Home›Products ›Exposed Horizontal FCU ›Right-angle Exposed Horizontal Fan Coil Unit

Right-angle Exposed Horizontal Fan Coil Unit

DELENG HVAC · Direct from our Dezhou factory  

Right-angle Exposed Horizontal Fan Coil Unit

The DeLENG right-angle exposed horizontal fan coil unit is compact in design and easy to hang beneath the ceiling without taking up space. Its electrostatically powder-coated casing harmonises with interior decoration, which makes it well suited to old-building retrofit.

Hangs under the ceilingPowder-coated casingOld-building retrofitFewer pipe runsFactory direct  
Right-angle exposed horizontal fan coil unit - DeLENG HVAC

Product introduction

The DeLENG right-angle exposed horizontal fan coil unit, with its excellent design and performance, is a preferred choice for indoor air-conditioning systems. It can be ideally hung anywhere beneath the ceiling, takes up no valuable indoor floor area, and is easy to install.

The casing is electrostatically powder-coated in harmonious colours that blend with the interior. It suits air-conditioning retrofit of old buildings: its distinctive design significantly reduces pipe runs and therefore cuts installation cost. In both homes and commercial premises, DeLENG fan coil units deliver comfortable and efficient air conditioning.

Service hotline:0534-2555668

Key features · Why choose the right-angle exposed unit

Hangs under the ceiling · Powder-coated casing · Retrofit friendly · Quiet operation

H

Hangs anywhere under the ceiling

It can be hung anywhere under the ceiling, uses no valuable indoor floor area and is easy to install.

P

Powder-coated casing

The casing is electrostatically powder-coated in colours that blend with the interior decoration.

I

Ideal for old-building retrofit

The distinctive design significantly reduces pipe runs and greatly lowers the installation cost of air-conditioning retrofit in old buildings.

L

Low-noise operation

A copper-core quiet motor with a dynamically balanced fan wheel keeps low-speed noise to only 35-40 dB(A), suitable for hotels and offices.

Exposed horizontal fan coil unit performance data

High-purity copper tubes with W-shaped aluminium fins, mechanically expanded · working pressure 1.6 MPa

Performance Model FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Airflow m³/h High 340 510 680 850 1020 1360 1700 2040 2380
Medium 255 383 510 638 765 1020 1275 1530 1785
Low 170 255 340 425 510 680 850 1020 1190
Cooling capacity W High 1800 2700 3600 4500 5400 7200 9000 10800 12600
Medium 1440 2160 2880 3600 4320 5760 7200 8640 10080
Low 1170 1755 2340 2925 3510 4680 5850 7020 8190
Heating capacity W High 2700 4050 5400 6750 8100 10800 13500 16200 18900
Medium 2160 3240 4320 5400 6480 8640 10800 12960 15120
Low 1755 2633 3510 4388 5265 7020 8775 10530 12285
Input power W 12Pa 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 12Pa 37 39 41 43 45 46 48 50 52
30Pa 40 42 44 46 47 48 50 52 54
50Pa 42 44 46 47 49 50 52 54 56
Water flow m³/h 0.39 0.55 0.70 0.82 0.91 1.34 1.59 1.80 2.07
Water resistance kPa 12 16 20 23 26 28 32 38 42
Weight kg (FP-WM) 23 27 29 30 33 46 52 55 64
Water pipe connection Rc3/4 female thread
Condensate pipe R3/4 male thread
Power supply Single phase 220V / 50Hz

Exposed horizontal fan coil unit overall dimensions

Exposed horizontal fan coil unit overall dimensions A overall length, C outlet length, water outlet / inlet / condensate
Right-angle exposed horizontal fan coil unit mounting holes - B hanger hole spacing, 4-Φ10×20 holes, terminal block
Model FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
A Overall length (mm) 845 965 1035 1165 1285 1485 1745 1945 2145
B Hanger hole spacing (mm) 490 610 680 810 930 1130 1390 1590 1790
C Outlet length (mm) 448 568 638 768 888 1088 1348 1548 1748

Note: unit height 240 mm, outlet height 120 mm, depth 500 mm. Hanger holes 4-Φ10×20; water inlet / outlet Rc3/4, condensate pipe R3/4; the terminal block is on the side of the unit.

Product Photos · Right-angle Exposed Horizontal Fan Coil Unit

Real shots from the Deleng workshop: casing structure, return air panel and end-panel connections from four angles

Right-angle exposed horizontal fan coil unit - top discharge grille and return air panel Right-angle exposed horizontal fan coil unit - front return air panel and casing Right-angle exposed horizontal fan coil unit - side profile and end connections Right-angle exposed horizontal fan coil unit - end panel controls and wiring

Applications · Indoor air conditioning

R

Residential homes

Comfortable and efficient indoor air conditioning

C

Commercial spaces

Terminal units for shops, offices and other commercial spaces

O

Old-building retrofit

Fewer pipe runs, lower retrofit cost

H

Hotels and offices

Quiet at low speed, comfortable and calm

FAQ

Q: How much does this fan coil unit cost?

A: DeLENG supplies fan coil units direct from the factory. Prices differ by model and configuration; for a quotation please contact Manager Wei on +86 135 8341 6899.

Q: How long is the warranty?

A: The complete DeLENG unit carries a 3-year warranty, the copper-core motor 5 years, and the coil is guaranteed leak-free for 5 years.

Q: Is the fan coil unit noisy?

A: A copper-core quiet motor with a dynamically balanced fan wheel keeps low-speed noise to only 35-40 dB(A), suitable for hotels and offices.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need a right-angle Exposed Horizontal Fan Coil Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top