The DeLENG DWT series low-noise roof fan is built in four versions — standard DWT, explosion-proof BDWT, anti-corrosion FDWT and anti-corrosion explosion-proof HDWT — in sizes 3# to 24#, with low noise, high efficiency and resistance to corrosion and high temperature, for power plants, rubber plants, large industrial buildings and commercial buildings.

The DeLENG DWT series low-noise roof fan is used mainly for ventilation and air exchange in large industrial buildings such as large thermal power plants, nuclear power plants and rubber plants, and in commercial buildings. By the gas handled it is divided into the DWT standard ventilation series, the BDWT explosion-proof series, the FDWT anti-corrosion series and the HDWT anti-corrosion explosion-proof series.
The fan is characterised by low noise, high efficiency, reliable performance, corrosion resistance, high-temperature resistance and safe explosion-proof construction. The anti-corrosion roof fan has passed the test of the National Explosion-proof Electrical Products Quality Supervision and Inspection Centre and holds an explosion-proof electrical production licence, giving a safety guarantee for ventilation in special industries handling flammable and explosive gases.
Three core components, quality you can see
| Model | Impeller dia. (mm) | Air volume (m³/h) | Static pressure (Pa) | Speed (r/min) | Motor power (kW) | Noise (dB) |
|---|---|---|---|---|---|---|
| 3 | 300 | 3300 | 181 | 2850 | 0.37 | 66 |
| 3000 | 206 | |||||
| 2600 | 232 | |||||
| 1650 | 62 | 1450 | 0.06 | 52 | ||
| 1560 | 66 | |||||
| 1450 | 72 | |||||
| 4 | 400 | 7450 | 193 | 2850 | 0.75 | 69 |
| 6350 | 230 | |||||
| 5300 | 250 | |||||
| 5700 | 176 | 1450 | 0.55 | 67 | ||
| 5400 | 184 | |||||
| 4580 | 190 | |||||
| 5 | 500 | 8000 | 135 | 1450 | 0.55 | 68 |
| 7000 | 162 | |||||
| 5600 | 191 | |||||
| 7000 | 113 | 960 | 0.37 | 63 | ||
| 6700 | 122 | |||||
| 6400 | 131 | |||||
| 6000 | 88 | 720 | 0.25 | 58 | ||
| 5000 | 92 | |||||
| 4100 | 96 | |||||
| 6 | 600 | 15000 | 232 | 1450 | 1.5 | 73 |
| 14000 | 251 | |||||
| 13000 | 267 | |||||
| 11000 | 168 | 960 | 1.1 | 67 | ||
| 10000 | 183 | |||||
| 9100 | 193 | |||||
| 8500 | 111 | 720 | 0.55 | 62 | ||
| 8000 | 127 | |||||
| 7600 | 136 | |||||
| 7 | 700 | 17500 | 165 | 960 | 1.5 | 69 |
| 15000 | 201 | |||||
| 12500 | 212 | |||||
| 12000 | 141 | 720 | 0.75 | 63 | ||
| 11000 | 163 | |||||
| 9200 | 177 | |||||
| 9300 | 83 | 560 | 0.55 | 59 | ||
| 8500 | 94 | |||||
| 7200 | 102 | |||||
| 8 | 800 | 27000 | 175 | 960 | 2.2 | 72 |
| 25000 | 207 | |||||
| 23000 | 228 | |||||
| 20000 | 129 | 720 | 1.5 | 66 | ||
| 18000 | 154 | |||||
| 16000 | 167 | |||||
| 15750 | 78 | 560 | 0.75 | 63 | ||
| 14500 | 96 | |||||
| 12250 | 121 | |||||
| 9 | 900 | 34500 | 202 | 960 | 3.0 | 76 |
| 29000 | 236 | |||||
| 24000 | 256 | |||||
| 32000 | 126 | 720 | 2.2 | 73 | ||
