Home›Products ›Cassette FCU ›DeLENG KM Series Standard 4-Way Cassette Fan Coil Unit

DeLENG KM Series Standard 4-Way Cassette Fan Coil Unit

DELENG HVAC · Direct from our Dezhou factory

DeLENG KM Series Standard 4-Way Cassette Fan Coil Unit
Natural Drainage · No Pump, No Control Board

Recessed into the ceiling with only the grille visible, four-way supply for an even temperature field, natural drainage with no control board or pump to wear out, large-diameter scroll centrifugal fan for quiet running, square panel with selectable pipe direction at site. Models FP-34KM-PI to FP-238KM-PI.

Four-way supplyRecessed in ceilingReliable natural drainageEven four-way airflowBrushless DC optional
DeLENG KM series standard 4-way cassette fan coil unit

Product introduction

The DeLENG cassette fan coil unit, also called a ceiling cassette unit, is designed for modern interior fit-out: it is neatly recessed into the ceiling with only the air outlets showing, so it looks good, saves space and is easy to service. Four-way supply makes the unit blend into the fit-out; the square panel allows the pipe direction to be chosen on site, so installation is flexible.

It uses a large-diameter vortex centrifugal fan for ultra-quiet running. Natural drainage means no pump, no control board and fewer wearing parts, so the unit runs more reliably. The square panel allows the pipe direction to be chosen on site and the wrapped panel corners make installation and maintenance easy. Multi-directional airflow makes the room temperature field more even; remote control auto swing, fresh-air intake and stainless flexible duct connections are optional.

Service hotline: 0534-2555668

Why choose the cassette fan coil unit

Recessed installation · four-way supply · reliable natural drainage · brushless DC optional

R

Recessed installation

Neatly recessed into the ceiling with only the outlets showing; it does not disturb the interior and suits any fit-out style.

F

Four-way supply

Wide-angle volute with a steel multi-blade centrifugal wheel: even airflow and smooth air circulation.

R

Reliable natural drainage

Natural drainage design with no control board or pump to wear out — more reliable running and lower maintenance cost.

B

Brushless DC optional

Optional brushless DC motor saves more than 30% energy and runs with low consumption and low noise.

KM series standard 4-way cassette fan coil unit technical parameters

FP-34KM-PI – FP-238KM-PI · natural drainage · 220-240V/1P/50Hz

Parameter Item FP-34KM-PI FP-51KM-PI FP-68KM-PI FP-85KM-PI FP-102KM-PI FP-136KM-PI FP-170KM-PI FP-204KM-PI FP-238KM-PI
Airflow m³/h High 340 510 680 850 1020 1360 1700 2040 2380
Medium 280 380 520 660 760 1020 1270 1530 1780
Low 180 280 340 430 510 680 850 1020 1190
Cooling capacity W High 1800 2700 3600 4500 5400 7200 9000 10800 12600
Medium 1500 2300 3060 3840 4600 6120 7660 9180 10720
Low 1350 1760 2350 2930 3510 4670 5850 7020 8190
Heating capacity W High 2700 4050 5400 6750 8100 10800 13500 16200 18900
Medium 2400 3450 4600 5750 6890 9170 11470 13770 16050
Low 2150 2460 3520 4290 5260 7020 8780 10550 12270
Noise dB(A) High 37 39 41 43 45 46 48 50 52
Medium 36 37 39 41 43 44 46 47 49
Low 34 35 37 39 39 40 42 45 46
Power supply — 220-240V / 1P / 50Hz
Input power W — 29 33 38 49 55 75 80 93 115
Working current A — 0.13 0.15 0.17 0.22 0.25 0.34 0.36 0.42 0.52
Control — Natural-drainage type; remote or wired controller optional
Water flow kg/h — 360 530 630 780 950 1260 1580 1890 2210
Water resistance kPa — 15 20 25 30 35 40 40 43 50
Max. working pressure — ≤1.6 MPa
Motor quantity — 1
Fan type — Low-noise centrifugal fan
Water connections — Rc 3/4" internal thread
Condensate drain — Φ20 mm
Unit dimensions L×W×H mm 575×575×390 741×741×400 830×830×420
Unit weight kg — 24 25 26 35 38 39 45 46 47
Panel L×W×H mm 650×650×35 850×850×38 950×950×40
Panel weight kg 2.5 4 7
Hanging installation L×W mm 625×275 790×340 880×380

Unit and panel installation dimensions (mm)

Installation dimension drawing of the standard 4-way cassette fan coil unit

All dimensions in mm; unit, panel and hanging holes shown

Applications · shop fronts and office space

S

Shop fronts

Four-way supply, no supply duct needed

O

Offices

Recessed in the ceiling, neat and space-saving

M

Meeting rooms

Even temperature, comfortable meetings

H

Hotel lobbies

Low-noise running that lifts the space

FAQ

Q: How much does a cassette fan coil unit cost?

A: We supply direct from the factory, so the price depends on the model and the options chosen — for example the base FP-51 model and the larger FP-136 model sit in different ranges, and the brushless DC version costs more. Call 0534-2555668 with your project list for a quotation.

Q: How large a service opening does a cassette unit need?

A: We recommend a 500×500 mm service opening below the side of the unit for filter replacement and drain-pan maintenance. The panel itself can be opened downwards, so routine filter cleaning does not need the service opening.

Q: Is a cassette fan coil unit noisy?

A: The DeLENG cassette unit uses a centrifugal fan with a pure copper motor; at low speed the noise is only 38 dB(A), comparable to a library, so it is perfectly suitable for hotels and offices.

Q: Cassette or horizontal concealed — which is better?

A: A 4-way cassette gives an even temperature without supply ducts, so it suits rooms with no ceiling or only a partial ceiling. A horizontal concealed unit needs supply ducts and suits a full ceiling. For shop fronts we recommend the cassette; for hotel guest rooms the horizontal concealed unit.

Third-party test report for this series (CMA / CNAS)
Nine models, FP-34WA to FP-238WA, tested by Guangdong Junxin Testing and the Jiangsu Institute of Product Quality Supervision and Inspection to GB/T 19232-2019 and related standards — all tested items pass. Ready for project approval and tender submissions.

Download test report →

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need KM Series Standard 4-Way Cassette Fan Coil Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top