Home›Products ›Axial Fans ›Axial Smoke Extract Fan

Axial Smoke Extract Fan

Deleng Air Conditioning · Direct from the manufacturer  

Axial Smoke Extract Fan

Deleng axial smoke extract fans combine axial and centrifugal advantages, use dynamically balanced high-quality steel and a high-temperature motor with a cooling system — for smoke extraction in buildings, malls, basements and tunnels.

Fire smoke extractionHigh-temperature motor + cooling systemHigh pressure, high airflowDynamically balancedLow noise, energy saving  
Axial smoke extract fan — Deleng air conditioning equipment

Product Introduction

Deleng axial smoke extract fans combine the advantages of axial and centrifugal fans — high pressure, large airflow, high efficiency, low noise, energy saving and easy installation — making them an efficient solution for smoke extraction systems. Built from high-quality steel and precisely dynamically balanced, the fan runs smoothly and quietly.

A high-temperature motor drives the impeller directly, and a built-in cooling system keeps the motor working normally during long high-temperature operation. It suits the smoke extraction needs of office buildings, hotels, residential buildings, shopping malls, hospitals, basements and tunnels.

Service hotline:+86 534 2555668

Product Features · Why choose an axial smoke extract fan

High-temperature motor cooling · Thickened anti-corrosion casing · Copper-wire high efficiency and low noise · Steady and durable

H

High-temperature motor cooling

A high-temperature motor drives the impeller directly and a built-in cooling system keeps long high-temperature smoke extraction running normally.

T

Thickened anti-corrosion casing

Thickened carbon steel casing with a painted finish: wear-resistant, corrosion-resistant, shock-proof and drop-resistant.

C

Copper-wire high efficiency and low noise

Purpose-built pure copper-wire fan motor: sound structure, good heat dissipation, smooth running and low noise.

S

Steady and durable

Moulded hub, curved blades and thickened plate: steadier and more durable operation.

Product Details

Visible quality details, built to satisfy you

Selling point 1 — thickened casing
Thickened casing
Thickened carbon steel casing with a painted finish: wear-resistant, corrosion-resistant, shock-proof and drop-resistant.
Selling point 2 — no corrosion or rusting
No corrosion or rusting
Moulded hub, curved blades and thickened plate make operation steadier and more durable.
Selling point 3 — pure copper-wire motor
Pure copper-wire motor
Purpose-built fan motor with a sound structure and good heat dissipation; copper-wire windings give a long service life.
Selling point 4 — fan guide vane
Fan guide vane
The carbon steel plate is pressed into an arc to increase the guide vane curvature and improve support, cutting air resistance for smoother airflow.

HTF-I Axial Smoke Extract Fan (Single-speed)

HTF-I Axial Smoke Extract Fan Performance Data

Model No. Impeller diameter
(mm)
Recommended airflow
(m³/h)
Recommended total pressure
(Pa)
Speed
(r/min)
Power
(kW)
Noise
dB(A)
Reference weight
(kg)
3.5-1 350 3773 173 2900 1.1 Y80R-2 ≤79 45
3444 317
3080 440
2668 538
1886 583
4-1 400 6162 372 2900 1.5 Y90S-2 ≤85 50
5866 426
5466 492
4748 557
3927 601
4.5-1 450 8677 436 2900 2.2 Y90L-2 ≤88 56
7821 543
6860 650
6136 698
4850 745
5-1 500 10287 413 2900 3 Y100L-2 ≤89 74
8968 605
7969 703
5820 850
2910 1048
5.5-1 550 12710 402 2900 4 Y112M-2 ≤90 87
11369 489
8987 809
6962 959
4020 1175
6-1 600 16275 476 2900 5.5 Y132S-2 ≤92 129
15004 703
12607 954
9629 1100
7277 1150
6.5-1 650 19143 412 1450 4 Y112M-4 ≤83 108
17773 466
16673 512
15494 564
14217 637
7-1 700 24442 552 1450 5.5 Y132S-4 ≤87 147
23186 603
21402 669
19450 721
17281 756
8-1 800 31471 548 1450 7.5 Y132M-4 ≤88 173
29600 626
27599 704
24688 774
19515 842
9-1 900 39022 506 1450 11 Y160M-4 ≤89 248
35810 650
31012 814
25319 884
18953 973
10-1 1000 45545 486 960 11 Y160L-6 ≤86 270
42469 538
37985 595
34238 647
28490 700
11-1 1100 54958 471 960 15 Y180L-6 ≤88 345
51823 517
48326 582
43229 640
34170 725
12-1 1200 64525 476 960 15 Y180L-6 ≤91 360
58648 622
50158 750
42550 806
26902 850
13-1 1300 75336 454 960 18.5 Y200L,-6 ≤92 467
64654 655
51843 777
34561 820
17280 904
14-1 1400 87087 481 960 22 Y200L₂-6 ≤93 517
76161 658
63363 811
51737 841
29872 972
15-1 1500 67034 291 720 22 Y225M-8 ≤90 581
54968 332
50946 367
46924 382
26198 433
16-1 1600 116768 530 720 30 Y250M-8 ≤94 740
109226 619
98275 716
85938 769
71505 843

