Home›Products ›Ceiling-mounted AHU ›Ceiling-mounted Air Handling Unit
DeLENG · factory direct supply

Ceiling-mounted Air Handling Unit

Ceiling-mounted air handling units are suspended in the ceiling void with cooling coil, fan and filter sections configured to the project cooling load and external static pressure.

Air handling unitAirflow 1,500-15,000 m³/hCooling · heating · humidifyingIntelligent controlIndustrial + commercial
Ceiling-mounted Air Handling Unit

Ceiling-mounted Air Handling Unit

Product introduction

The unit consists of a mixing and filter section, a cooling coil section and a fan section, with optional humidification, purification and dust-removal sections. Chilled water exchanges heat with the air through the coil, and the fan delivers the conditioned air. The frame is formed from galvanised steel sheet in one piece and is resistant to acid, strong alkali and corrosion, so it suits long-term use in harsh environments.

Suitable for air purification systems in clean workshops, and widely used in hotels, shopping malls, airports, hospitals, factories and research institutes. Three installation variants are available: air-cooled direct-expansion, air-cooled heat-pump and air-cooled 100% fresh-air.

Streamlined fan wheel and advanced duct design keep operating noise as low as 27 dB. All-copper motor and a high-density slide-out filter that is easy to clean. Non-standard customisation is supported — airflow, power and dimensions can be configured to project requirements. Call 0534-2555668.

Key features · Why choose the Ceiling-mounted Air Handling Unit

Wide series coverage

Vertical, horizontal and ceiling-mounted series covering an airflow range of 1,500 to 15,000 m³/h.

Multi-function control

Cooling, heating, humidification and dehumidification, adjustable to the indoor environment as required.

Wide applicability

Suits commercial spaces as well as industrial fields such as electronics, chemicals, medical, pharmaceutical and food.

High efficiency & energy saving

Advanced energy-saving technology keeps comfort while minimising energy consumption.

Selling points

Ceiling-mounted AHU high-density filter
Ceiling-mounted AHU premium heat exchanger
Ceiling-mounted AHU external-rotor centrifugal fan

Technical parameters

Model Air volume (m³/h) External static pressure (Pa) Fan Weight (kg) Noise dB(A)
4-row 6-row 8-row Type Power Qty 4-row 6-row 8-row
KTD(X)-1.5 1500 260 200 150 External-rotor direct-drive centrifugal fan 0.32 1 66 69 72 58
KTD(X)-2 2000 258 193 150 0.37 1 77 81 85 59
KTD(X)-2.5 2500 258 200 150 0.45 1 80 84 89 59
KTD(X)-3 3000 246 198 145 0.55 1 92 98 103 60
KTD(X)-4 4000 258 193 150 0.37*2 2 116 124 131 61
KTD(X)-5 5000 258 200 150 0.45*2 2 129 138 147 62
KTD(X)-6 6000 246 198 145 0.55*2 2 142 153 164 63
KTD(X)-7 7000 280 240 180 0.75*2 2 166 178 190 63
KTD(X)-8 8000 350 305 258 1.1*2 2 169 183 196 64
KTD(X)-9 9000 350 305 258 1.5*2 2 200 219 223 66
KTD(X)-10 10000 402 355 308 1.5*2 2 225 241 257 68
KTD(X)-12 12000 460 403 364 1.8*2 2 249 267 286 69
KTD(X)-13.5 13500 460 410 364 2.2*2 2 288 308 328 72
KTD(X)-15 15000 510 446 400 3.0*2 2 295 317 338 73

Cooling capacity (fresh-air condition): entering air DB 35℃ / WB 27.5℃, chilled water 7℃, ΔT 5℃