| 28000 | 156 | |||||
| 24000 | 177 | |||||
| 24000 | 102 | 560 | 1.1 | 67 | ||
| 21500 | 118 | |||||
| 18600 | 126 | |||||
| 10 | 1000 | 50000 | 251 | 960 | 5.5 | 81 |
| 45000 | 286 | |||||
| 39000 | 317 | |||||
| 46000 | 141 | 720 | 3.0 | 76 | ||
| 40000 | 167 | |||||
| 35000 | 183 | |||||
| 28000 | 111 | 560 | 1.5 | 69 | ||
| 24000 | 125 | |||||
| 20000 | 133 | |||||
| 11.2 | 1120 | 56900 | 253 | 960 | 5.5 | 82 |
| 49500 | 296 | |||||
| 40400 | 322 | |||||
| 52500 | 138 | 720 | 3.0 | 77 | ||
| 45000 | 169 | |||||
| 40000 | 183 | |||||
| 32000 | 111 | 560 | 1.5 | 69 | ||
| 28000 | 128 | |||||
| 25000 | 142 |
Technical parameters for sizes 12#~24# (with installation angle)
| Model | Impeller dia. (mm) | Installation angle | Air volume (m³/h) | Static pressure (Pa) | Speed (r/min) | Motor power (kW) | Noise (dB) |
|---|---|---|---|---|---|---|---|
| 12 | 1200 | 22° | 57000 | 196 | 720 | 5.5 | 73 |
| 19° | 50000 | 205 | |||||
| 16° | 44000 | 209 | |||||
| 27° | 42000 | 126 | 560 | 3.0 | 67 | ||
| 24° | 37500 | 134 | |||||
| 21° | 33000 | 148 | |||||
| 14 | 1400 | 17° | 76700 | 250 | 720 | 7.5 | 77 |
| 15° | 68000 | 261 | |||||
| 13° | 57500 | 268 | |||||
| 22° | 69000 | 159 | 480 | 4.0 | 69 | ||
| 20° | 60000 | 169 | |||||
| 18° | 51500 | 175 | |||||
| 15 | 1500 | 19° | 88500 | 195 | 720 | 7.5 | 78 |
| 17° | 80000 | 203 | |||||
| 15° | 70000 | 208 | |||||
| 23° | 74750 | 149 | 480 | 4.0 | 70 | ||
| 21° | 65000 | 158 | |||||
| 19° | 55800 | 165 | |||||
| 16 | 1600 | 20° | 107500 | 235 | 720 | 11 | 79 |
| 18° | 95000 | 248 | |||||
| 16° | 81500 | 256 | |||||
| 27° | 61000 | 131 | 320 | 4.0 | 70 | ||
| 25° | 52500 | 152 | |||||
| 23° | 42600 | 167 | |||||
| 18 | 1800 | 17° | 129300 | 261 | 720 | 15 | 80 |
| 15° | 112500 | 276 | |||||
| 13° | 96450 | 287 | |||||
| 23° | 96250 | 122 | 480 | 5.5 | 71 | ||
| 21° | 86150 | 136 | |||||
| 19° | 74300 | 143 | |||||
| 26° | 79150 | 115 | 320 | 4.0 | 66 | ||
| 23° | 71550 | 126 | |||||
| 20° | 62500 | 148 | |||||
| 20 | 2000 | 23° | 168700 | 215 | 480 | 15 | 78 |
| 21° | 150000 | 234 | |||||
| 19° | 131000 | 247 | |||||
| 21° | 125500 | 118 | 320 | 5.5 | 68 | ||
| 18° | 110000 | 121 | |||||
| 15° | 95200 | 132 | |||||
| 22 | 2200 | 18° | 201600 | 193 | 480 | 15 | 79 |
| 16° | 180000 | 205 | |||||
| 14° | 165000 | 210 | |||||
| 29° | 155000 | 135 | 320 | 7.5 | 71 | ||
| 27° | 120000 | 142 | |||||
| 25° | 119500 | 155 | |||||
| 24 | 2400 | 19° | 220800 | 212 | 480 | 18.5 | 84 |
| 17° | 198500 | 228 | |||||
| 15° | 176500 | 246 | |||||
| 26° | 175000 | 148 | 320 | 11 | 77 | ||
| 23° | 162000 | 164 | |||||
| 20° | 135000 | 188 | |||||
| 21° | 140000 | 150 | 220 | 7.5 | 70 | ||
| 18° | 120000 | 162 | |||||
| 15° | 85000 | 171 |
Note: the parameters above are compiled from fan performance test reports; the parameters confirmed by the manufacturer apply to the actual order.

