Home›Products ›Ceiling-mounted AHU ›DeLENG Ceiling-mounted Fresh-air AHU (Jet / Standard)
DeLENG · factory direct supply

DeLENG Ceiling-mounted Fresh-air AHU (Jet / Standard)

Ceiling-mounted air handling units are suspended in the ceiling void with cooling coil, fan and filter sections configured to the project cooling load and external static pressure.

Airflow 1,500-12,000 m³/hThrow distance 16-28 mJet / standard versionsCoil 4 / 6 / 8 rows
DeLENG Ceiling-mounted Fresh-air AHU (Jet / Standard)

DeLENG Ceiling-mounted Fresh-air AHU (Jet / Standard)

Product introduction

The DeLENG KTDS(X) series ceiling-mounted fresh-air air handling unit consists of a mixing/filter section, a coil section and a fan section. It filters outdoor fresh air, cools and dehumidifies it (or heats it) and then delivers it into the room. The unit is suspended at the top of tall spaces or high on a side wall, so no long duct run is required, saving building space and duct cost. Two outlet versions are available: the jet version is fitted with adjustable spherical nozzles that discharge at 8–12 m/s with air entrainment and throw 16–28 m; the standard version uses louvre grilles for even short-distance supply at normal ceiling heights.

Airflow covers 1,500–12,000 m³/h, with cooling coils in 4-row, 6-row and 8-row versions and external-rotor direct-drive centrifugal fans (1–3 fans, 0.32–1.1 kW each), noise 58–69 dB(A). The one-piece galvanised steel frame is acid and corrosion resistant and runs smoothly. A primary filter, heating coil and intelligent control are available as options, and non-standard units can be customised for the project.

Service hotline: 0534-2555668

Key features · Ceiling-mounted Fresh-air AHU

Two versions

Jet version for long throw, standard version for short-distance supply

Multi-function control

Cooling, heating, humidifying and dehumidifying, adjustable on demand

High efficiency

Energy-saving design keeps comfort while cutting energy use

Intelligent control

Adjusts automatically to indoor conditions to keep air quality optimal

Selling points

Ceiling fresh-air AHU high-efficiency filter
Ceiling fresh-air AHU copper-tube coil
Ceiling fresh-air AHU centrifugal fan

Technical parameters

Model Air volume (m³/h) Throw distance (m) Fan Weight (kg) Noise dB(A)
Type Qty Power (kW) 4-row 6-row 8-row
KTDS(X)-1.5 1500 ~16 External-rotor direct-drive centrifugal fan 1 0.32 68 71 74 58
KTDS(X)-2 2000 ~18 1 0.37 78 82 86 59
KTDS(X)-2.5 2500 ~20 1 0.45 81 86 91 59
KTDS(X)-3 3000 ~21 1 0.55 93 99 105 60
KTDS(X)-4 4000 ~18 2 0.37*2 117 124 132 61
KTDS(X)-5 5000 ~20 2 0.45*2 130 139 148 62
KTDS(X)-6 6000 ~21 2 0.55*2 143 154 164 63
KTDS(X)-7 7000 ~20 2 0.75*2 165 178 191 63
KTDS(X)-8 8000 ~21 3 0.55*3 169 183 198 64
KTDS(X)-9 9000 ~21 3 0.55*3 205 223 255 67
KTDS(X)-10 10000 ~26 3 1.1*3 224 240 256 68
KTDS(X)-12 12000 ~28 3 1.1*3 247 266 284 69

Cooling capacity (fresh-air condition): entering air DB 35℃ / WB 27.5℃, chilled water 7℃, ΔT 5℃

