The DeLENG BT35-11 explosion-proof axial flow fan is built in Dezhou to Exd II BT4, with a steel casing, aluminium-alloy impeller, red guard mesh and bolted covers. It exhausts flammable and explosive gases in petrochemical plants, coal mines, tank farms and paint shops — 13 sizes from 2.8 to 11.2, four blade angles, wall or duct installation, custom builds accepted.

Explosion-proof Exd II BT4Steel casingLow noiseHigh airflowFactory direct
BT35-11 explosion-proof axial flow fan

Product introduction

The BT35-11 axial flow fan is the power unit of a ventilation system: it supplies, exhausts or circulates air and gives the system a steady airflow and pressure. The explosion-proof version uses an Exd II BT4 flameproof motor and terminal box, so the motor and wiring can work in areas where flammable and explosive gas may be present.

The unit runs smoothly and matches flexibly: airflow, pressure and mounting form can be selected to suit the system, and non-standard sizes, voltages and finishes are built to order. Impellers are aluminium alloy, dynamically balanced as a set; the casing is coated steel sheet with an EX marking, a safety guard mesh and bolted covers.

Service hotline: +86 534 2555668

Key features of the BT35-11 explosion-proof axial fan

Explosion-proof design · steel casing · low-noise running · high airflow

E

Explosion-proof design

Exd II BT4 flameproof rating for petrochemical plants, coal mines and other flammable and explosive areas.

S

Steel casing

Quality steel sheet with powder coating — corrosion and rust resistant, rigid and neat in appearance.

L

Low-noise running

Impellers are dynamically balanced as a set, so the unit runs smoothly with low noise and no disturbance to the workplace.

H

High airflow

Several blade angles are available, giving a wide airflow and pressure range to suit different ventilation duties.

Product details

Quality details you can see — built for your satisfaction

Explosion-proof EX marking

Explosion-proof EX marking

Flameproof motor and terminal box marked EX; the cover must not be opened while the unit is live.

Safety guard mesh

Safety guard mesh

A red steel-wire guard mesh on the impeller side stops foreign objects being drawn in and damaging the fan.

Fastening screws

Fastening screws

Impeller and guard mesh are held by bolted covers so the assembly stays stable and safe in service.

T35 / BT35 / BFT35 / FT35-11 series axial fan performance parameters

Complete parameter table · power supply 380 V/50 Hz

Model
No.
Impeller diameter
(mm)
Impeller speed
(r/min)
Blade angle
(°)
Airflow
(m³/h)
Total pressure
(Pa)
Motor power
(kW)
2.8 280 2900 15 1649 155 0.12
20 2167 172 0.18
25 2685 177 0.18
30 2921 190 0.25
35 3202 237 0.25
1450 15 826 39 0.025
20 1086 44 0.025
25 1346 45 0.025
30 1464 49 0.04
35 1605 61 0.04
3.15 315 2900 15 2339 196 0.18
20 3070 218 0.25
25 3810 224 0.37
30 4141 244 0.37
35 4545 300 0.55
1450 15 1169 49 0.025
20 1537 54 0.04
25 1905 56 0.04
30 2072 60 0.06
35 2273 75 0.09
3.55 355 2900 15 3367 246 0.37
20 4426 277 0.55
25 5484 284 0.55
30 5965 306 0.75
35 6542 380 1.1
1450 15 1680 62 0.04
20 2208 69 0.06
25 2737 71 0.09
30 2977 76 0.09
35 3265 95 0.12
4 400 2900 15 4806 316 0.55
20 6316 352 1.1
25 7826 361 1.1
30 8531 388 1.1
35 9336 483 1.5
1450 15 2406 79 0.09
20 3136 88 0.12
25 3920 90 0.12
30 4263 97 0.18
35 4678 121 0.25
15 3427 100 0.12
4.5 450 1450 20 4504 112 0.18
25 5881 115 0.25
30 6070 123 0.37
35 6658 153 0.37
15 4700 124 0.25
5 500 1450 20 6178 138 0.37
25 7655 141 0.37
30 8327 152 0.55
35 9133 189 0.75
960 15 3124 54 0.37
20 4129 60 0.37
25 5117 62 0.37
30 5566 66 0.37
35 6104 83 0.37
5.6 560 1450 15 6595 154 0.37
20 8667 172 0.55
25 10739 177 0.75
30 11682 190 1.1
35 12812 237 1.1
960 15 4362 68 0.37
20 5703 75 0.37
25 7101 77 0.37
30 7724 83 0.37
35 8471 103 0.37
6.3 630 1450 15 9393 196 0.75
20 12345 218 1.1
25 15297 224 1.5
30 16639 241 1.5
35 18250 300 2.2
960 15 6219 86 0.37
20 8173 96 0.37
25 10128 98 0.37
30 11016 106 0.75
35 12082 131 0.75
7.1 710 1450 15 13444 249 1.5
20 17670 277 2.2
25 21895 284 2.2
30 23815 306 3.0
35 26120 380 4.0
960 15 8902 110 0.75
20 11700 122 0.75
25 14498 125 0.75
30 15766 134 0.75
35 17296 167 1.1
8 800 1450 15 19235 316 2.2
20 25280 352 4.0
25 31325 361 4.0
30 34073 388 5.5
35 37070 483 7.5
960 15 12733 139 0.75
20 16733 154 1.1
25 20735 158 1.5
30 22556 170 1.5
35 24739 212 2.2
15 18132 175 1.5
9 900 960 20 23830 195 2.2
25 29529 200 3.0
30 32119 215 3.0
35 35227 268 4.0
15 24874 217 2.2
10 1000 960 20 32691 241 3.0
25 40508 247 4.0
30 44062 266 4.0
35 48326 331 7.5
15 34944 275 4.0
11.2 1120 960 20 45927 303 5.5
25 56909 310 7.5
30 61091 344 7.5
35 67892 415 11.0

