Home›Products ›Roof Fans ›DWT FRP Roof Fan (Anti-corrosion, Explosion-proof)

DWT FRP Roof Fan (Anti-corrosion, Explosion-proof)

DeLENG · factory direct supply

DWT FRP Roof Fan

The DeLENG DWT series low-noise roof fan is built in four versions — standard DWT, explosion-proof BDWT, anti-corrosion FDWT and anti-corrosion explosion-proof HDWT — in sizes 3# to 24#, with low noise, high efficiency and resistance to corrosion and high temperature, for power plants, rubber plants, large industrial buildings and commercial buildings.

22 model sizes 3#~24#4 versions DWT/BDWT/FDWT/HDWTExd II BT4 certified
DWT FRP roof fan DeLENG

Product introduction

The DeLENG DWT series low-noise roof fan is used mainly for ventilation and air exchange in large industrial buildings such as large thermal power plants, nuclear power plants and rubber plants, and in commercial buildings. By the gas handled it is divided into the DWT standard ventilation series, the BDWT explosion-proof series, the FDWT anti-corrosion series and the HDWT anti-corrosion explosion-proof series.

The fan is characterised by low noise, high efficiency, reliable performance, corrosion resistance, high-temperature resistance and safe explosion-proof construction. The anti-corrosion roof fan has passed the test of the National Explosion-proof Electrical Products Quality Supervision and Inspection Centre and holds an explosion-proof electrical production licence, giving a safety guarantee for ventilation in special industries handling flammable and explosive gases.

Key features

220,000 m³/h
Max air volume, size 24#
52 dB(A)
Min. noise, small sizes
FRP
Anti-corrosion, weatherproof, rainproof
Exd II BT4
National explosion-proof certified

Product details

Three core components, quality you can see

DWT roof fan anti-corrosion impeller
Anti-corrosion impeller
Thickened, reinforced FRP impeller in anti-corrosion material, with a multi-blade design for low noise and strong airflow.
DWT roof fan pure copper motor
Pure copper motor
High power and high-temperature resistance, low heat and low energy consumption, with reliable bearings for a long service life and good heat dissipation.
DWT roof fan anti-corrosion cylinder
Anti-corrosion cylinder
Thickened FRP cylinder: corrosion resistant, high strength, waterproof and rainproof.

DWT / BDWT / FDWT / HDWT Series Roof Fan Technical Parameters

Model Impeller dia. (mm) Air volume (m³/h) Static pressure (Pa) Speed (r/min) Motor power (kW) Noise (dB)
3 300 3300 181 2850 0.37 66
3000 206
2600 232
1650 62 1450 0.06 52
1560 66
1450 72
4 400 7450 193 2850 0.75 69
6350 230
5300 250
5700 176 1450 0.55 67
5400 184
4580 190
5 500 8000 135 1450 0.55 68
7000 162
5600 191
7000 113 960 0.37 63
6700 122
6400 131
6000 88 720 0.25 58
5000 92
4100 96
6 600 15000 232 1450 1.5 73
14000 251
13000 267
11000 168 960 1.1 67
10000 183
9100 193
8500 111 720 0.55 62
8000 127
7600 136
7 700 17500 165 960 1.5 69
15000 201
12500 212
12000 141 720 0.75 63
11000 163
9200 177
9300 83 560 0.55 59
8500 94
7200 102
8 800 27000 175 960 2.2 72
25000 207
23000 228
20000 129 720 1.5 66
18000 154
16000 167
15750 78 560 0.75 63
14500 96
12250 121
9 900 34500 202 960 3.0 76
29000 236
24000 256
32000 126 720 2.2 73
28000 156
24000 177
24000 102 560 1.1 67
21500 118
18600 126
10 1000 50000 251 960 5.5 81
45000 286
39000 317
46000 141 720 3.0 76
40000 167
35000 183
28000 111 560 1.5 69
24000 125
20000 133
11.2 1120 56900 253 960 5.5 82
49500 296
40400 322
52500 138 720 3.0 77
45000 169
40000 183
32000 111 560 1.5 69
28000 128
25000 142

Technical parameters for sizes 12#~24# (with installation angle)