HTF-II Axial Smoke Extract Fan (Single-speed)

HTF-II Axial Smoke Extract Fan Performance Data

Model No. Impeller diameter
(mm)
Recommended airflow
(m³/h)
Recommended total pressure
(Pa)
Speed
(r/min)
Power
(kW)
Noise
dB(A)
Reference weight
(kg)
4-II 400 7320 490 2900 2.2 Y90L-2 ≤86 53
6830 651
6501 803
5919 903
5224 1012
4.5-II 450 9897 556 2900 3 Y100L-2 ≤87 70
9164 760
8365 927
7483 1023
6480 1089
5-II 500 12083 498 2900 4 Y112M-2 ≤90 81
11249 659
9360 1008
6976 1152
3120 1286
5.5-II 550 17656 839 2900 7.5 Y132S₂-2 ≤93 125
15791 1165
13676 1398
11167 1522
7897 1580
6-II 600 20829 747 2900 11 Y160M₁-2 ≤93 182
19392 989
16134 1512
12025 1729
5379 1930
6.5-II 650 25893 877 2900 15 Y160M₂-2 ≤95 203
24106 1162
20056 1776
14949 2031
6687 2266
7-II 700 26251 654 1450 15 Y160M-4 ≤89 227
24438 781
22985 852
21432 915
19761 945
8-II 800 36356 745 1450 15 Y160L-4 ≤93 238
33444 924
30249 1146
27615 1241
24699 1304
9-II 900 45424 732 1450 15 Y160L-4 ≤93 252
41684 896
37574 1088
34558 1156
29475 1207
10-II 1000 55569 687 1450 18.5 Y180M-4 ≤92 314
51733 824
47588 942
43043 1112
35145 1192
11-II 1100 64085 610 960 22 Y200L2-6 ≤93 411
58950 754
53323 940
48677 1017
43537 1068
12-II 1200 74567 625 960 30 Y225M-6 ≤94 481
69290 866
63530 1023
57313 1169
50266 1240
13-II 1300 91915 688 960 30 Y225M-6 ≤97 533
84347 843
76030 1024
69937 1087
59642 1137
14-II 1400 114829 798 960 45 Y280S-6 ≤98 836
105377 977
94925 1188
86965 1261
74514 1381

HTF-SI Axial Smoke Extract Fan (Two-speed)