Outline and installation dimensions

BT35-11 series axial fan — overall and installation dimensions (unit: mm)

BT35-11 explosion-proof axial fan outline and installation dimensions
Model D₁(mm) D₂(mm) D₃(mm) L(mm) Mounting holes n-φ1 Weight(kg)
2.8 283 320 346 258 4-φ8.5 9
3.15 318 355 381 282 6-φ8.5 11
3.55 358 395 422 327 6-φ8.5 17
4 404 450 478 350 6-φ10.5 19
4.5 454 500 528 354 6-φ10.5 20
5 504 560 588 364 8-φ10.5 28
5.6 564 620 649 404 8-φ12.5 39
6.3 634 690 719 474 10-φ12.5 55
7.1 715 770 800 494 10-φ12.5 65
8 805 860 891 579 12-φ12.5 88
9 905 970 1001 648 12-φ12.5 118
10 1006 1070 1103 753 12-φ12.5 148
11.2 1126 1190 1223 838 14-φ12.5 179

D1 / D2 / D3 / L are fan body dimensions; n-φ1 are flange mounting holes. Dimensions in mm, weight in kg.

Product photos

Source factory · real product shots · quality you can see

BT35-11 explosion-proof axial fan Casing, EX marking side
BT35-11 explosion-proof axial fan Impeller side with red guard mesh
BT35-11 explosion-proof axial fan Unit, three-quarter view

Applications

P

Petrochemical plants

Exhaust and air exchange in flammable and explosive gas areas, with flameproof motor and Ex wiring.

C

Coal mines and dust areas

Ventilation and dust removal in dusty duties; steel impeller and guard mesh keep foreign objects out.

T

Tank farms and fuel stations

Forced exhaust in tank areas and loading zones; explosion-proof rating Exd II BT4.

P

Painting and solvent workshops

Extraction of paint mist and solvent vapours, ducted straight to atmosphere if required.

FAQ

Q: What is the explosion-proof rating, and where can the fan be used?

A: The motor and wiring are Exd II BT4 flameproof, suitable for petrochemical plants, coal mines, tank farms, paint and solvent workshops and other areas where Group IIB, T4 flammable and explosive gases may be present. State the medium and the hazardous-area classification when ordering so the unit is configured to the right rating.

Q: How do model size, airflow and motor power correspond, and what is the range?

A: Sizes run from 2.8 to 11.2 (2.8, 3.15, 3.55, 4, 4.5, 5, 5.6, 6.3, 7.1, 8, 9, 10 and 11.2), each with five blade angles from 15° to 35°. Size 2.8 at 15° gives about 1,649 m³/h at 155 Pa on a 0.12 kW motor; size 11.2 at 35° gives about 67,892 m³/h at 415 Pa on 11 kW. Select the size and angle from the required air changes and duct resistance.

Q: What mounting options are there, and how do I choose between wall and duct?

A: Wall mounting, duct installation and workstation supply are all available. Wall mounting fixes the fan straight into a wall opening with a guard mesh and suits side-wall exhaust in workshops; duct installation bolts inlet and outlet flanges onto the fan and puts it in line in the ducting, for long exhaust runs or where air must be discharged at one point. A fixed bracket can also be used for spot cooling.

Q: What is the casing made of, and what maintenance does it need?

A: The casing is coated quality steel sheet, corrosion and rust resistant. The impeller is dynamically balanced and runs smoothly; the casing carries an EX marking, a safety guard mesh and bolted covers. Routine work is limited to clearing dust from the impeller and guard mesh and checking fasteners and terminal seals — the flameproof terminal box must never be opened while the unit is live.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need BT35-11 Explosion-proof Axial Fan?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668