Product introduction

This product is the Dezhou DeLENG exposed horizontal fan coil unit, covering every model from 34WM to 238WM: all share a uniform 500 mm width and 240 mm height, while the length changes with the model (34WM is 860 mm long for 5-10 m², 51WM is 980 mm long for 10-15 m², up to the 238WM at 2160 mm long for 55-60 m²).

Motor power runs from 10 to 60 × 2 W, and the number of motors and fans increases with model size. It uses an inclined wide-angle discharge design together with quality galvanised steel sheet and electrostatic powder coating (corrosion-resistant and durable), an enlarged air outlet (high airflow) and a removable dense filter (easy to clean). At its core are a hydrophilic-fin pure copper tube coil (efficient heat exchange) and a copper-core motor (powerful and quiet), with left- or right-hand water connections available.

Service hotline:0534-2555668

Key features · Why choose the DeLENG exposed horizontal wide-angle fan coil unit (pure copper tube, quiet)

Wide-angle airflow · Pure copper coil · Copper-core motor · Removable filter

W

Wide-angle airflow

Inclined wide-angle discharge for comfortable cooling and heating without direct drafts.

P

Pure copper heat exchange

Hydrophilic-fin pure copper tubes for efficient heat exchange.

C

Copper-core motor

A powerful, quiet copper-core motor with an enlarged air outlet for high airflow.

R

Removable filter

A removable dense filter that is easy to clean, with left or right water connections.

Core selling points of the wide-angle exposed fan coil unit

Inclined wide-angle airflow from a quiet fan for low-noise comfort
Enlarged air outlet delivering higher airflow and more comfort
Dense removable filter, easy to take out and wash for healthier air

Wide-angle exposed fan coil unit technical performance data

Inclined discharge design · enlarged air outlet · pure copper tube

Performance Model FP-34WM FP-51WM FP-68WM FP-85WM FP-102WM FP-136WM FP-170WM FP-204WM FP-238WM
Airflow m³/h High 340 510 680 850 1020 1360 1700 2040 2380
Medium 255 383 510 638 765 1020 1275 1530 1785
Low 170 255 340 425 510 680 850 1020 1190
Cooling capacity W High 1800 2700 3600 4500 5400 7200 9000 10800 12600
Medium 1440 2160 2880 3600 4320 5760 7200 8640 10080
Low 1170 1755 2340 2925 3510 4680 5850 7020 8190
Heating capacity W High 2700 4050 5400 6750 8100 10800 13500 16200 18900
Medium 2160 3240 4320 5400 6480 8640 10800 12960 15120
Low 1755 2633 3510 4388 5265 7020 8775 10530 12285
Input power W 12Pa 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 12Pa 37 39 41 43 45 46 48 50 52
30Pa 40 42 44 46 47 48 50 52 54
50Pa 42 44 46 47 49 50 52 54 56
Water flow m³/h 0.39 0.55 0.70 0.82 0.91 1.34 1.59 1.80 2.07
Water resistance kPa 12 16 20 23 26 28 32 38 42
Weight kg (FP-WM) 23 27 29 30 33 46 52 55 64
Power supply Single phase 220V / 50Hz

Wide-angle exposed fan coil unit overall dimensions

Wide-angle exposed fan coil unit overall dimensions - length, width, height
 

L / W / H in mm · Area in m² · M = motor, F = fan

Model L
mm
W
mm
H
mm
Area
m²
Power
W
Motor
& fan
FP-34WM 860 500 240 5-10 10 1M·1F
FP-51WM 980 500 240 10-15 20 1M·2F
FP-68WM 1050 500 240 15-20 25 1M·2F
FP-85WM 1180 500 240 20-25 35 1M·2F
FP-102WM 1300 500 240 25-30 50 1M·2F
FP-136WM 1500 500 240 30-40 16/35 2M·3F
FP-170WM 1760 500 240 40-50 35×2 2M·4F
FP-204WM 1960 500 240 50-55 40×2 2M·4F
FP-238WM 2160 500 240 55-60 60×2 2M·4F

Applications · Exposed horizontal heating and cooling

R

Residential

Comfortable wide-angle inclined airflow

H

Hotel

Quiet operation with high airflow

O

Office

Removable filter for easy cleaning

C

Commercial

Flexible left or right water connections

FAQ

Q: How much does this fan coil unit cost?

A: We supply direct from the factory. Please contact Manager Wei on +86 135 8341 6899.

Q: How long is the warranty?

A: A 3-year warranty on the complete unit and 5 years on the copper motor.

Q: What are the benefits of wide-angle airflow?

A: The inclined wide-angle discharge reaches a wider area and avoids blowing directly onto people, for comfortable cooling and heating.

Q: Which places suit a wide-angle fan coil unit?

A: Hotel lobbies, shopping malls, exhibition halls, offices and other large spaces – the inclined wide-angle airflow covers a wider area, avoids direct drafts and keeps heating and cooling more even and comfortable.

Q: Is the filter easy to clean?

A: The filter is removable – simply pull it out and rinse it, which makes routine maintenance easy and keeps the supply air clean.

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need Exposed Horizontal Wide-angle Fan Coil Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top