Model Air volume (m³/h) Cooling capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTDX-1.5 1500 19.4 21.5 22.2 3.67 4.07 4.2 12.2 18.1 21.2
KTDX-2 2000 27.2 33.2 38.2 5.15 6.29 7.23 12.9 21.4 23.4
KTDX-2.5 2500 33.8 40.9 47.6 6.4 7.74 9.01 13.6 22.5 25.5
KTDX-3 3000 40.6 49 57.3 7.69 9.27 10.84 14.5 23.4 29.1
KTDX-4 4000 52.3 64.9 85 9.9 12.28 16.08 16.5 24.3 33.6
KTDX-5 5000 65.7 81.4 104 12.43 15.4 19.68 17.6 24.4 36.1
KTDX-6 6000 80.8 97.7 119 15.29 18.49 22.52 18.7 29.8 43.5
KTDX-7 7000 98.4 125.6 156.3 18.62 23.76 29.57 19.2 30.6 41.9
KTDX-8 8000 101.6 139.8 176.8 19.22 26.45 33.45 19.1 30.2 43.5
KTDX-9 9000 115.2 154.5 194.3 21.8 29.23 36.76 19.6 30.9 41.7
KTDX-10 10000 126.2 179.5 219 23.88 33.96 41.43 20.3 32.1 43.2
KTDX-12 12000 169 210.1 257.5 31.97 39.75 48.72 21.4 30.9 43.5
KTDX-13.5 13500 190.3 222.6 275.4 36 42.11 52.1 21.9 32.7 45.3
KTDX-15 15000 211.4 257.4 324.8 39.99 48.7 61.45 22.3 33.3 47.3

Heating capacity (fresh-air condition): entering air DB 7℃, hot water 60℃

Model Air volume (m³/h) Heating capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTDX-1.5 1500 16.6 21.8 26.5 3.15 4.13 5.02 12.2 18.1 21.2
KTDX-2 2000 21.4 29.5 38 4.05 5.59 7.19 12.9 21.4 23.4
KTDX-2.5 2500 27.2 36.9 48.1 5.15 6.99 9.1 13.6 22.5 25.5
KTDX-3 3000 32.8 45.1 58.7 6.21 8.54 11.11 14.5 23.4 29.1
KTDX-4 4000 44 68 80.8 8.33 12.87 15.29 16.5 24.3 33.6
KTDX-5 5000 53.2 73 89.5 10.07 13.81 16.94 17.6 24.4 36.1
KTDX-6 6000 63.5 88.2 98.3 12.02 16.69 18.6 18.7 29.8 43.5
KTDX-7 7000 77.8 104.6 127.6 14.72 19.79 24.14 19.2 30.6 41.9
KTDX-8 8000 94.6 116 143.3 17.9 21.95 27.11 19.1 30.2 43.5
KTDX-9 9000 101.2 129.3 153.3 19.15 24.46 29 19.6 30.9 41.7
KTDX-10 10000 112.3 142.3 163.3 21.25 26.92 30.9 20.3 32.1 43.2
KTDX-12 12000 137.4 170.6 199.5 26 32.28 37.74 21.4 30.9 43.5
KTDX-13.5 13500 152.9 190.5 220.6 28.93 36.04 41.74 21.9 32.7 45.3
KTDX-15 15000 170.9 212.6 248 32.33 40.22 46.92 22.3 33.3 47.3

Cooling capacity (return-air condition): entering air DB 27℃ / WB 19.5℃, chilled water 7℃, ΔT 5℃

Model Air volume (m³/h) Cooling capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTD-1.5 1500 8.4 10 11.3 1.59 1.9 2.14 6.8 10.1 11.8
KTD-2 2000 11.2 15.2 19.5 2.12 2.88 3.69 7.2 11.9 13
KTD-2.5 2500 13.9 18.9 24.6 2.63 3.58 4.66 7.6 12.5 14.2
KTD-3 3000 16.8 22.8 29.5 3.18 4.32 5.59 8.1 12.8 16.2
KTD-4 4000 22.1 30.2 39.3 4.19 5.72 7.44 9.2 13.5 18.7
KTD-5 5000 27.6 37.7 49.1 5.23 7.14 9.29 9.8 13.6 20.1
KTD-6 6000 33.2 45.3 60.6 6.29 8.57 11.47 10.4 16.6 24.2
KTD-7 7000 43.6 58.3 71.4 8.25 11.03 13.51 10.6 16.7 23.3
KTD-8 8000 49.6 66.4 82.6 9.39 12.57 15.63 10.6 16.7 24.2
KTD-9 9000 53.2 72.6 87.2 10.07 13.74 16.5 10.9 17.2 23.2
KTD-10 10000 57.6 78.7 93.9 10.9 14.89 17.77 11.3 17.8 23.9
KTD-12 12000 69.6 88.1 112.5 13.17 16.67 21.29 11.9 17.2 24.2
KTD-13.5 13500 78.3 99 126.4 14.82 18.73 23.92 12.2 18.2 25.2
KTD-15 15000 87 110 140.5 16.46 20.81 26.58 12.4 18.5 26.3

