Two-way outlet, recessed into the ceiling — the ideal terminal for long, narrow rooms. Copper coil and stainless construction, remote control with HD display, openable filter for easy cleaning. Supplied direct from our Dezhou factory, custom sizes available.

Cooling & heatingQuiet runningEnergy-savingStainless steel
DeLENG 2-way cassette fan coil unit, rectangular panel

Product introduction

The DeLENG 2-way cassette fan coil unit is a common terminal of a central air-conditioning system: it works with a chilled/hot water source to cool in summer and heat in winter. Products can be configured as horizontal concealed, vertical or cassette types to suit the site, and are widely used in hotels, office buildings, shopping malls, residences and other commercial premises.

The unit is compact and flexible to install; combined with a thermostat it gives independent temperature control and on-demand start/stop, balancing comfort and energy saving.

Service hotline: 0534-2555668

Why choose the 2-way cassette fan coil unit

Cooling & heating · quiet running · energy-saving · stainless steel

C

Cooling & heating

With a chilled/hot water source the unit cools in summer and heats in winter.

Q

Quiet running

Smooth, low-noise design, suitable for bedrooms, offices and hotels that need quiet.

E

Energy-saving

Efficient operation cuts the long-term running cost.

S

Stainless steel

Stainless material resists corrosion and is easy to clean — suited to damp areas or kitchens.

Product features · two-way supply for long, narrow spaces

Two-way outlet design · a perfect fit for long, narrow rooms

Openable filter, removable and washable

Openable filter · removable and washable

Rectangular panel for long and narrow spaces

Rectangular panel · fits long, narrow spaces

Remote control with HD display

Remote control · precise temperature, HD display

2-way cassette fan coil unit technical parameters

Standard GB/T 19232-2019

Model Item FP-51KM2 FP-68 FP-85 FP-102 FP-136
Cooling Cooling capacity kW 2.7 3.8 4.5 5.4 7.2
Water flow L/h 520 620 776 930 1,245
Water resistance kPa 10 11 13 16 20
Heating Heating capacity kW 4.05 5.5 6.7 8.0 10.8
Fan Type Centrifugal fan wheel
Wheel quantity 2 2 2 2 2
Electrical Power supply V/Ph/Hz 220V/1Ph/50Hz
Input power W 50 64 70 85 110
Running current A 0.23 0.29 0.31 0.38 0.49
Airflow (H/M/L) m³/h m³/h 510/390/260 680/520/400 850/640/490 1020/765/600 1360/1050/800
Noise dB(A) 39 42 43 45 46
Control — Remote control (wired controller optional)
Weight kg — 35.5 36 36.5 37 37.5
Unit dimensions L×W×H mm mm 1259 × 680 × 340
Panel dimensions mm mm 1240 × 680 × 30
Hanging hole pitch mm mm 1172 × 475
Packing dimensions mm mm 1270 × 720 × 390
Water connection Inlet DN20
Outlet DN20

Installation · outlet panel

Fit the outlet panel as follows so that it matches the indoor unit duct

Installation dimension drawing of the 2-way cassette fan coil unit

Installation dimension drawing (mm)

Outlet panel installation steps

1. Take out the panel, plug the stepper-motor lead and the display board lead on the panel into the matching leads from the electrical box, then tidy the connected leads.

2. Remove the grille and the filter.

3. Align the panel screw holes with the matching threaded positions on the indoor unit, fit the panel over it, and screw any two diagonally opposite M6×30 bolts with plain washers into the main unit (screwed in, not tightened).

4. Fit the other two M6×30 bolts with plain washers and screw them into the indoor unit through the panel holes.

5. Adjust the position and orientation of the panel so that its outlet frame matches the duct of the indoor unit drain pan, then tighten the bolts so the panel fits tightly against the indoor unit.

6. Refit the intake grille by reversing the steps used to remove the panel cover and grille.

Applications

C

Commercial

Shops, stores and other commercial ventilation and air conditioning

H

Hotels

Guest rooms and corridors, fresh air and air conditioning

S

Supermarkets

Fresh air and ventilation in stores and supermarkets

O

Offices

Quiet air supply for offices and meeting rooms

FAQ

Q: Where is this 2-way cassette fan coil unit used?

A: In commercial, hotel, supermarket and similar HVAC ventilation applications; DeLENG in Dezhou, as the source factory, can provide a matching solution for the actual needs of the project.

Q: Can the size and specification be customised?

A: Yes. The unit supports non-standard customisation to project drawings — size, material, surface finish and so on can all be selected as required. Send us your project parameters and we will confirm.

Q: Are you the source factory?

A: Yes. Dezhou DeLENG Air Conditioning Co., Ltd. is a source manufacturer of HVAC equipment: we produce and sell directly, with no middleman, and have our own design and production capability.

Q: What about stock and delivery?

A: DeLENG is a source factory in Dezhou, Shandong, with stock on hand and fast delivery, and we support customisation from samples. Call 0534-2555668 for selection advice and lead times.

Third-party test report for this series (CMA / CNAS)
Nine models, FP-34WA to FP-238WA, tested by Guangdong Junxin Testing and the Jiangsu Institute of Product Quality Supervision and Inspection to GB/T 19232-2019 and related standards — all tested items pass. Ready for project approval and tender submissions.

Download test report →

Related products

Why choose DeLENG?

Dezhou DeLENG Air Conditioning Co., Ltd. · HVAC equipment manufacturer

01

Factory direct

A genuine source factory with in-house R&D, so the price stays genuinely competitive.

02

Quality assurance

Self-inspected and tested unit by unit, which is why buyers trust us.

03

Stable supply

Ample stock and large ready quantities, so supply capacity is strong.

04

Custom manufacturing

Sample-based customisation and non-standard machining — call us to discuss.

Need 2-Way Cassette Fan Coil Unit?
Send your project parameters — the DeLENG technical team selects for you free of charge, factory direct supply, custom sizes available.
Contact us now+86 534 2555668
Scroll to Top