HTF-SI Axial Smoke Extract Fan Performance Data

Model No. Impeller diameter
(mm)
Recommended airflow
(m³/h)
Recommended total pressure
(Pa)
Speed
(r/min)
Power
(kW)
Noise
dB(A)
Reference weight
(kg)
4.5-SI 450 7499 334 2900 1.9/0.4 YDT90L -2/4 ≤88 57
6538 490
5809 569
4242 688
2121 848
3750 83 1450 ≤71
3269 122
2904 142
2121 172
1060 212
5-SI 500 10287 413 2900 3.1/0.8 YDT100L -2/4 ≤89 76
8968 605
7969 703
5820 850
2910 1048
5197 105 1450 ≤73
4531 155
4026 180
2940 217
1470 268
6-SI 600 16275 476 2900 5.9/1.4 YDT132S -2/4 ≤92 127
15004 703
12607 954
9629 1100
7277 1150
8138 119 1450 ≤78
7502 178
6304 239
4815 275
3639 288
7-SI 700 25121 583 1450 6.7/2.2 YDT132M -4/6 ≤87 165
23830 634
21997 707
19990 762
17761 799
16634 255 960 ≤81
15779 278
14565 310
13237 334
11760 350
8-SI 800 32345 579 1450 9.5/3.7 YDT160M -4/6 ≤88 229
30422 661
28365 744
25373 818
20057 889
21418 254 960 ≤78
20144 290
18782 326
16801 359
13281 390
9-SI 900 39556 520 1450 12/4 YDT160L- 4/6 ≤89 269
36300 668
31437 836
25666 908
9076 1000
26192 228 960 ≤81
24036 293
20816 367
16995 398
6010 438
10-SI 1000 46015 496 960 12/5.5 YDT180L- 6/8 ≤86 331
42907 549
38377 607
34591 660
28784 715
34276 275 720 ≤80
31961 305
28587 337
25767 366
21441 397
11-SI 1100 55525 480 960 YDT200L 6/8 ≤88 409
52357 527
48824 594
43675 653
34552 740
41360 266 720 ≤81
39000 292
36369 329
32533 362
25715 411
12-SI 1200 65190 486 960 17/8 YDT200L 6/8 ≤91 420
59253 635
50675 765
42989 823
27179 867
48560 269 720 ≤84
44137 352
37747 424
32022 456
20245 481
13-SI 1300 76112 463 960 20/10 YDT200L 2 6/8 ≤92 527
65320 669
52377 793
34917 837
17458 923
56695 257 720 ≤84
48657 371
39015 440
26009 464
13004 512
14-SI 1400 87985 491 960 YDT225 M- 6/8 ≤93 595
76946 672
64016 828
52270 858
30180 992
65540 272 720 ≤85
57317 373
47685 459
39836 476
22481 550

HTF-SII Axial Smoke Extract Fan (Two-speed)

HTF-SII Axial Smoke Extract Fan Performance Data

Model No. Impeller diameter
(mm)
Recommended airflow
(m³/h)
Recommended total pressure
(Pa)
Speed
(r/min)
Power
(kW)
Noise
dB(A)
Reference weight
(kg)
6-SII 600 13359 308 1450 2.5/0.9 YDT100L2 -4/6 ≤81 87
12594 406
11353 537
10443 580
9446 636
8846 135 960 ≤75
8339 178
7518 235
6915 254
6255 279
7-SII 700 26251 654 1450 9/3 YDT160M -4/6 ≤90 209
24438 781
22985 852
21432 915
19761 945
17440 289 960 ≤81
16236 345
15270 376
14239 404
13129 417
8-SII 800 36605 755 450 17/5.5 YDT180L -4/6 ≤93 326
33673 937
30456 1162
27804 1258
24864 1322
24403 335 960 ≤86
22448 416
20304 516
18536 559
16578 589
9-SII 900 45735 742 450 17/5.5 YDT180L -4/6 ≤90 339
41969 908
37831 1103
34795 1172
29677 1224
30490 330 960 ≤82
27969 403
25220 490
23197 521
19785 544
10-SII 1000 60177 824 450 24/8 YDT200L -4/6 ≤91 385
56632 943
51870 1151
47712 1305
40690 1389
40118 366 960 ≤84
37755 419
34580 511
31802 580
27127 617
11-SII 1100 64745 622 960 25/12 YDT225M- 6/8 ≤94 488
59557 772
53872 959
49179 1038
43985 1090
48228 345 720 ≤86
44364 428
40129 532
36623 576
32764 605
12-SII 1200 82443 709 960 30/15 YDT250M- 6/8 ≤94 623
77342 900
71867 1055
65953 1174
57115 1273
61411 438 720 ≤86
57611 499
53533 585
49128 651
42544 706
13-SII 1300 91915 688 960 30/15 YDT250M- 6/8 ≤96 674
84347 843
76030 1024
69937 1087
59642 1137
68467 382 720 ≤87
62830 467
56634 568
52096 603
44427 630
14-SII 1400 114829 798 960 45/22 YDT280M- 6/8 ≤96 894
105377 977
94925 1188
86965 1261
74514 1318
86707 455 720 ≤88
79570 557
71678 677
65667 719
56265 751

