DeLENG DWT series roof fans cover three types — axial, centrifugal and motorless turbine exhaust — for roof ventilation and smoke exhaust of plants, warehouses and basement garages. FRP housings resist corrosion and rain, and explosion-proof motors are available for hazardous atmospheres.

DeLENG DWT series roof fans are built for roof ventilation of industrial and civil buildings, in three versions: axial (DWT-I / V) for medium-low pressure and high airflow; centrifugal (DWT-II / III) for low airflow at higher pressure; and the motorless turbine exhaust fan (DWT-IV), driven by the pressure difference between indoors and outdoors with no external power supply.
The housing is moulded from high-grade FRP — sturdy, corrosion and ageing resistant, weatherproof, and suitable for long-term outdoor use. Copper-wire motors give low energy consumption, high efficiency, low vibration and reliable running. Explosion-proof motors, silencers and other accessories can be specified to suit the project.
DWT-II / III centrifugal impellers deliver high pressure at low airflow, overcoming long duct resistance — ideal for ducted roof exhaust.
Moulded FRP hood and housing: corrosion and ageing resistant, weatherproof, and undistorted after years of sun and rain outdoors.
Explosion-proof motors can be fitted for flammable gas exhaust in chemical, coating and other plants with explosion-proof requirements.
Triangular mechanical fixing cuts motor vibration and noise, so the roof installation runs steady without shaking.
Three core components, quality you can see
| Model | Speed (r/min) | Total pressure (Pa) | Air volume (m³/h) | Power (kW) | Noise (dB) | Weight (kg) |
|---|---|---|---|---|---|---|
| 3 | 1450 | 220 | 878 | 0.75 | 57 | 88 |
| 210 | 925 | |||||
| 188 | 1059 | |||||
| 167 | 1130 | |||||
| 122 | 1253 | |||||
| 3.5 | 1450 | 299 | 1395 | 1.1 | 59 | 95 |
| 285 | 1470 | |||||
| 256 | 1682 | |||||
| 227 | 1794 | |||||
| 166 | 1990 | |||||
| 4 | 1450 | 412 | 1887 | 1.1 | 62 | 115 |
| 391 | 2083 | |||||
| 372 | 2194 | |||||
| 334 | 2510 | |||||
| 298 | 2677 | |||||
| 4.5 | 1450 | 495 | 2966 | 1.1 | 63 | 154 |
| 471 | 3124 | |||||
| 423 | 3574 | |||||
| 376 | 3812 | |||||
| 231 | 4514 | |||||
| 5 | 1450 | 615 | 4068 | 2.2 | 64 | 195 |
| 582 | 4285 | |||||
| 522 | 4903 | |||||
| 485 | 5438 | |||||
| 378 | 6113 | |||||
| 6 | 960 | 385 | 5024 | 1.5 | 65 | 234 |
| 367 | 5512 | |||||
| 330 | 6120 | |||||
| 293 | 6782 | |||||
| 223 | 7338 | |||||
| 7 | 960 | 548 | 8015 | 3.0 | 68 | 292 |
| 499 | 8804 | |||||
| 488 | 9827 | |||||
| 398 | 10836 | |||||
| 371 | 11925 | |||||
| 8 | 960 | 721 | 12563 | 5.5 | 70 | 374 |
| 686 | 13565 | |||||
| 654 | 14157 | |||||
| 587 | 15824 | |||||
| 521 | 16708 | |||||
| 10 | 720 | 1072 | 22150 | 11 | 72 | 396 |
| 1020 | 23298 | |||||
| 916 | 26573 | |||||
| 813 | 28395 | |||||
| 702 | 31436 |

| Model | φA | B | C | D | E | φF | H | n×M(d)×L |
|---|---|---|---|---|---|---|---|---|
| 3 | φ690 | 430 | 80 | 322 | 436 | φ300 | 716 | 4×M8×80 |
| 3.5 | φ805 | 480 | 80 | 338 | 418 | φ350 | 758 | 4×M8×80 |
| 4 | φ920 | 520 | 80 | 350 | 508 | φ400 | 803 | 4×M8×80 |
| 4.5 | φ1035 | 570 | 80 | 390 | 560 | φ450 | 815 | 8×M8×80 |
| 5 | φ1150 | 640 | 80 | 430 | 605 | φ500 | 985 | 8×M10×95 |
| 6 | φ1250 | 820 | 80 | 472 | 662 | φ600 | 1026 | 8×M12×110 |
| 7 | φ1460 | 910 | 80 | 550 | 780 | φ700 | 1270 | 8×M12×110 |
| 8 | φ1610 | 1050 | 80 | 563 | 818 | φ800 | 1353 | 12×M12×110 |
| 10 | φ1840 | 1300 | 80 | 655 | 970 | φ1000 | 1560 | 12×M12×110 |
Note: a gravity backdraft damper or a motorised damper can be fitted at the air inlet. It is not included with the fan — please state it on the order, as it is purchased separately.




Roof exhaust ventilation
Roof smoke and exhaust ventilation
Roof ventilation of civil buildings
Roof exhaust for garages and warehouses, saving indoor space
A: The DWT-I is an axial roof fan: high airflow but lower pressure, suited to general ventilation. The DWT-II is a centrifugal roof fan: higher pressure and lower noise, suited to systems with higher duct resistance or stricter noise limits.
A: The DWT-II uses a double-layer hood: the outer hood shields rain while the inner hood guides the airflow. Combined with a flanged base, it effectively prevents rain from entering the building. We recommend fitting a waterproof sealing strip between the roof plinth and the fan base during installation.
A: The cylinder, hood and impeller are all moulded from FRP, giving good resistance to acids, alkalis and weathering. In corrosive gas atmospheres or open-air outdoor service, normal service life reaches 15 years or more.
A: Yes. The square base dimension B ranges from 430 mm to 1300 mm across 9 sizes, so the model can be matched to the roof opening. Special sizes can be customised by the factory — call +86 534 2555668.
A: Noise for the DWT-II roof fan ranges from 57 to 72 dB(A) and rises with model size. The smaller sizes (3# to 5#) are quieter; once installed on the roof, the floor slab attenuates the sound, so the fan is practically inaudible indoors and does not disturb office work.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.