Primary / medium / high-efficiency three-stage filtration covering 1500-50000 m³/h, removing smoke, dust and PM2.5, cabinet type installation.

The DeLENG air purification box filter uses a three-stage pre-filter + medium-efficiency + HEPA design that effectively removes smoke, particulate matter, pollen, PM2.5 and micro-organisms from the air. The casing can be galvanised sheet steel, colour steel sheet or polyurethane panel; the unit is cabinet-type and floor-standing, and can be used together with fan coil units, air handling units and fresh-air systems.
Two series are available — pre + medium efficiency and pre + medium + high efficiency — covering an airflow of 1,500–50,000 m³/h. They suit hospitals, electronics plants, food workshops, laboratories, office buildings and shopping malls where air quality requirements apply.
Service hotline: 0534-2555668
Pre-filter + medium + HEPA, layer by layer
High-efficiency stage captures fine particles
Galvanised / colour steel / polyurethane panel
Floor-standing, easy to service
| Filter stage | Efficiency | Target pollutants | Initial resistance (Pa) | Final resistance (Pa) | Replacement interval |
|---|---|---|---|---|---|
| Pre-filter G4 | G4 | Large dust, hair, pollen | ≤50 | 100 | 3–6 months |
| Medium-efficiency F8 | F8 | PM10, fine dust | ≤80 | 160 | 6–12 months |
| High-efficiency H13 | H13 | PM2.5, 0.3 µm particles | ≤120 | 250 | 1–2 years |
| Model | Airflow (m³/h) | Resistance (Pa) | Inlet/outlet A×B (mm) | Overall size L×W×H (mm) | Filter size (mm) |
|---|---|---|---|---|---|
| DLJHX-15D | 1500 | 350 | 570×330 | 1000×660×420 | 592×287×1 |
| DLJHX-30D | 2500 | 350 | 570×530 | 1000×660×620 | 592×490×1 |
| DLJHX-35D | 3500 | 350 | 570×635 | 1000×660×725 | 592×592×1 |
| DLJHX-40D | 4000 | 350 | 760×635 | 1000×850×725 | 592×592×1+592×287×1 |
| DLJHX-65D | 6000 | 350 | 960×635 | 1000×1050×725 | 592×487×2 |
| DLJHX-80D | 8000 | 350 | 1160×635 | 1000×1290×725 | 592×592×2 |
| DLJHX-90D | 9000 | 350 | 1160×760 | 2000×1290×890 | 592×490×2+592×287×2 |
| DLJHX-120D | 12000 | 350 | 1160×960 | 2000×1290×1090 | 592×490×4 |
| DLJHX-150D | 15000 | 350 | 1160×1160 | 2000×1290×1290 | 592×592×4 |
| DLJHX-200D | 20000 | 350 | 1470×1100 | 2000×1600×1290 | 592×592×4+592×287×2 |
| DLJHX-250D | 25000 | 350 | 1760×1460 | 2000×1900×1600 | 592×592×6+592×287×3 |
| DLJHX-300D | 30000 | 350 | 1760×1760 | 2000×1900×1800 | 592×592×6+592×490×3 |
| DLJHX-350D | 35000 | 350 | 2370×1760 | 2000×2510×1800 | 592×592×8+592×490×4 |
| DLJHX-400D | 40000 | 350 | 2370×1860 | 2000×2510×1900 | 592×592×12 |
| DLJHX-450D | 45000 | 350 | 2370×2080 | 2000×2510×2210 | 592×592×12+592×287×4 |
| DLJHX-500D | 50000 | 350 | 2980×1860 | 2000×2510×2410 | 592×592×12+592×490×4 |
Filter class: panel pre-filter G4 + bag medium-efficiency F7 + sub-HEPA H11

Different combinations can be made to customer requirements

| Model | Airflow (m³/h) | Filter stages | Efficiency | Application |
|---|---|---|---|---|
| Pre+Medium 1500 | 1500 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 2500 | 2500 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 3500 | 3500 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 4000 | 4000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 5000 | 5000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 7000 | 7000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 8000 | 8000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 12000 | 12000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 15000 | 15000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 20000 | 20000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 25000 | 25000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 30000 | 30000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 35000 | 35000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 40000 | 40000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 45000 | 45000 | G4+F8 | ≥90% | General dust & odour removal |
| Pre+Medium 50000 | 50000 | G4+F8 | ≥90% | General dust & odour removal |
| Model | Airflow (m³/h) | Filter stages | Efficiency | Application |
|---|---|---|---|---|
| Pre+Medium+HEPA 1500 | 1500 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 2500 | 2500 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 3500 | 3500 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 4000 | 4000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 6000 | 6000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 8000 | 8000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 9000 | 9000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 12000 | 12000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 15000 | 15000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 20000 | 20000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 25000 | 25000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 30000 | 30000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 35000 | 35000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 40000 | 40000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 45000 | 45000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |
| Pre+Medium+HEPA 50000 | 50000 | G4+F8+H13 | ≥99.95% | Clean room / hospital |

Air inlet → high-efficiency filter box → fan → flexible connector → air duct → air outlet, suspended on expansion rods
Clean wards and GMP rooms, with the H13 stage
Dust and odour removal to protect product quality
Particle control for a stable testing environment
Comfortable, filtered air supply
A: Pre + medium is pre-filter G4 plus medium F8 in two stages, for general dust and odour removal. The pre + medium + HEPA series adds an H13 HEPA stage that captures PM2.5 and 0.3 µm particles, for places with high cleanliness requirements. Without the HEPA stage the casing length can be shortened by 350 mm.
A: Replace by initial/final resistance: pre-filter G4 has initial resistance ≤50 Pa and final 100 Pa, usually 3–6 months; medium F8 is ≤80 Pa initial and 160 Pa final, 6–12 months; HEPA H13 is ≤120 Pa initial and 250 Pa final, 1–2 years. Replace when the resistance approaches the final value or the pressure differential becomes abnormal.
A: Panel pre-filter 50 mm, panel activated carbon 50 mm, bag medium-efficiency 250 mm, HEPA filter 300 mm. Casing length is the total of all stages; without the HEPA stage it can be 350 mm shorter, and the bag depth of the bag medium-efficiency filter can be customised.
A: Yes. The purification box can be combined with heat-recovery ventilators, air handling units and fan coil units, with airflow from 1,500 to 50,000 m³/h and connection sizes made to site dimensions. The casing material can be galvanised sheet steel, colour steel sheet or polyurethane panel.
Selection and quotation: +86 534 2555668 | WeChat: +86 534 2555668 | Email: sales@deleng.com

Product display
View details →

Product display
View details →

Product display
View details →

Product display
View details →
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.