HTF-D Axial Smoke Extract Fan

HTF-D Axial Smoke Extract Fan Performance Data

Model No. Impeller diameter
(mm)
Recommended airflow
(m³/h)
Recommended total pressure
(Pa)
Speed
(r/min)
Power
(kW)
Noise
dB(A)
Reference weight
(kg)
5 500 5220 140 1450 1.1 ≤78 58
4860 210
3950 230
5.5 550 7250 115 1450 1.5 ≤78 65
6840 220
5420 230
6 600 11000 152 1450 1.5 ≤79 72
9120 250
7840 300
6.5 650 14580 190 960 2.2 ≤82 108
12690 280
10820 320
7 700 17240 270 960 3 ≤84 146
15210 310
10820 350
8 800 23680 230 960 3 ≤85 154
20540 310
16840 350
9 900 28400 250 960 4 ≤86 190
25420 320
21450 350
10 1000 35210 210 960 5.5 ≤87 207
30820 320
25460 350
11 1100 40620 210 960 5.5 ≤88 226
34100 330
30450 350
12 1200 53420 320 720 11 ≤90 355
51480 350
43500 400
13 1300 58540 330 720 11 ≤92 415
53680 400
50410 450
15 1500 72860 350 720 15 ≤93 554
68750 420
58420 480

HTF-I Outline and Installation Dimensions

The outline and installation drawing of this series is shown below; see the dimension table underneath for actual sizes (unit: mm).

HTF-I Outline and Installation Drawing

HTF-I Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 M1 M2 M3 M4 L H 4-Φ
3.5 352 402 422 472 180 280 476 236 4-12
4 402 462 412 462 220 320 466 261 4-12
4.5 452 512 402 462 260 360 466 286 4-12
5 503 563 496 556 300 400 560 311 4-12
5.5 553 613 486 546 340 440 550 337 4-12
6 603 663 616 676 380 480 680 362 4-12
6.5 653 733 516 576 420 520 580 387 4-12
7 703 783 615 675 460 560 680 412 4-16
8 804 884 595 665 540 640 670 462 4-16
9 904 984 735 815 620 720 820 512 4-16
10 1004 1084 735 815 700 800 820 562 4-16
11 1104 1184 785 865 780 880 870 612 4-16
12 1204 1304 785 865 860 960 870 662 4-16
13 1306 1406 854 944 940 1040 950 713 4-20
14 1406 1506 904 994 1020 1120 1000 763 4-20
15 1506 1606 894 994 1100 1200 1000 813 4-20
16 1606 1706 1044 1144 1180 1280 1150 863 4-20

Note: the 4-Φ anchor-bolt holes in the base are left undrilled as an allowance for on-site installation dimensions; the base flange is not drilled at the factory unless required. Special requirements can be made to order.

HTF-II / HTF-D / HTF-SI / HTF-SII Outline and Installation Dimensions

Outline and installation dimensions for each model of this series are listed below (unit: mm); refer to the roof curb mounting drawing during installation.

HTF-II Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 M1 M2 M3 M4 L H 4-Φ
4 402 462 436 486 220 320 490 261 4-12
4.5 452 512 496 556 260 360 560 286 4-12
5 503 563 496 556 300 400 560 311 4-12
5.5 553 613 616 676 340 440 680 337 4-12
6 603 663 766 826 380 480 830 362 4-12
6.5 653 733 766 826 420 520 830 387 4-12
7 703 783 765 825 460 560 830 412 4-16
8 804 884 745 815 540 640 820 462 4-16
9 904 984 735 815 620 720 820 512 4-16
10 1004 1084 785 865 700 800 870 562 4-16
11 1104 1184 885 965 780 880 970 612 4-16
12 1204 1304 885 965 860 960 970 662 4-16
13 1306 1406 854 944 940 1040 950 713 4-20
14 1406 1506 1044 1144 1020 1120 1150 763 4-20

Note: the 4-Φ holes in the base are for reference only; the fan flange is not drilled unless specified by the user. Special requirements can be made to order.