Model Air volume (m³/h) Cooling capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTDX-1.5 1500 19.4 21.5 22.2 3.67 4.07 4.2 12.2 18.1 21.2
KTDX-2 2000 27.2 33.2 38.2 5.15 6.29 7.23 12.9 21.4 23.4
KTDX-2.5 2500 33.8 40.9 47.6 6.4 7.74 9.01 13.6 22.5 25.5
KTDX-3 3000 40.6 49 57.3 7.69 9.27 10.84 14.5 23.4 29.1
KTDX-4 4000 52.3 64.9 85 9.9 12.28 16.08 16.5 24.3 33.6
KTDX-5 5000 65.7 81.4 104 12.43 15.4 19.68 17.6 24.4 36.1
KTDX-6 6000 80.8 97.7 119 15.29 18.49 22.52 18.7 29.8 43.5
KTDX-7 7000 98.4 125.6 156.3 18.62 23.76 29.57 19.2 30.6 41.9
KTDX-8 8000 101.6 139.8 176.8 19.22 26.45 33.45 19.1 30.2 43.5
KTDX-9 9000 115.2 154.5 194.3 21.8 29.23 36.76 19.6 30.9 41.7
KTDX-10 10000 126.2 179.5 219 23.88 33.96 41.43 20.3 32.1 43.2
KTDX-12 12000 169 210.1 257.5 31.97 39.75 48.72 21.4 30.9 43.5
KTDX-13.5 13500 190.3 222.6 275.4 36 42.11 52.1 21.9 32.7 45.3
KTDX-15 15000 211.4 257.4 324.8 39.99 48.7 61.45 22.3 33.3 47.3

Heating capacity (fresh-air condition): entering air DB 7℃, hot water 60℃

Model Air volume (m³/h) Heating capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTDX-1.5 1500 16.6 21.8 26.5 3.15 4.13 5.02 12.2 18.1 21.2
KTDX-2 2000 21.4 29.5 38 4.05 5.59 7.19 12.9 21.4 23.4
KTDX-2.5 2500 27.2 36.9 48.1 5.15 6.99 9.1 13.6 22.5 25.5
KTDX-3 3000 32.8 45.1 58.7 6.21 8.54 11.11 14.5 23.4 29.1
KTDX-4 4000 44 68 80.8 8.33 12.87 15.29 16.5 24.3 33.6
KTDX-5 5000 53.2 73 89.5 10.07 13.81 16.94 17.6 24.4 36.1
KTDX-6 6000 63.5 88.2 98.3 12.02 16.69 18.6 18.7 29.8 43.5
KTDX-7 7000 77.8 104.6 127.6 14.72 19.79 24.14 19.2 30.6 41.9
KTDX-8 8000 94.6 116 143.3 17.9 21.95 27.11 19.1 30.2 43.5
KTDX-9 9000 101.2 129.3 153.3 19.15 24.46 29 19.6 30.9 41.7
KTDX-10 10000 112.3 142.3 163.3 21.25 26.92 30.9 20.3 32.1 43.2
KTDX-12 12000 137.4 170.6 199.5 26 32.28 37.74 21.4 30.9 43.5
KTDX-13.5 13500 152.9 190.5 220.6 28.93 36.04 41.74 21.9 32.7 45.3
KTDX-15 15000 170.9 212.6 248 32.33 40.22 46.92 22.3 33.3 47.3

Cooling capacity (return-air condition): entering air DB 27℃ / WB 19.5℃, chilled water 7℃, ΔT 5℃

Model Air volume (m³/h) Cooling capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTD-1.5 1500 8.4 10 11.3 1.59 1.9 2.14 6.8 10.1 11.8
KTD-2 2000 11.2 15.2 19.5 2.12 2.88 3.69 7.2 11.9 13
KTD-2.5 2500 13.9 18.9 24.6 2.63 3.58 4.66 7.6 12.5 14.2
KTD-3 3000 16.8 22.8 29.5 3.18 4.32 5.59 8.1 12.8 16.2
KTD-4 4000 22.1 30.2 39.3 4.19 5.72 7.44 9.2 13.5 18.7
KTD-5 5000 27.6 37.7 49.1 5.23 7.14 9.29 9.8 13.6 20.1
KTD-6 6000 33.2 45.3 60.6 6.29 8.57 11.47 10.4 16.6 24.2
KTD-7 7000 43.6 58.3 71.4 8.25 11.03 13.51 10.6 16.7 23.3
KTD-8 8000 49.6 66.4 82.6 9.39 12.57 15.63 10.6 16.7 24.2
KTD-9 9000 53.2 72.6 87.2 10.07 13.74 16.5 10.9 17.2 23.2
KTD-10 10000 57.6 78.7 93.9 10.9 14.89 17.77 11.3 17.8 23.9
KTD-12 12000 69.6 88.1 112.5 13.17 16.67 21.29 11.9 17.2 24.2
KTD-13.5 13500 78.3 99 126.4 14.82 18.73 23.92 12.2 18.2 25.2
KTD-15 15000 87 110 140.5 16.46 20.81 26.58 12.4 18.5 26.3

