units?
A: Vertical units are floor-standing and take little floor area — good for plant rooms, equipment rooms and corridor corners. Horizontal units are suspended inside the ceiling void and free up floor space. Choose vertical when space is tight, horizontal when the ceiling has spare depth.
Q: How much power does the total heat exchange type actually save?
A: The total heat exchange core recovers more than 70% of the cooling or heating energy in the exhaust air: outdoor air no longer has to be fully cooled in summer or fully heated in winter. Overall air-conditioning energy use drops by 40%–60%, and payback is fastest in hotels and shopping malls running continuously.
Q: How often do filters need changing, and how is the core cleaned?
A: Primary filters every 1–3 months, secondary filters every 3–6 months. The total heat exchange core can be pulled out and rinsed with a low-pressure water gun, then dried and refitted — once a year is recommended.
Q: What about voltage and installation?
A: 2,000–5,000 m³/h models can be ordered in 220 V or 380 V; 8,000 m³/h and above are 380 V three-phase by default. Connect the inlet and outlet to flexible ducts to isolate vibration, mount the unit on a concrete or channel-steel base, and leave 600 mm service space beside it.
Selection and quotation: +86 534 2555668 | WeChat +86 534 2555668 | sales@deleng.com
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.