HTF-D Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 M1 M2 M3 M4 L H 4-Φ
5 503 563 426 486 300 400 490 311 4-12
5.5 553 613 426 486 340 440 490 337 4-12
6 603 663 426 486 380 480 490 362 4-12
6.5 653 733 516 576 420 520 580 387 4-12
7 703 783 605 665 460 560 670 830 4-16
8 804 884 595 665 540 640 670 462 4-16
9 904 984 585 665 620 720 670 512 4-16
10 1004 1084 585 665 700 800 670 562 4-16
11 1104 1184 585 665 780 880 670 612 4-16
12 1204 1304 785 865 860 960 870 662 4-16
13 1306 1406 774 864 940 1040 870 713 4-20
15 1506 1606 1044 1144 1100 1200 1150 813 4-20

Note: the 4-Φ holes in the base are for reference only; the fan flange is not drilled unless specified by the user. Special requirements can be made to order.

HTF-SI Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 M1 M2 M3 M4 L H 4-Φ
4.5 452 512 426 486 260 360 490 286 4-12
5 503 563 496 556 300 400 560 311 4-12
6 603 663 616 676 380 480 680 362 4-12
7 703 783 615 675 460 560 680 412 4-16
8 804 884 745 815 540 640 820 462 4-16
9 904 984 735 815 620 720 820 512 4-16
10 1004 1084 785 865 700 800 870 562 4-16
11 1104 1184 885 965 780 880 970 612 4-16
12 1204 1304 885 965 860 960 970 662 4-16
13 1306 1406 854 944 940 1040 950 713 4-20
14 1406 1506 904 994 1020 1120 1000 763 4-20

Note: the base drilling (4-Φ) is for reference only and suits 4/6/8-pole motors; the flange is not drilled unless required. Special requirements can be made to order.

HTF-SII Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 M1 M2 M3 M4 L H 4-Φ
6 603 663 516 576 380 480 580 362 4-12
7 703 783 765 825 460 560 830 830 4-16
8 804 884 795 865 540 640 870 462 4-16
9 904 984 785 865 620 720 870 512 4-16
10 1004 1084 885 965 700 800 970 562 4-16
11 1104 1184 885 965 780 880 970 612 4-16
12 1204 1304 1035 1115 860 960 1120 662 4-16
13 1306 1406 1004 1094 940 1040 1100 713 4-20
14 1406 1506 1154 1244 1020 1120 1250 763 4-20

Note: the base drilling (4-Φ) is for reference only and suits 4/6/8-pole motors; the flange is not drilled unless required. Special requirements can be made to order.

Roof Curb Mounting Drawing

HTF Vertical Series (-L) Outline and Installation Dimensions

Outline and installation dimensions of the four vertical (-L) models of this series are listed below (unit: mm).

HTF-I-L Vertical Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 A B C H H1 4-Φ L
3.5 352 402 560 450 560 200 40 4-12.5 476
4 402 462 600 490 600 200 40 4-12.5 466
4.5 452 512 650 540 650 200 40 4-12.5 466
5 503 563 700 590 700 200 40 4-14.5 560
5.5 553 613 750 640 750 200 40 4-14.5 550
6 603 663 800 690 800 200 40 4-16.5 680
6.5 653 733 850 740 850 200 40 4-16.5 580
7 703 783 950 820 950 200 40 4-16.5 680
8 804 884 1050 920 1050 200 40 4-16.5 670
9 904 984 1150 1020 1150 200 40 4-16.5 820
10 1004 1084 1250 1120 1250 200 60 4-16.5 820
11 1104 1184 1400 1240 1400 200 60 4-16.5 870
12 1204 1304 1500 1340 1600 200 60 4-16.5 870
13 1306 1406 1600 1440 1700 200 60 4-16.5 950
14 1406 1506 1700 1540 1800 200 60 4-16.5 1000
15 1506 1606 1800 1640 1900 200 60 4-16.5 1000
16 1606 1706 1900 1740 2000 200 60 4-16.5 1150

Note: the drilling in the base plate is an allowance within Φ-Φ; the fan assembly of this series normally cannot be opened on site. Special requirements can be made to order.