Heating capacity (return-air condition): entering air DB 15℃, hot water 60℃

Model Air volume (m³/h) Heating capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTD-1.5 1500 14.2 18.6 22.8 2.69 3.52 4.32 6.8 10.1 11.8
KTD-2 2000 18.3 25.3 32.5 3.47 4.79 6.15 7.2 11.9 13
KTD-2.5 2500 23.2 31.5 41.1 4.39 5.96 7.78 7.6 12.5 14.2
KTD-3 3000 28.1 38.5 50.2 5.32 7.29 9.5 8.1 12.8 16.2
KTD-4 4000 37.6 51.8 68.9 7.12 9.8 13.04 9.2 13.5 18.7
KTD-5 5000 45.6 62.4 79.1 8.63 11.81 14.97 9.8 13.6 20.1
KTD-6 6000 54.3 75.4 84 10.28 14.27 15.89 10.4 16.6 24.2
KTD-7 7000 66.3 85.8 106.1 12.55 16.24 20.08 10.6 16.7 23.3
KTD-8 8000 80.8 96.1 119.5 15.29 18.18 22.61 10.6 16.7 24.2
KTD-9 9000 88.3 102.6 127.6 16.71 19.41 24.14 10.9 17.2 23.2
KTD-10 10000 96 110.6 139.6 18.16 20.93 26.41 11.3 17.8 23.9
KTD-12 12000 117.5 145.9 170.5 22.23 27.06 32.26 11.9 17.2 24.2
KTD-13.5 13500 130.7 162.8 188.4 24.73 30.8 35.64 12.2 18.2 25.2
KTD-15 15000 145.8 181.7 211.9 27.59 34.38 40.09 12.4 18.5 26.3

Dimensions (unit: mm)

Model KTDS(X)-1.5 KTDS(X)-2 KTDS(X)-2.5 KTDS(X)-3 KTDS(X)-4 KTDS(X)-5 KTDS(X)-6 KTDS(X)-7 KTDS(X)-8 KTDS(X)-9 KTDS(X)-10 KTDS(X)-12
L 1103 1103 1103 1103 1103 1103 1103 1103 1103 1103 1300 1300
W 700 840 980 1120 1400 1680 1960 1960 1960 1960 2080 2180
H 500 550 550 550 550 550 550 580 620 680 680 740
E 4-row: E=83 mm; 6-row: E=138 mm; 8-row: E=193 mm
F 310 310 310 310 310 310 310 440 475 475 540 600
D(in) 1.2 1.2 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2
Nozzle specification φ315 φ400 φ400 φ400 φ400 φ400 φ400 φ400 φ400 φ400 φ400 φ500
Nozzle quantity 1 1 1 1 2 2 2 2 3 3 3 3

Dimension drawing

Applications

H

Hotel

Fresh air and comfortable supply for guest rooms

S

Shopping mall

Long-throw air supply for large spaces

F

Factory workshop

Industrial ventilation and clean-air treatment

H

Hospital

Medical purification and fresh-air systems

FAQ

Q: What is the difference between the jet version and the standard version?

A: The jet version has adjustable spherical nozzles; the air leaves at 8–12 m/s, entrains the surrounding air and reaches 16–28 m, which suits tall spaces such as workshops and arenas. The standard version has louvre grilles for even short-distance supply and suits normal ceiling heights such as hotels and offices.

Q: How are the airflow and throw distance selected?

A: The KTDS(X) series covers 1,500–12,000 m³/h with a throw of 16–28 m, models from -1.5 to -12; select by room volume, air-change rate and supply distance. Fans are external-rotor direct-drive centrifugal units, 1–3 per unit at 0.32–1.1 kW each, with noise 58–69 dB(A).

Q: How are the coil rows and nozzles configured?

A: Coils are available in 4-row, 6-row and 8-row versions — more rows give more heat transfer. The number of jet nozzles (1–3) is set by airflow and coverage area, and the nozzle angle can be adjusted on site. The unit is suspended at the ceiling top or high on a side wall; no long duct run is needed.

Q: Can the unit be customised, and what is needed for an order?

A: Airflow, external static pressure, coil rows, jet or standard outlet, filter section and heating section can all be customised for the project. Provide the required airflow, cooling/heating duty, installation position and ceiling dimensions for selection and quotation.

Selection and quotation: +86 534 2555668  |  WeChat: +86 534 2555668  |  Email: sales@deleng.com

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need Ceiling-mounted Fresh-air AHU?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top