Heating capacity (return-air condition): entering air DB 15℃, hot water 60℃

Model Air volume (m³/h) Heating capacity (kW) Water flow (m³/h) Water resistance (kPa)
4-row 6-row 8-row 4-row 6-row 8-row 4-row 6-row 8-row
KTD-1.5 1500 14.2 18.6 22.8 2.69 3.52 4.32 6.8 10.1 11.8
KTD-2 2000 18.3 25.3 32.5 3.47 4.79 6.15 7.2 11.9 13
KTD-2.5 2500 23.2 31.5 41.1 4.39 5.96 7.78 7.6 12.5 14.2
KTD-3 3000 28.1 38.5 50.2 5.32 7.29 9.5 8.1 12.8 16.2
KTD-4 4000 37.6 51.8 68.9 7.12 9.8 13.04 9.2 13.5 18.7
KTD-5 5000 45.6 62.4 79.1 8.63 11.81 14.97 9.8 13.6 20.1
KTD-6 6000 54.3 75.4 84 10.28 14.27 15.89 10.4 16.6 24.2
KTD-7 7000 66.3 85.8 106.1 12.55 16.24 20.08 10.6 16.7 23.3
KTD-8 8000 80.8 96.1 119.5 15.29 18.18 22.61 10.6 16.7 24.2
KTD-9 9000 88.3 102.6 127.6 16.71 19.41 24.14 10.9 17.2 23.2
KTD-10 10000 96 110.6 139.6 18.16 20.93 26.41 11.3 17.8 23.9
KTD-12 12000 117.5 145.9 170.5 22.23 27.06 32.26 11.9 17.2 24.2
KTD-13.5 13500 130.7 162.8 188.4 24.73 30.8 35.64 12.2 18.2 25.2
KTD-15 15000 145.8 181.7 211.9 27.59 34.38 40.09 12.4 18.5 26.3

Dimensions (unit: mm)

Model KTDX-1.5 KTDX-2 KTDX-2.5 KTDX-3 KTDX-4 KTDX-5 KTDX-6 KTDX-7 KTDX-8 KTDX-9 KTDX-10 KTDX-12 KTDX-13.5 KTDX-15
L 1103 1103 1103 1103 1103 1103 1103 1103 1103 1103 1300 1300 1300 1300
W 700 840 980 1120 1400 1680 1960 1960 1960 1960 2080 2180 2280 2340
H 500 500 500 500 500 500 500 580 620 680 680 740 780 810
F 310 310 310 310 310 310 310 440 475 475 540 600 630 665
m 320 320 400 400 320 400 400 400 500 500 500 500 500 500
n 200 200 200 250 200 200 250 250 250 320 400 400 400 400
N 200 200 200 250 200 700 760 760 820 820 820 900 900 1000
D(in) 1.2 1.2 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 2
E dimension: 4-row E=83 mm, 6-row E=138 mm, 8-row E=193 mm

Dimension drawing

Applications

Hotel

Comfort air handling

Shopping mall

Comfortable commercial environment

Office building

Intelligent control, constant temperature

Factory

Clean industrial air treatment

FAQ

Q: Is the air handling unit a chilled-water system or a DX (refrigerant) system?

A: DeLENG air handling units are chilled-water systems connected to a chiller or boiler, and provide both cooling and heating.

Q: Can the airflow be customised?

A: Yes. Any airflow between 1,500 and 15,000 m³/h can be customised to the project.

Q: What is the warranty period?

A: Three years on the complete unit, shipped nationwide from our factory in Dezhou, Shandong.

Selection and quotation: +86 534 2555668  |  WeChat: +86 534 2555668  |  Email: sales@deleng.com

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need a ceiling-mounted Air Handling Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top