HTF-SI-L Vertical Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 A B C H H1 4-Φ L
4.5 452 512 650 540 650 200 40 4-12.5 490
5 503 563 700 590 700 200 40 4-14.5 560
6 603 663 800 690 800 200 40 4-16.5 680
7 703 783 950 820 950 200 40 4-16.5 680
8 804 884 1050 920 1050 200 40 4-16.5 820
9 904 984 1150 1020 1150 200 40 4-16.5 820
10 1004 1084 1250 1120 1250 200 60 4-16.5 870
11 1104 1184 1400 1240 1400 200 60 4-16.5 970
12 1204 1304 1500 1340 1600 200 60 4-16.5 970
13 1306 1406 1600 1440 1700 200 60 4-16.5 950
14 1406 1506 1700 1540 1800 200 60 4-16.5 1000

Note: the drilling in the base plate is an allowance within Φ-Φ; the fan assembly of this series normally cannot be opened on site. Special requirements can be made to order.

HTF-SII-L Vertical Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 A B C H H1 4-Φ L
6 603 663 800 690 800 200 40 4-16.5 580
7 703 783 950 820 950 200 40 4-16.5 830
8 804 884 1050 920 1050 200 40 4-16.5 870
9 904 984 1150 1020 1150 200 40 4-16.5 870
10 1004 1084 1250 1120 1250 200 60 4-16.5 970
11 1104 1184 1400 1240 1400 200 60 4-16.5 970
12 1204 1304 1500 1340 1600 200 60 4-16.5 1120
13 1306 1406 1600 1440 1700 200 60 4-16.5 1100
14 1406 1506 1700 1540 1800 200 60 4-16.5 1250

Note: the drilling in the base plate is an allowance within Φ-Φ; the fan assembly of this series normally cannot be opened on site. Special requirements can be made to order.

HTF-D-L Vertical Outline and Installation Dimensions (unit: mm)

Model Φ1 Φ2 A B C H H1 4-Φ L
5 503 563 700 590 700 200 40 4-14.5 490
5.5 553 613 750 640 750 200 40 4-14.5 490
6 603 663 800 690 800 200 40 4-16.5 490
6.5 653 733 850 740 850 200 40 4-16.5 580
7 703 783 950 820 950 200 40 4-16.5 670
8 804 884 1050 920 1050 200 40 4-16.5 670
9 904 984 1150 1020 1150 200 40 4-16.5 670
10 1004 1084 1250 1120 1250 200 60 4-16.5 670
11 1104 1184 1400 1240 1400 200 60 4-16.5 670
12 1204 1304 1500 1340 1600 200 60 4-16.5 870
13 1306 1406 1600 1440 1700 200 60 4-16.5 870
15 1506 1606 1800 1640 1900 200 60 4-16.5 1150

Note: the drilling in the base plate is an allowance within Φ-Φ; the fan assembly of this series normally cannot be opened on site. Special requirements can be made to order.

HTF Vertical Installation Foundation and Matching Outline

HTF Vertical Installation Foundation Drawing

HTF Vertical Installation Foundation Dimensions (unit: mm)

Model A B 4-Φ₂ H₁ C (hood) H₂ (hood) With anchor bolts
3.5 560 390 Φ13 50 660 200 4-M12×200
4 600 440 Φ13 50 860 200 4-M12×200
4.5 650 490 Φ13 50 860 235 4-M12×200
5 700 540 Φ15 50 1060 235 4-M12×200
5.5 750 590 Φ15 50 1060 235 4-M12×200
6 800 640 Φ15 60 1240 250 4-M12×200
6.5 850 690 Φ16.5 60 1240 265 4-M14×200
7 950 760 Φ16.5 60 1410 265 4-M14×200
8 1050 860 Φ16.5 70 1600 345 4-M14×200
9 1150 960 Φ19 70 1600 410 4-M14×200
10 1250 1060 Φ19 80 1800 410 4-M14×200
11 1400 1180 Φ19 80 1800 480 4-M16×250
12 1500 1280 Φ19 80 2040 480 4-M16×250
13 1600 1380 Φ19

Note: anchor bolts are supplied by the user.