Model Impeller dia. (mm) Installation angle Air volume (m³/h) Static pressure (Pa) Speed (r/min) Motor power (kW) Noise (dB)
12 1200 22° 57000 196 720 5.5 73
19° 50000 205
16° 44000 209
27° 42000 126 560 3.0 67
24° 37500 134
21° 33000 148
14 1400 17° 76700 250 720 7.5 77
15° 68000 261
13° 57500 268
22° 69000 159 480 4.0 69
20° 60000 169
18° 51500 175
15 1500 19° 88500 195 720 7.5 78
17° 80000 203
15° 70000 208
23° 74750 149 480 4.0 70
21° 65000 158
19° 55800 165
16 1600 20° 107500 235 720 11 79
18° 95000 248
16° 81500 256
27° 61000 131 320 4.0 70
25° 52500 152
23° 42600 167
18 1800 17° 129300 261 720 15 80
15° 112500 276
13° 96450 287
23° 96250 122 480 5.5 71
21° 86150 136
19° 74300 143
26° 79150 115 320 4.0 66
23° 71550 126
20° 62500 148
20 2000 23° 168700 215 480 15 78
21° 150000 234
19° 131000 247
21° 125500 118 320 5.5 68
18° 110000 121
15° 95200 132
22 2200 18° 201600 193 480 15 79
16° 180000 205
14° 165000 210
29° 155000 135 320 7.5 71
27° 120000 142
25° 119500 155
24 2400 19° 220800 212 480 18.5 84
17° 198500 228
15° 176500 246
26° 175000 148 320 11 77
23° 162000 164
20° 135000 188
21° 140000 150 220 7.5 70
18° 120000 162
15° 85000 171

Note: the parameters above are compiled from fan performance test reports; the parameters confirmed by the manufacturer apply to the actual order.

DWT Roof Fan Outline and Installation Dimensions

DWT roof fan outline dimension drawing

DWT Roof Fan Specification and Installation Dimension Table (sizes 3-24)

φA outer cylinder diameter, φD impeller diameter, B/G/C/E/H part dimensions, n×M(d)×L anchor bolt specification; dimensions in mm

Model φA φD B G C E H n×M(d)×L Weight (kg)
3 φ650 φ300 370 440 510 300 545 4×M8×250 15
4 φ650 φ400 470 550 630 340 585 4×M12×250 28
5 φ1000 φ500 570 660 750 390 715 4×M12×300 37
6 φ1000 φ600 670 770 870 440 765 4×M12×300 57
7 φ1340 φ700 800 900 1000 480 950 4×M12×300 85
8 φ1340 φ800 900 1000 1100 480 950 4×M12×350 124
9 φ1650 φ900 1000 1125 1250 480 950 4×M12×350 146
10 φ1800 φ1000 1100 1250 1400 480 1105 4×M12×350 216
12 φ1800 φ1200 1360 1510 1660 500 1125 8×M16×350 279
14 φ2500 φ1400 1560 1730 1900 600 1350 8×M16×400 357
15 φ2500 φ1500 1700 1870 2040 600 1350 8×M16×400 386
16 φ3000 φ1600 1800 1980 2160 600 1450 8×M16×450 397
18 φ3000 φ1800 2000 2200 2400 600 1450 8×M18×450 562
20 φ3400 φ2000 2200 2400 2600 600 1450 8×M20×450 721
22 φ4200 φ2200 2400 2600 2800 600 1500 8×M20×450 756
24 φ4200 φ2400 2600 2800 3000 600 1500 8×M20×450 856

Applications

I

Industrial buildings

Roof exhaust and air exchange for power plants, rubber plants and chemical plants

C

Commercial buildings

Roof ventilation for shopping malls, gymnasiums and office buildings

E

Explosive atmospheres

BDWT / HDWT explosion-proof types for chemical and paint-spraying workshops

C

Corrosive environments

Electroplating, pickling and humid coastal sites — anti-corrosion type

Product photos

DWT roof fan finished unit in workshop
DWT roof fan side view in workshop
DWT roof fan impeller guard in workshop
DWT roof fan internal structure in workshop
DWT roof fan hood in workshop

Frequently asked questions (FAQ)

Q: What is the difference between the DWT, BDWT, FDWT and HDWT versions?

A: DWT is the standard version (FRP construction); BDWT is the explosion-proof version with an explosion-proof motor, for flammable and explosive gas atmospheres; FDWT is the anti-corrosion version with enhanced anti-corrosion treatment; HDWT is the anti-corrosion explosion-proof version, combining both protections.

Q: What is the largest size available for roof fans?

A: The largest size in the DWT series is 24# with an impeller diameter of 2400 mm; maximum air volume reaches 220,800 m³/h and maximum weight is 856 kg, for ventilation of large industrial buildings.

Q: What is the difference between an FRP roof fan and a steel roof fan?

A: FRP fans are light, corrosion resistant and do not rust, so they suit corrosive gas or humid environments; steel fans are stronger but rust easily. This series is moulded entirely in FRP, giving a long outdoor service life.

Q: Does a roof fan need an air damper?

A: A gravity backdraft damper or a motorised damper can be fitted at the air inlet (purchased separately); it closes automatically when the fan stops, preventing rain and cold air from flowing back. Simply state this on the order.

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need DWT FRP Roof Fan?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top