φA outer cylinder diameter, φD impeller diameter, B/G/C/E/H part dimensions, n×M(d)×L anchor bolt specification; dimensions in mm
| Model | φA | φD | B | G | C | E | H | n×M(d)×L | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| 3 | φ650 | φ300 | 370 | 440 | 510 | 300 | 545 | 4×M8×250 | 15 |
| 4 | φ650 | φ400 | 470 | 550 | 630 | 340 | 585 | 4×M12×250 | 28 |
| 5 | φ1000 | φ500 | 570 | 660 | 750 | 390 | 715 | 4×M12×300 | 37 |
| 6 | φ1000 | φ600 | 670 | 770 | 870 | 440 | 765 | 4×M12×300 | 57 |
| 7 | φ1340 | φ700 | 800 | 900 | 1000 | 480 | 950 | 4×M12×300 | 85 |
| 8 | φ1340 | φ800 | 900 | 1000 | 1100 | 480 | 950 | 4×M12×350 | 124 |
| 9 | φ1650 | φ900 | 1000 | 1125 | 1250 | 480 | 950 | 4×M12×350 | 146 |
| 10 | φ1800 | φ1000 | 1100 | 1250 | 1400 | 480 | 1105 | 4×M12×350 | 216 |
| 12 | φ1800 | φ1200 | 1360 | 1510 | 1660 | 500 | 1125 | 8×M16×350 | 279 |
| 14 | φ2500 | φ1400 | 1560 | 1730 | 1900 | 600 | 1350 | 8×M16×400 | 357 |
| 15 | φ2500 | φ1500 | 1700 | 1870 | 2040 | 600 | 1350 | 8×M16×400 | 386 |
| 16 | φ3000 | φ1600 | 1800 | 1980 | 2160 | 600 | 1450 | 8×M16×450 | 397 |
| 18 | φ3000 | φ1800 | 2000 | 2200 | 2400 | 600 | 1450 | 8×M18×450 | 562 |
| 20 | φ3400 | φ2000 | 2200 | 2400 | 2600 | 600 | 1450 | 8×M20×450 | 721 |
| 22 | φ4200 | φ2200 | 2400 | 2600 | 2800 | 600 | 1500 | 8×M20×450 | 756 |
| 24 | φ4200 | φ2400 | 2600 | 2800 | 3000 | 600 | 1500 | 8×M20×450 | 856 |
Roof exhaust and air exchange for power plants, rubber plants and chemical plants
Roof ventilation for shopping malls, gymnasiums and office buildings
BDWT / HDWT explosion-proof types for chemical and paint-spraying workshops
Electroplating, pickling and humid coastal sites — anti-corrosion type





A: DWT is the standard version (FRP construction); BDWT is the explosion-proof version with an explosion-proof motor, for flammable and explosive gas atmospheres; FDWT is the anti-corrosion version with enhanced anti-corrosion treatment; HDWT is the anti-corrosion explosion-proof version, combining both protections.
A: The largest size in the DWT series is 24# with an impeller diameter of 2400 mm; maximum air volume reaches 220,800 m³/h and maximum weight is 856 kg, for ventilation of large industrial buildings.
A: FRP fans are light, corrosion resistant and do not rust, so they suit corrosive gas or humid environments; steel fans are stronger but rust easily. This series is moulded entirely in FRP, giving a long outdoor service life.
A: A gravity backdraft damper or a motorised damper can be fitted at the air inlet (purchased separately); it closes automatically when the fan stops, preventing rain and cold air from flowing back. Simply state this on the order.
Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer
A genuine source factory with in-house R&D, so the price stays genuinely competitive.
Self-inspected and tested unit by unit, which is why buyers trust us.
Ample stock and large ready quantities, so supply capacity is strong.
Sample-based customisation and non-standard machining — call us to discuss.