HTF-X Series Fan Box Outline Drawing

HTF-X Series Fan Box Dimensions (unit: mm)

Model L W L1 W1 E H 4-Φd
3.5 770 650 735 720 360 713 4-Φ12
4 800 700 765 770 410 763 4-Φ12
4.5 850 750 815 820 460 813 4-Φ12
5 900 800 865 870 510 863 4-Φ12
5.5 925 850 890 920 560 913 4-Φ12
6 1000 900 965 970 610 963 4-Φ12
6.5 1025 950 990 1020 660 1013 4-Φ12
7 1145 1000 1110 1070 710 1063 4-Φ12
8 1190 1100 1150 1170 810 1163 4-Φ12
9 1265 1200 1245 1270 910 1263 4-Φ12
10 1470 1300 1430 1370 1010 1380 4-Φ14
11 1540 1500 1500 1570 1400×1450 1580 4-Φ14
12 1645 1600 1605 1670 1500×1550 1680 4-Φ14
13 1680 1700 1640 1770 1600×1650 1780 4-Φ14
14 1720 1800 1680 1870 1700×1750 1880 4-Φ14

HTF-BX Sound-insulated Axial Smoke Extract Fan — Structural Diagram

HTF-BX Sound-insulated Dimensions (D1/D2/D3, unit: mm)

Model D1 D2 D3 n-Φd
4 402 440 505 8
4.5 452 490 555 8
5 503 550 606 8
5.5 553 600 656 12
6 603 650 706 12
6.5 653 700 756 12
7 703 750 806 12
8 804 850 908 16
9 904 960 1008 16
10 1004 1060 1108 16
11 1105 1160 1210 20
12 1205 1260 1310 20
13 1306 1370 1412 20
14 1406 1470 1512 20

Note: the silencer is a separate component and is not included in the BX model; it must be stated when ordering. Silencer length Lx (mm): 600/900/1200/1500/2000, with corresponding attenuation (dBA): 4-6/6-8/7-11/9-13/11-15.

Product Photos

Custom builds available — contact our service team

HTF smoke extract fan — angled side view
HTF smoke extract fan — front impeller
HTF smoke extract fan — side view
HTF smoke extract fan — motor end view

Applications · Fire smoke extraction and ventilation

O

Office buildings

Key equipment in fire smoke extraction systems

S

Shopping malls

Large-space smoke extraction

B

Basements

Underground space smoke extraction

T

Tunnels

Tunnel smoke extraction

FAQ

Q: Where is an axial smoke extract fan suitable?

A: Widely used in the smoke extraction systems of office buildings, shopping malls, hospitals, hotels, residential buildings, basements and tunnels, and in large spaces that need high-airflow smoke exhaust and air change — an ideal unit for both smoke extraction and daily ventilation.

Q: Can the fan run continuously for a long time at 280 ℃?

A: Yes. A purpose-designed high-temperature motor drives the impeller directly and a built-in cooling system meets the high-temperature duty of smoke extract fans; long high-temperature smoke extraction stays stable and reliable, ensuring effective extraction in a fire.

Q: Is the fan noisy?

A: A moulded hub and curved blades with direct drive from an efficient motor give smooth running, low vibration and low noise — meeting the high airflow demand of smoke extraction while keeping noise low.

Q: Can airflow and pressure be customised?

A: Yes. Models are selected from the space volume, air-change rate and system resistance to fix the required airflow and pressure; units can also be built to customer-supplied dimensions, airflow and pressure for different smoke extraction and ventilation projects.

Q: Is the casing material durable? Are anti-corrosion and explosion-proof versions available?

A: The casing is thickened carbon steel with a painted finish — wear-resistant, corrosion-resistant, shock-proof and durable. Anti-corrosion and explosion-proof versions can also be built to match the conveyed medium and the working environment.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need a axial Smoke Extract Fan?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top